Editorial Type:
Article Category: Research Article
 | 
Online Publication Date: 01 Jan 2009

Two-year Water Degradation of Self-etching Adhesives Bonded to Bur Ground Enamel

and
Page Range: 732 – 740
DOI: 10.2341/09-020-L
ERRATUM TO THIS ARTICLE
Save
Download PDF

SUMMARY

To evaluate the effect of water storage on the microshear bond strength to ground enamel of three “all-in-one” self-etch adhesives: Futurabond DC, Clearfil S Tri Bond and Hybrid bond; a self-etching primer; Clearfil SE Bond and an etch-and-rinse adhesive system, Admira Bond. Sixty human molars were used. The root of each tooth was removed and the crown was sectioned into two halves. The convex enamel surfaces were reduced by polishing on silicon paper to prepare a flat surface that was roughened with a parallel-sided diamond bur with abundant water for five seconds. The bonding systems were applied on this surface. Prior to adhesive curing, a hollow cylinder (2.0 mm in height/0.75 mm in internal diameter) was placed on the treated surfaces and cured. A resin composite was then inserted into the tube and cured. For each adhesive, two procedures were carried out: A—the specimens were kept in water for 24 hours, then the tube was removed and the microshear bond strength was determined in a universal testing machine at a crosshead speed of 0.5 mm/minute; B—the specimens were stored in water for two-years before microshear testing. The fractured surface of the bonded specimens after each test procedure was examined by SEM. For the 24-hour control, there was no significant difference in bond strength between the tested adhesives. After two years of water storage, the bond strength of Admira Bond, Clearfil SE Bond and Futurabond DC decreased, but the reduction was not significantly different from that of 24 hours. For Clearfil S Tri Bond and Hybrid Bond, the bond strengths were significantly reduced compared to their 24-hour results.

INTRODUCTION

From the perspective of ease of handling, adhesives based on self-etching primers are preferred above total-etch systems. However, for the bond to enamel, the bonding quality in terms of bond strength values is not as consistent as that reported for the same products to dentin. Some authors reported that the bond strength of self-etching primers is inferior to that obtained with adhesive systems utilizing phosphoric acid as a surface conditioner.1–5 Conversely, other studies that tested composite-to-enamel bond strength with self-etching adhesive systems have reported values as high as 20 to 30 MPa,6–8 being in the same range as that reported on phosphoric acid-etched enamel. Regarding in-vitro microleakage experiments, self-etching adhesive systems were found to be comparable to those with separate etchants with respect to dentin marginal leakage but less effective at the enamel site.9–11 The reduced effectiveness in adhesion to enamel of some self-etching products has been attributed to the relative mild acidity of the primers, while strong self-etchants are said to produce a more effective enamel etch than mild agents.12

The self-etching primer can simultaneously cause both acid-conditioning and priming in one step. These adhesive systems eliminate the separate steps of acid etching and water rinsing, thus simplifying bonding procedures. Such simplification may reduce the technical errors that often follow the use of total-etch adhesives, such as over-etching, over-wetting or over-drying of the prepared tooth surface.

Whether these newer products produce the same superior margins along enamel walls as their etch and rinse predecessors is of critical importance. Representative clinical studies have not demonstrated significant differences in the marginal discoloration of non-retentive Class V restorations between self-etching primers, self-etching adhesives and etch-and-rinse adhesives.13–15

Recently, the microshear bond test was introduced as an alternative to the microtensile bond test.16 The microshear bond test involves the application of a loading force by means of a blade from a universal testing machine to a resin composite cylinder bonded to a substrate disc. Advantages of the microshear bond test include less demanding specimen collection and easier control of the bond test area by means of microbore tubes. Shimida and others modified the microshear bond test by employing a looped orthodontic wire rather than a blade.17

In addition, different artificial aging techniques were used in order to predict the clinical performance of tested materials. The most commonly used artificial aging technique is water storage. In this technique, the bonded specimens are stored in fluid at 37°C for a specific period. This period may vary from a few months18 up to four-to-five years19–21 or longer. Most of these studies report significant decreases in bond strengths, even after relatively short storage periods.22–28 The decrease in bonding effectiveness after water storage was supposed to be caused by degradation of interface components by hydrolysis (mainly resin and/or collagen). Also, water can infiltrate and decrease the mechanical properties of the polymer matrix by swelling and reducing the frictional forces between the polymer chains. This causes plasticization of the resin, which makes it weaker.29–30

The current study was designed to evaluate the influence of water storage on the microshear bond strength of one total-etch adhesive and four self-etching adhesives to ground enamel. The null hypothesis was that there was no difference between the self-etching materials and the total-etch adhesive in their bond strengths to ground enamel when stored in water.

