In Vitro Marginal Fit of Three All-Ceramic Crown Systems Before and After Cementation

,
,
,
,
, and
Page Range: 641 – 649
DOI: 10.2341/11-012-L
Save
Download PDF

SUMMARY

Statement of the Problem

Full-coverage all-ceramic restorations are widely used. The impact of various classifications of luting agent on marginal discrepancies is not well understood.

Purpose

The purpose of this study was to evaluate the cervical fit of all ceramic crowns (IPS e.maxPress, Cergogold, and In Ceram) on bovine teeth with two luting agents before and after cementation.

Materials and Methods

Ninety bovine incisors were embedded in resin. The coronal portions of the teeth were prepared to receive full-coverage crowns. Thirty crowns of 7.0 ± 0.5 mm height, 8.0 mm cervical diameter, and 4.2 mm incisal diameter were fabricated for each ceramic system. The crowns were seated on the teeth, and the marginal discrepancy was measured using a measuring microscope. Then, 15 crowns of each ceramic system were luted on the teeth with resin cement (Variolink II) or resin-modified glass ionomer cement (Rely X luting), and the marginal discrepancy was measured. The results were submitted to analysis of variance, t test and Tukey's test (p<0.05).

Results

The three ceramic systems showed cervical fits after cementation statistically inferior to cervical fits before cementation for the two cements. The IPS e.maxPress showed values for cervical fit statistically superior to Cergogold before cementation. No statistically significant difference was found between IPS e.maxPress and In Ceram and In Ceram and Cergogold. After cementation, no statistically significant difference was found for the three ceramics systems when luted with resin or resin-modified glass ionomer luting agents.

Conclusions

Within the limitations of this study, it can be concluded that both cements studied increase the marginal discrepancy between the crown and the preparation for the three ceramic systems evaluated.

INTRODUCTION

Dental ceramics have increasingly become the best choice for achieving natural looking restorations and are appropriate materials to mimic destroyed or missing dental structures.1,2 These materials have desirable characteristics such as chemical stability, biocompatibility, high compressive strength, and a coefficient of thermal expansion similar to that of tooth structure.35 Moreover, recent progress in material technology and processing of ceramic restorations has expanded their indication for use due to more reliable results.6 Because of the fact that ceramics are indirect restorations and have to be cemented, there will be always be a space between the restoration and preparation. If this space is large, more luting material is exposed to the oral environment. Bacterial plaque can accumulate in this area and can result in gingival inflammation, caries, and pulp lesions, resulting in restoration failure.7,8 In addition, a large gap can create stress concentrations, which could reduce the final strength of the restoration.9

Different types of cement have been used, and there have been controversial opinions about which kind would be more appropriate.6,7 When considering all-ceramic restorations, it has been reported that fracture strength can be improved by using resin cement. It has been argued that this kind of cement should be the preference when cementing all-ceramic restorations.10,11 The development of resin-modified glass ionomer cement was intended to improve some physical properties that were present in the conventional glass ionomer cements with better esthetics, working time, and adhesion.12,13 Furthermore, it has been shown that resin-modified glass ionomer cement does not decrease the final strength of all ceramic crowns.14

Marginal discrepancies have been evaluated extensively; however, relatively small sample sizes and low numbers of measurements per specimen have limited statistical analysis.15 As few as four measurements per specimen have been reported, even though Groten et al16 stated that at least 50 measurements are required to achieve relevant information. A variety of methodologies have reported marginal discrepancies between 19 and 160 μm.1424 It has also been shown that discrepancies between the master die and inner surface of a crown will increase the gap. Steel dies or resin dies have been employed to measure the marginal accuracy of indirect restorations.2527 Although the use of these materials results in more accurate standardization of the abutment preparation, they do not supply the specific character of dental hard tissues.2832 In the present study, bovine teeth were used because they are histologically and morphologically similar to human dentin and are easier to obtain.33

The difference in marginal gap created using resin cement and resin-modified glass ionomer cement with different ceramic systems has not been thoroughly reported. The aim of this study was to evaluate the cervical fit of all-ceramic crowns (IPS e.maxPress, Cergogold, and In Ceram) on bovine teeth with two cements before and after cementation. The null hypotheses were 1) the type of cement does not affect the marginal adaptation of the three different ceramic systems and 2) there is no difference before and after cementation with respect to the marginal adaptation of the three different ceramic systems.

METHODS AND MATERIALS

All materials studied are listed in Table 1.