METHODS AND MATERIALS

Four commercial self-etching bond systems (Table 1) were used in the current study: Futurabond DC (Voco, Cuxhaven, Germany), Clearfil S Tri Bond (Kuraray Medical, Inc, Tokyo, Japan), Hybrid Bond (Sun Medical, Moriyama, Japan) and Clearfil SE Bond (Kuraray Medical, Inc). The first three are “all-in-one” adhesives, while the fourth is a self-etching primer to which a layer of adhesive is applied. The etch-and-rinse system Admira Bond (Voco) was used as a control.

Table 1 Chemical Composition of Tested Materials
Table 1

Microshear Bond Strength

Sixty caries-free human molars (gathered following informed consent approved by the Commission for Medical Ethics of the University) were used for the bonding tests. The teeth were washed under running water immediately after extraction and stored in 0.02% thymol solution until the experiment time, which was scheduled within one month after extraction. At that time, the root of each tooth was removed and the crown was sectioned into two halves by cutting parallel to the longitudinal axis and facial surface using a low speed Isomet saw (Buehler Ltd, Lake Bluff, IL, USA) under running water. The convex enamel surfaces on the outermost buccal or palatal slices were reduced up to 0.5 mm by gently polishing on 600 grit silicon carbide paper under running water to prepare a flat enamel surface. This surface was roughened with a parallel-sided medium-grit (100 μm) diamond bur (842, Komet, Lemgo, Germany) for five seconds with abundant water. The inner surface of the crown segment was also polished to create a flat surface on the dentin for ease of fixation during microshear testing. All the tooth-halves were randomly assigned; however, for each adhesive, the buccal and palatal sections were equally distributed. The bonding systems were then applied on the pre pared enamel surface of each half following the manufacturer's instructions (Table 1). Prior to irradiation of the bonding resin on each specimen, polyethylene micro-bore tubing 2.0 mm in height (Norton Performance Plastics, Granville, NY, USA) with an internal diameter of 0.75 mm was placed on the treated surfaces. After light irradiation with a halogen light source (Visulux curing unit, Vivadent, Schaan, Liechtenstein) for 20 seconds, a hybrid restorative composite from the same manufacturer was used. The composite was carefully inserted into the tubing lumens and irradiated for 40 seconds according to the manufacturer's instructions. The output of the light-curing unit was regularly checked to insure it was 500 mW/mm2.

The resin composites used were Grandio (Voco), Clearfil APX (Kuraray Medical, Inc) and Pecalux (Sun-Medical). The specimens were stored in water at 37°C for 24 hours. After removal from water, the tygon tubing around the composite cylinders was removed by gently cutting the tube into two hemi cylinders using a feather-edge blade. This procedure was done under stereomicroscope, and special caution was taken to avoid applying any stress to the bonded composite cylinders.

Two test procedures were carried out for each adhesive.

Procedure A: Specimens tested for microshear bond strength after 24 hours of water storage.

Procedure B: The specimens were kept in water containing 0.5% chloramine to prevent bacterial growth for two years, then the bond strength measurement was carried out. The water was replaced every three months. During replacement, the specimens were allowed to cool slowly to room temperature and the water was replaced.

For microshear testing, each tooth slice was attached to the testing apparatus (modified Ciucchi's jig, Pashley & others31) with a cyanoacrylate adhesive and tested in a universal testing machine (Instron, Corp, High Wycombe, UK). A thin steel wire (0.20 mm D) was looped flush between the load cell projection and the resin cylinder, making contact with the lower half-circle of the cylinder and touching the tooth surface. The force was applied at a crosshead speed of 0.5 mm/minute until failure. Care was taken to keep the composite cylinder in line with the center of the load cell and the wire loop, parallel to the load cell movement direction and the bonded surface, in order to maintain a shear stress orientation at the bonding interface. The maximum load at the time of failure was recorded. A total of 12 bond strength values was recorded for each adhesive. The types of failure were observed at 50× magnification and categorized as adhesive, cohesive or mixed.

Each adhesive system was applied according to the manufacturer's instructions.

Statistical Analysis: The bond strength was calculated and the data obtained for the five subgroups were statistically analyzed using one-way ANOVA, followed by the Tukey-Kramer Multiple Comparison Test at a 5% confidence level.

Fracture Surfaces Observation

After microshear testing, the fractured surface of the specimen was inspected by a stereomicroscope at 50× magnification (Olympus, Tokyo, Japan) to evaluate the mode of failure. The mode of the failures was classified into cohesive in enamel or cohesive in resin, adhesive at the enamel/resin interface and mixed. In addition, for representative specimens of each test group, impressions of the fractured surfaces were made using a light-body polyvinylsiloxane impression material (Extrude, Kerr GmbH, Karlsruhe, Germany). The impressions were cast in epoxy resin (Epoxy Die), then mounted on aluminum stubs, sputter-coated with gold and observed by using SEM (Philips XL30, Eindhoven, The Netherlands) operating at 15 kV.

Morphological Study Using SEM

In addition, 20 enamel slices were prepared as mentioned, with four slices for each adhesive. After adhesive application, a resin composite was placed 2 mm thick to form a composite core. The slices were stored in water for 24 hours, after which two slices from each adhesive were kept in 0.1 N HCl for 24 hours to completely dissolve the enamel. The resulting composite replicas were examined using SEM, as mentioned for the adhesive-enamel interface. The other two slices for each adhesive were stored in water for two years before acid dissolution and SEM evaluation.

RESULTS

Microshear Bond Strength Test

After 24-hours of water storage, there were no significant differences in bond strength of the tested adhesives (Table 2). The bond strength of the total etch adhesive “Admira Bond” was slightly higher than that of the other materials. However, that difference was not significant (p>0.05).

Table 2 Microshear Bond Strength of the Tested Adhesives to Enamel (MPa ± SD)
Table 2

After two years of water storage, the bond strength of all the tested adhesives was reduced. For Admira Bond, Clearfil SE Bond and Futurabond DC, the reduction in bond strength was not significant (p>0.05). For Hybrid Bond and Clearfil S Tri Bond, the reduction was significant (p<0.05).

Figures 1a and 1b show the morphological interface between a total-etch adhesive, Admira Bond, and enamel. The enamel was completely removed by dissolving in HCL to show the resin penetration into enamel. Two types of resin penetration are evident: infiltration into and between interprismitic (IP) substances that are of different thicknesses and morphology. In addition, intraprismitic infiltration can be seen (IAP) as hollow porosities at all surfaces of the prisms. Figure 2a shows the interface between Futurabond DC and enamel, which is different from that with the etch-and-rinse system. The interprismitic diffusion (IP) was rather shallow and even absent in some locations. However, the intraprismitic diffusion (IAP) was evident in high magnification (Figure 2b). Many areas of nanometer resin diffusion were seen on the top surface of the prism.

Figure 1a and Figure 1b. The morphological interface between the total-etch adhesive Admira Bond and enamel. (The enamel was completely removed by dissolving in 0.1 N HCl for two hours to show the resin penetration into enamel). Two types of resin penetration are evident: infiltration into and between interprismitic (IP) substances that are of different thicknesses and morphology. In addition, interaprismitic infiltration can be seen (IAP) (Figure 1b).Figure 1a and Figure 1b. The morphological interface between the total-etch adhesive Admira Bond and enamel. (The enamel was completely removed by dissolving in 0.1 N HCl for two hours to show the resin penetration into enamel). Two types of resin penetration are evident: infiltration into and between interprismitic (IP) substances that are of different thicknesses and morphology. In addition, interaprismitic infiltration can be seen (IAP) (Figure 1b).Figure 1a and Figure 1b. The morphological interface between the total-etch adhesive Admira Bond and enamel. (The enamel was completely removed by dissolving in 0.1 N HCl for two hours to show the resin penetration into enamel). Two types of resin penetration are evident: infiltration into and between interprismitic (IP) substances that are of different thicknesses and morphology. In addition, interaprismitic infiltration can be seen (IAP) (Figure 1b).
Figure 1a and Figure 1b The morphological interface between the total-etch adhesive Admira Bond and enamel. (The enamel was completely removed by dissolving in 0.1 N HCl for two hours to show the resin penetration into enamel). Two types of resin penetration are evident: infiltration into and between interprismitic (IP) substances that are of different thicknesses and morphology. In addition, interaprismitic infiltration can be seen (IAP) (Figure 1b).

Citation: Operative Dentistry 34, 6; 10.2341/09-020-L

Figure 2a and Figure 2b. The interface between Futurabond DC and enamel. The interprismitic diffusion (IP) was rather shallow and even absent in some locations. However, the intraprismitic diffusion (IAP) was evident in high magnification (Figure 2b). Many areas of nanometer resin diffusion were seen on the top surface of the prism.Figure 2a and Figure 2b. The interface between Futurabond DC and enamel. The interprismitic diffusion (IP) was rather shallow and even absent in some locations. However, the intraprismitic diffusion (IAP) was evident in high magnification (Figure 2b). Many areas of nanometer resin diffusion were seen on the top surface of the prism.Figure 2a and Figure 2b. The interface between Futurabond DC and enamel. The interprismitic diffusion (IP) was rather shallow and even absent in some locations. However, the intraprismitic diffusion (IAP) was evident in high magnification (Figure 2b). Many areas of nanometer resin diffusion were seen on the top surface of the prism.
Figure 2a and Figure 2b The interface between Futurabond DC and enamel. The interprismitic diffusion (IP) was rather shallow and even absent in some locations. However, the intraprismitic diffusion (IAP) was evident in high magnification (Figure 2b). Many areas of nanometer resin diffusion were seen on the top surface of the prism.

Citation: Operative Dentistry 34, 6; 10.2341/09-020-L

Fracture Surface Observation

There were no pretest failures in any group. Overall, failures were predominately adhesive or mixed. The incidence of cohesive failures in composite was more common with increasing bond strength. The complete results are presented in Table 3.