Table 1:  Materials Used in the Studya
Table 1: 

Ninety bovine mandibular incisors were collected and stored in a 10% formalin solution.16 Calculus deposits and soft tissue were removed from the selected teeth with a scaler and cleaned with a bristle brush and nonfluoridated flour of pumice (Zircate Prophy Paste, Dentsply, Milford, DE). Mechanical retention was made in the root of the tooth before embedding with autopolymerizing acrylic resin (Jet, Clássico-Produtos Odontológicos, São Paulo, Brazil) in polyvinyl chloride tubes (Marron, Tigre, Joinvile, Brazil). The teeth were placed upright with the long axes parallel to the height of the tube, and the cemento-enamel junctions (CEJ) were placed 3 mm above the resin. The assembled specimens were attached to a lathe (Nardini-ND 250 BE, São Paulo, Brazil) with a grinding device and preparation accomplished under water spray. The final dimensions of the preparations were 7.0 ± 0.5 mm in height, 8.0 mm for the cervical diameter, and 4.2 mm for the incisal diameter, which resulted in a peripheral surface convergence of 8°. This degree of convergence was used since it has been shown that retention increases considerably as the taper decreases.24 A 0.8-mm-deep shoulder finish line with a rounded internal line angle was prepared using a diamond instrument (No. 5850-018; Brasseler USA, Savannah, GA). All sharp angles were rounded, and all cervical margins were located 1.0 ± 0.2 mm above the CEJ (Figure 1). All teeth were measured after the preparation using a precision electronic micrometer (Electronic Micrometer; LS Starrett, Athol, MA) with an accuracy of 0.002 mm.16

Figure 1. . Schematic diagram of full-coverage preparation.Figure 1. . Schematic diagram of full-coverage preparation.Figure 1. . Schematic diagram of full-coverage preparation.
Figure 1.  Schematic diagram of full-coverage preparation.

Citation: Operative Dentistry 37, 6; 10.2341/11-012-L

The 90 prepared teeth were divided into three groups (n=30) as follows: In Ceram Alumina, IPS e.maxPress, and Cergogold. An impression was made for each prepared tooth with a polyvinyl siloxane impression material (Express, 3M ESPE, St Paul, MN) using a custom-made impression tray fabricated with acrylic resin. Then, type IV gypsum (Fuji Rock, GC America, Aslip, IL) was poured to produce dies. The teeth were stored in distilled water at 37°C until the cementation process.

The dies were coated with one layer of die spacer (Spacelaquer Ducera Lay, Degussa Huls, Hanau, Germany) to approximately 1 mm above the finish line. For IPS e.maxPress and Cergogold, the dies were isolated with lubricating oil (Die Lube, Dentaurum J.P. Winkelstroeter KG, Pforzheim, Germany) and 0.7-mm-thick wax patterns were prepared over the master dies using a wax-dipping unit (Hotty, Renfert, Hilzingen, Germany). Following the preparation of the wax patterns, each pattern was sprued and invested in an investing ring. A two-stage burnout sequence was used: temperature increased 5°C/minute to 250°C and held for 30 minutes before increasing the temperature at 5°C/minute to 850°C and holding for 1 hour. After the preheating stage, the investment cylinders were immediately transferred to the pressing furnace (EP500, Ivoclar AG, Schaan, Liechtenstein). The pressing temperatures for Empress 2 core and Cergogold core ceramics were 920°C and 850°C, respectively. Following the pressing procedure, the investment cylinders were removed from the pressing furnace and cooled for 2 hours in a ventilated room. The cooled specimens were divested by grit blasting with 80-μm glass beads (Williams glass beads, Ivoclar North America, Amherst, NY). Before etching, the sprues were cut away, and excess sprue segments were removed by grinding from the specimen surfaces using water as a coolant. The core specimens were placed in one plastic bottle containing 20 mL of 1% hydrofluoric acid solution (Invex Liquid, Ivoclar AG), and these bottles were placed in an ultrasonic bath. After etching, the specimens were cleaned under running tap water for 10 seconds and then dried thoroughly. These procedures were performed by a certified dental technician.