Table 3 Failure Patterns of the Tested Adhesives to Ground Enamel After 24-hours and 2-year Water Storage
Table 3

After 24 hours of water storage, the fracture patterns of the bonded specimens were adhesive (61%) at the resin-enamel interface. Also, mixed types of failures were shown in 27% of the specimens, while 12% showed cohesive failure either in enamel or composite.

After two years of wear storage, failures were also mainly adhesive (72%). The mixed type of failure was seen in 27% of the specimens. Cohesive failure in composite was seen in 1% of the specimens. Figure 3 shows the fracture surface of the Admira Bond specimens after two-years of water storage. Resins were still present in the interprismitic substances as well as the top prism itself. Figure 4 shows the fracture surface of Hybrid Bond after two years of water storage. The resins were lost and the inter-prismitic spaces were visible. Also, the resins were lost from the prism itself.

Figure 3. Fracture surface of Admira Bond specimens after two years of water storage. Resins were still present in the interprismitic substances as well as the top prism itself.Figure 3. Fracture surface of Admira Bond specimens after two years of water storage. Resins were still present in the interprismitic substances as well as the top prism itself.Figure 3. Fracture surface of Admira Bond specimens after two years of water storage. Resins were still present in the interprismitic substances as well as the top prism itself.
Figure 3 Fracture surface of Admira Bond specimens after two years of water storage. Resins were still present in the interprismitic substances as well as the top prism itself.

Citation: Operative Dentistry 34, 6; 10.2341/09-020-L

Figure 4. Fracture surface of Hybrid Bond after two years of water storage. Resins were lost and interprismitic spaces are visible. Also, resins were lost from the prism itself.Figure 4. Fracture surface of Hybrid Bond after two years of water storage. Resins were lost and interprismitic spaces are visible. Also, resins were lost from the prism itself.Figure 4. Fracture surface of Hybrid Bond after two years of water storage. Resins were lost and interprismitic spaces are visible. Also, resins were lost from the prism itself.
Figure 4 Fracture surface of Hybrid Bond after two years of water storage. Resins were lost and interprismitic spaces are visible. Also, resins were lost from the prism itself.

Citation: Operative Dentistry 34, 6; 10.2341/09-020-L

DISCUSSION

In the current study, the effect of water storage on the bond strength of four self-etching adhesives and one total-etch adhesive to ground enamel was evaluated. Under clinical situations, cycling masticatory function has been reported to fatigue the integrity of the resin enamel bond, thereby permitting micro- or nanoleakage of the peripheral enamel seal.3233 In the current study, the bond strength tests were carried out using enamel from the different teeth. Care was taken to apply the adhesive to the enamel surfaces prepared to similar depths to minimize the effects of the enamel prism orientation and variation. The bond strength to transverse sections of enamel prisms has been found to be significantly higher than to longitudinal sections.3435

After 24 hours of water storage, the bond strength of tested self-etch adhesives showed a comparable bonding capability to enamel as to the total-etch systems. Other studies, however, suggest that the bond strength of self-etch adhesives to enamel is inferior.1–5 For the acid-etch systems, the primary mechanism of adhesion to enamel is based on micromechanical retention. When phosphoric acid is applied to enamel, a preferential dissolution of interprismitic enamel permits the creation of 1 μm wide resin tags between the enamel, as well as resin infiltration within the surface of prisms to produce enamel hybrid layers. Resin tags filling the microporous enamel surface have been considered to be of major importance in bonding to etched enamel.3637 For the self-etching adhesives, the self-etching primer dissolves the surface area of individual enamel crystallites and widens the intercrystallite spaces. In addition, dissolution along the C-axis of the crystallites was observed.38 A three-dimensional inter- and intracrystallite nanoretentive etching pattern is thereby created, while simultaneously promoting monomer infiltration. This etching pattern only produced resin infiltration into enamel to a depth of 0.6–0.7 μm.39 However, even this shallow resin penetration gave good resin–enamel bond strengths. The interprismitic resin tags that are typically observed in phosphoric acid-etched enamel were not seen when bonding with these self-etching primers, which are relatively weak. Apparently, resin infiltration between enamel crystallites creates nanometer-sized resin tags that can contribute to high resin-enamel bond strengths even in the absence of interprismitic resin tags. This resin-infiltrated enamel surface layer might be considered as the resin–enamel interdiffusion zone or hybrid layer.4041

After two years of water storage, the bond strength of all tested adhesives was reduced; however, such a difference was only significant in Clearfil S Tri Bond (Kuraray Medical, Inc) and Hybrid Bond (Kuraray Medical, Inc). Performance of the tested adhesives related to water storage may be dependent on the ability of individual components to resist deterioration by water storage and to the mechanism of achieving bonding to enamel.

Clearfil SE Bond (Kuraray Medical, Inc) is a two-step, mild self-etching primer-adhesive. The primer of Clearfil SE Bond contains 10-MDP as a functional monomer dissolved in HEMA and water to result in a pH of around 2. The primer of this material produced minimal changes in surface topography, resulting in a very superficial resin infiltration. Similar findings were also reported by Perdigão and others.39 In spite of such low minimal surface changes reported with Clearfil SE Bond, the bond strength was close to that reported with the etch and rise system after 24 hours. Also, the bond was stable after two years of water storage. Again, this was attributed to the inter- and intracrystallite hybridization of the enamel rather than dissolution and resin-tag formation.40 This was suggested to be further augmented by secondary bonds, which have formed between hydrophilic resins and enamel. Accordingly, enamel adhesion is believed to be a twofold mechanism. One is micro-mechanical interlocking and the other is a chemical interaction between functional monomers of adhesives and enamel.42 These bonding mechanisms could probably explain the favorable performance of SE Bond (Kuraray Medical, Inc) after two years of water storage.

Futurabond DC (Voco) showed a bond strength value of 29 ± 3.5 MPa after 24 hours of water storage. After two years of water storage, such value was 26 ± 2.4, which is not significantly different from the 24 hour ones. Futura-bond DC contains polyfunctional adhesive monomers (phosphoric acid modified methacrylate esters). These acid esters, when mixed with water, produced a pH value of 1.4.43 Accordingly, the smear layer was mobilized and the hydroxyl apatite was dissolved (demineralized), creating a retentive pattern on the enamel surface. During this process, the acids in the bonding agent are neutralized by hydroxyapatite in the tooth structure; that is, this process only runs until the acid is exhausted. Once the surface has been conditioned, the surface area was increased and bonding resin was penetrated into the etched pattern analogous to conventional etching with phosphoric acid, producing a retentive adhesion.44 Chemical bonding also takes place in the surface of the tooth structure due to complexation of the calcium by the adhesive.45

Hybrid Bond (Sun Medical) is an “all-in-one” adhesive that contains 4-META as an active monomer component. In an aqueous environment, this monomer is converted to the dicarboxylic acid 4-MET, which is the etching component of Hybrid Bond with a pH of around 1.46 This high acidity resulted in rather aggressive demineralization. Consequently, the underlying mechanism of bonding of Hybrid Bond is primarily diffusion-based, similar to that of the total-etch approach. Furthermore, the hydrophilic end of 4-MET offers the advantages of forming ionic bonds to the calcium in apatite.46 This bonding mechanism, which seems to encapsulate the apatite crystals with a relatively hydrophobic MMA bonding resin, may explain the excellent performance of this material at 24 hours. However, after two years of water storage, such bond mechanisms were unable to resist deterioration by water exposure. A possible reason for such findings could be the absence of coupling hydrophobic bonding agent. Rapid water sorption can occur via the hydrophilic and permeable adhesive layer.33

The chemical composition of Clearfil S Tri Bond (Kuraray Medical, Inc) was quite similar to Clearfil SE Bond (Kuraray Medical, Inc). On enamel, it also produced minimal changes in surface topography, resulting in a very superficial resin infiltration. In contrast to Clearfil SE bond, the material showed lower bond strength value. Again, this could be attributed to the absence of coupling hydrophobic bonding agent, which made such material behave as permeable membranes after polymerization.47

In the current study, only adhesives and resin composites from the same manufacturer were used. This eliminated the risk of incompatibility between any of the adhesives and a single resin composite. However, there is some evidence to indicate that different composites with different elastic moduli result in different bond strength outcomes. These should be taken into consideration during interpretation of the outcome of the current study. Future researchers should evaluate the effect of other degradation factors, for example, thermocycling on bond strength to enamel.

CONCLUSIONS

After 24 hours of water storage, the bond strength of self-etching adhesive systems to ground enamel are dependent on the type of adhesive. Some of these adhesives showed bond strength values comparable to that of etch-and-rinse systems. After two-years of water storage, the bond strength of the etch-and-rinse system was stable. For self-etch systems, all adhesives showed a reduction in bond strength that was significant for some materials.

References

  • 1
    Hara, A. T.
    ,
    C. M.Amaral
    ,
    L. A.Pimenta
    , and
    M. A.Sinhoreti
    . 1999. Shear bond strength of hydrophilic adhesive systems to enamel.American Journal of Dentistry12
    4
    :181184.
  • 2
    Miyazaki, M.
    ,
    N.Hirohata
    ,
    K.Takagaki
    ,
    H.Onose
    , and
    B. K.Moore
    . 1999. Influence of self-etching primer drying time on enamel bond strength of resin composites.Journal of Dentistry27
    3
    :203207.
  • 3
    Yoshiyama, M.
    ,
    T.Matsuo
    ,
    S.Ebisu
    , and
    D.Pashley
    . 1998. Regional bond strengths of self-etching/self-priming adhesive systems.Journal of Dentistry26
    7
    :609616.
  • 4
    Carvalho, R. M.
    ,
    C. A.Fernandes
    ,
    R.Villanueva
    ,
    L.Wang
    , and
    D. H.Pashley
    . 2001. Tensile strength of human dentin as a function of tubule orientation and density.Journal of Adhesive Dentistry3
    4
    :309314.
  • 5
    De Munck, J.
    ,
    M.Vargas
    ,
    J.Iracki
    ,
    K.Van Landuyt
    ,
    A.Poitevin
    ,
    P.Lambrechts
    , and
    B.Van Meerbeek
    . 2005. One-day bonding effectiveness of new self-etch adhesives to bur-cut enamel and dentin.Operative Dentistry30
    1
    :3949.
  • 6
    Hayakawa, T.
    ,
    K.Kikutake
    , and
    K.Nemoto
    . 1998. Influence of self-etching primer treatment on the adhesion of resin composite to polished dentin and enamel.Dental Materials14
    2
    :99105.
  • 7
    Van Landuyt, K. L.
    ,
    P.Kanumilli
    ,
    J.De Munck
    ,
    M.Peumans
    ,
    P.Lambrechts
    , and
    B.Van Meerbeek
    . 2006. Bond strength of a mild self-etch adhesive with and without prior acid-etching.Journal of Dentistry34
    1
    :7785.
  • 8
    Kanemura, N.
    ,
    H.Sano
    , and
    J.Tagami
    . 1999. Tensile bond strength to and SEM evaluation of ground and intact enamel surfaces.Journal of Dentistry27
    7
    :523530.
  • 9
    Carvalho, R. M.
    ,
    S. L.Santiago
    ,
    C. A.Fernandes
    ,
    B. I.Suh
    , and
    D. H.Pashley
    . 2000. Effects of prism orientation on tensile strength of enamel.Journal of Adhesive Dentistry2
    4
    :251257.
  • 10
    Urabe, I.
    ,
    S.Nakajima
    ,
    H.Sano
    , and
    J.Tagami
    . 2000. Physical properties of the dentin–enamel junction region.American Journal of Dentistry13
    3
    :129135.
  • 11
    Pradelle-Plasse, N.
    ,
    S.Nechad
    ,
    B.Tavernier
    , and
    P.Colon
    . 2001. Effect of dentin adhesives on the enamel-dentin/composite interfacial microleakage.American Journal of Dentistry14
    6
    :344348.
  • 12
    Pashley, D. H.
    and
    F. R.Tay
    . 2001. Aggressiveness of contemporary self-etching adhesives, Part II: Etching effects on unground enamel.Dental Materials17
    5
    :430444.
  • 13
    Kuboa, S.
    ,
    K.Kawasakib
    ,
    H.Yokotaa
    , and
    Y.Hayashi
    . 2006. Five-year clinical evaluation of two adhesive systems in non-carious cervical lesions.Journal of Dentistry34
    2
    :97105.
  • 14
    Turkun, S. L.
    2003. Clinical evaluation of a self-etching and a one-bottle adhesive system at two years.Journal of Dentistry31
    8
    :527534.
  • 15
    van Dijken, J. W.
    2004. Durability of three simplified adhesive systems in Class V non-carious cervical dentin lesions.American Journal of Dentistry17
    1
    :2732.
  • 16
    McDonough, W. G.
    ,
    J. M.Antonucci
    ,
    J.He
    ,
    Y.Shimada
    ,
    M. Y.Chiang
    ,
    G. E.Schumacher
    , and
    C. R.Schultheisz
    . 2002. A microshear test to measure bond strengths of dentin-polymer interfaces.Biomaterials23
    17
    :36033608.
  • 17
    Shimada, Y.
    ,
    D.Kikushima
    , and
    J.Tagami
    . 2002. Microshear bond strength of resin-bonding systems to cervical enamel.American Journal of Dentistry15
    6
    :373377.
  • 18
    Shono, Y.
    ,
    M.Terashita
    ,
    J.Shimada
    ,
    Y.Kozono
    ,
    R. M.Carvalho
    ,
    C. M.Russell
    , and
    D. H.Pashley
    . 1999. Durability of resin-dentin bonds.Journal of Adhesive Dentistry1
    3
    :211218.
  • 19
    Fukushima, T.
    ,
    Y.Inoue
    ,
    K.Miyazaki
    , and
    T.Itoh
    . 2001. Effect of primers containing N-methylolacrylamide or N-methylol-methacrylamide on dentin bond durability of a resin composite after 5 years.Journal of Dentistry29
    3
    :227234.
  • 20
    De Munck, J.
    ,
    B.Van Meerbeek
    ,
    Y.Yoshida
    ,
    S.Inoue
    ,
    K.Suzuki
    , and
    P.Lambrechts
    . 2004. Four-year water degradation of a glass-ionomer adhesive bonded to dentin.European Journal of Oral Science112
    1
    :7383.
  • 21
    Abdalla, A. I.
    and
    A. J.Feilzer
    . 2008. Four-year water degradation of a total-etch and two self-etching adhesives bonded to dentin.Journal of Dentistry36
    8
    :611617.
  • 22
    Kato, G.
    and
    N.Nakabayashi
    . 1998. The durability of adhesion to phosphoric acid etched, wet dentin substrates.Dental Materials14
    5
    :347352.
  • 23
    Kitasako, Y.
    ,
    M. F.Burrow
    ,
    T.Nikaido
    , and
    J.Tagami
    . 2000. The influence of storage solution on dentin bond durability of resin cement.Dental Materials16
    1
    :16.
  • 24
    Armstrong, S. R.
    ,
    J. C.Keller
    , and
    D. B.Boyer
    . 2001. The influence of water storage and C-factor on the dentin-resin composite microtensile bond strength and debonded pathway utilizing a filled and unfilled adhesive resin.Dental Materials17
    3
    :268276.
  • 25
    Armstrong, S. R.
    ,
    M. A.Vargas
    ,
    Q.Fang
    , and
    J. E.Laffoon
    . 2003. Microtensile bond strength of a total-etch 3-step, total-etch 2-step, self-etch 2-step, and a self-etch 1-step dentin bonding system through 15-month water storage.Journal of Adhesive Dentistry5
    1
    :4756.
  • 26
    Meiers, J. C.
    and
    D.Young
    . 2001. Two-year composite/dentin bond stability.American Journal of Dentistry14
    3
    :141144.
  • 27
    Burrow, M. F.
    ,
    M.Satoh
    , and
    J.Tagami
    . 1996. Dentin bond durability after three years using a dentin bonding agent with and without priming.Dental Materials12
    5
    :302307.
  • 28
    Giannini, M.
    ,
    C. A. M.Seixas
    ,
    A. F.Reis
    , and
    L. A. F.Pimenta
    . 2003. Six-month storage-time evaluation of one-bottle adhesive systems to dentin.Journal of Esthetic Restorative Dentistry15
    1
    :438. discussion 49.
  • 29
    Ferracane, J. L.
    ,
    H. X.Berge
    , and
    J. R.Condon
    . 1998. In vitro aging of dental composites in water—effect of degree of conversion, filler volume, and filler/matrix coupling.Journal of Biomedical and Materials Research42
    3
    :465472.
  • 30
    Santerre, J. P.
    ,
    L.Shajii
    , and
    B. W.Leung
    . 2001. Relation of dental composite formulations to their degradation and the release of hydrolyzed polymeric-resin-derived products.Critical Reviews in Oral Biology and Medicine12
    2
    :136151.
  • 31
    Pashley, D. H.
    ,
    R. M.Carvalho
    ,
    H.Sano
    ,
    M.Nakajima
    ,
    M.Yoshiyama
    ,
    Y.Shono
    ,
    C. A.Fernandes
    , and
    F.Tay
    . 1999. The microtensile bond test: A review.Journal of Adhesive Dentistry1
    4
    :299309.
  • 32
    Frankenberger, R.
    and
    F. R.Tay
    . 2005. Self-etch vs etch-and-rinse adhesives: Effect of thermo-mechanical fatigue loading on marginal quality of bonded resin composite restorations.Dental Materials21
    5
    :397412.
  • 33
    Hashimoto, M.
    ,
    H.Ohno
    ,
    M.Kaga
    ,
    K.Endo
    ,
    H.Sano
    , and
    H.Oguchi
    . 2000. In vivo degradation of resin-dentin bonds in humans over 1 to 3 years.Journal of Dental Research79
    6
    :13851391.
  • 34
    Munechika, T.
    ,
    K.Suzuki
    ,
    M.Nishiyama
    ,
    M.Ohashi
    , and
    K.Horie
    . 1984. A comparison of the tensile bond strengths of composite resins to longitudinal and transverse sections of enamel prisms in human teeth.Journal of Dental Research63
    8
    :10791082.
  • 35
    Shimada, Y.
    and
    J.Tagami
    . 2003. Effects of regional enamel and prism orientation on resin bonding.Operative Dentistry28
    1
    :2027.
  • 36
    Ibarra, G.
    ,
    M. A.Vargas
    ,
    S. R.Armstrong
    , and
    D. S.Cobb
    . 2002. Micro-tensile bond strength of self-etch adhesives to ground and unground enamel.Journal of Adhesive Dentistry4
    2
    :115124.
  • 37
    Miyazaki, M.
    ,
    K.Hinoura
    ,
    G.Honjo
    , and
    H.Onose
    . 2002. Effect of self-etching primer application method on enamel bond strength.American Journal of Dentistry15
    6
    :412416.
  • 38
    Gregoire, G.
    and
    Y.Ahmed
    . 2007. Evaluation of the enamel etching capacity of six contemporary self-etching adhesives.Journal of Dentistry35
    5
    :388397.
  • 39
    Perdigão, J.
    ,
    L.Lopes
    ,
    P.Lambrechts
    ,
    J.Leitao
    ,
    B.Van Meerbeek
    , and
    G.Vanherle
    . 1997. Effects of self-etching primer on enamel shear bond strengths and SEM morphology.American Journal of Dentistry10
    3
    :141146.
  • 40
    Hannig, M.
    ,
    H.Bock
    ,
    B.Bott
    , and
    W.Hoth-Hannig
    . 2002. Inter-crystallite nanoretention of self-etching adhesives at enamel imaged by TEM.European Journal of Oral Science110
    6
    :464470.
  • 41
    Abdalla, A. I.
    ,
    H. Y.El Sayed
    , and
    F.García-Godoy
    . 2008. Effect of hydrostatic pulpal water pressure on microtensile bond strength of self-etch adhesives to dentin.American Journal of Dentistry21
    5
    :327330.
  • 42
    Yoshida, Y.
    ,
    K.Nagakane
    ,
    R.Fukuda
    ,
    Y.Nakayama
    ,
    M.Okazaki
    ,
    H.Shintani
    ,
    S.Inoue
    ,
    Y.Tagawa
    ,
    K.Suzuki
    ,
    J.De Munck
    , and
    B.Van Meerbeek
    . 2004. Comparative study on adhesive performance of functional monomers.Journal of Dental Research83
    6
    :454458.
  • 43
    Fukegawa, D.
    ,
    S.Hayakawa
    ,
    Y.Yoshida
    ,
    K.Suzuki
    ,
    A.Osaka
    , and
    B.Van Meerbeek
    . 2006. Chemical interaction of phosphoric acid ester with hydroxyapatite.Journal of Dental Research85
    10
    :941944.
  • 44
    Can Say, E.
    ,
    M.Nakajima
    ,
    P.Senawongse
    ,
    M.Soyman
    ,
    F.Ozer
    ,
    M.Ogata
    , and
    J.Tagami
    . 2006. Microtensile bond strength of a filled vs unfilled adhesive to dentin using self-etch and total-etch technique.Dental Materials34
    4
    :283291.
  • 45
    Van Landuyt, K. L.
    ,
    Y.Yoshida
    ,
    I.Hirata
    ,
    J.Snauwaert
    ,
    J.De Munck
    ,
    M.Okazaki
    ,
    K.Suzuki
    ,
    P.Lambrechts
    , and
    B.Van Meerbeek
    . 2008. Influence of the chemical structure of functional monomers on their adhesive performance.Journal of Dental Research87
    8
    :757761.
  • 46
    Nagakane, K.
    ,
    Y.Yoshida
    ,
    I.Hirata
    ,
    R.Fukuda
    ,
    Y.Nakayama
    ,
    K.Shirai
    ,
    T.Ogawa
    ,
    K.Suzuki
    ,
    B.Van Meerbeek
    , and
    M.Okazaki
    . 2006. Analysis of chemical interaction of 4-MET with hydroxyapatite using XPS.Dental Materials Journal25
    4
    :645649.
  • 47
    Frankenberger, R.
    and
    F. R.Tay
    . 2005. Self-etch vs etch-and-rinse adhesives: Effect of thermo-mechanical fatigue loading on marginal quality of bonded resin composite restorations.Dental Materials21
    5
    :397412.
Copyright: Copyright: © 2009 This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL. 2009
Figure 1a and Figure 1b
Figure 1a and Figure 1b

The morphological interface between the total-etch adhesive Admira Bond and enamel. (The enamel was completely removed by dissolving in 0.1 N HCl for two hours to show the resin penetration into enamel). Two types of resin penetration are evident: infiltration into and between interprismitic (IP) substances that are of different thicknesses and morphology. In addition, interaprismitic infiltration can be seen (IAP) (Figure 1b).


Figure 2a and Figure 2b
Figure 2a and Figure 2b

The interface between Futurabond DC and enamel. The interprismitic diffusion (IP) was rather shallow and even absent in some locations. However, the intraprismitic diffusion (IAP) was evident in high magnification (Figure 2b). Many areas of nanometer resin diffusion were seen on the top surface of the prism.


Figure 3
Figure 3

Fracture surface of Admira Bond specimens after two years of water storage. Resins were still present in the interprismitic substances as well as the top prism itself.


Figure 4
Figure 4

Fracture surface of Hybrid Bond after two years of water storage. Resins were lost and interprismitic spaces are visible. Also, resins were lost from the prism itself.


Contributor Notes

Ali I Abdalla, PhD, DDS, professor, Department of Restorative Dentistry Faculty of Dentistry, University of Tanta, Tanta, Egypt

Albert J Feilzer, PhD, DDS, professor and chairman, Department of Dental Materials Science (ACTA), University of Amsterdam and Vrije University, Amsterdam, The Netherlands

*Reprint request: University of Tanta, Tanta, Egypt; e-mail: ali_abdalla79@yahoo.com
Received: 19 Jan 2009
  • Download PDF