For the In Ceram alumina, three layers of die spacer (Vita Zanfabrik, Seefeld, Germany) were applied on the stone die surface to approximately 1 mm above the finish line. Impressions were made using a polyvinyl siloxane impression material (Express, 3M ESPE) with a plastic ring. These impressions were poured with In Ceram special plaster using a liquid-to-powder ratio of 0.23 mL/g to make refractory models. In Ceram powder slip was prepared according to the manufacturer's instructions and was applied to the models. A sculpturing device was used to ensure a uniform core thickness.19 The stabilizer was applied, and the coping was fired on the plaster dies and infiltrated with glass. Excess glass was removed with a diamond bur. These procedures were conducted in an authorized laboratory by a certified technician. The final dimension of IPS e.maxPress and Cergogold copings were 0.7 mm and 0.5 mm for In Ceram.

The veneer porcelains (e.max Ceram , Ivoclar for IPS e.maxPress core; VM7, Vita Zahnfabrik for In Ceram core and Duceragold, Degussa Dental for Cergogold core) were applied to the core materials, which had been placed in a split brass mold to make a complete crown shape with a stratification porcelain thickness measuring 0.1 mm for IPS e.maxPress and Cergogold and 0.3 mm for In Ceram specimens in the cervical region and increasing in thickness in accordance with the taper angle. Following veneer porcelain sintering, the final dimensions of the crowns were 0.8 mm in the cervical region, 1.0 mm in the mid-facial region, and 1.5 mm in the incisal region.16

Measurements of Marginal Adaptation Before Cementation

Tooth surfaces were cleaned with a bristle brush and nonfluoridated flour of pumice (Zircate Prophy, Dentsply). Each crown was placed onto its preparation under a constant controlled pressure of 9 kgf for 1 minute using a pneumatic pressure machine (developed in the Dental Materials Laboratory of the University of Campinas School of Dentistry, Piracicaba, Brazil). A metallic device was designed to maintain the assembled tooth/restoration at a reproducible position and allow measurement on a measuring optical microscope (Nikon measurescope UM2, Nikon Co, Tokyo, Japan) at original magnification 50×. The accuracy of the microscope was ±0.5 μm. The marginal discrepancy was evaluated by measuring the gap between the edge of the crown and prepared tooth margin. Sixteen diametrically placed marks were created on the root tooth surface 2 mm below the prepared margin using a round diamond bur (#1011, KGSorensen, São Paulo, Brazil). The distance of the gap was measured at each demarcated area with four different measurements. These measurements were taken from the prepared margin to the edge of the crown (Figures 2 and 3).

Figure 2. . Points of measurement and view of the assembled specimen.Figure 2. . Points of measurement and view of the assembled specimen.Figure 2. . Points of measurement and view of the assembled specimen.
Figure 2.  Points of measurement and view of the assembled specimen.

Citation: Operative Dentistry 37, 6; 10.2341/11-012-L

Figure 3. . Assembled specimen under the microscope.Figure 3. . Assembled specimen under the microscope.Figure 3. . Assembled specimen under the microscope.
Figure 3.  Assembled specimen under the microscope.

Citation: Operative Dentistry 37, 6; 10.2341/11-012-L

Application of Cement

Variolink II (Ivoclar-Vivadent, Schaan, Liechtenstein)

Tooth surfaces were cleaned with a bristle brush and nonfluoridated flour of pumice (Zircate Prophy, Dentsply). The dentin was treated for 15 seconds with 35% phosphoric acid and rinsed for 10 seconds under running tap water. Excess water was removed with a cotton pellet, leaving a moist surface. Two consecutive coats of adhesive were then applied using a saturated microbrush tip. The ceramic surface was etched with 10% hydrofluoric acid (Ácido hidrofluorídrico, Dentsply Brazil, Petropolis, RJ, Brazil) for 1 minute (Cergogold and In Ceram) or for 20 seconds (IPS e.maxPress), followed by rinsing for 1 minute. Samples were then ultrasonically cleaned with distilled water for 10 minutes and dried with oil-free air. The silane agent Monobond S (Ivoclar-Vivadent) was applied, and the surface was dried after 1 minute using compressed air. The resin cement was mixed and applied to the internal ceramic crown surface. A load of 454 gf was applied while the excess cement was removed. The cement was light-cured (XL3000, 3MEspe) for 40 seconds on each side (labial, lingual, medial, and distal) of the crown, resulting in 160 seconds of light polymerization for each crown with 500 mW/cm2 light intensity. Ten minutes after the start of the mix, specimens were immersed in distilled water at 37°C and stored until testing.

Rely X luting (3M ESPE)

The procedures were the same as for the aforementioned resin cement, but the dentin was simply cleaned and did not receive any adhesive application. The specimens were stored in distilled water for 24 hours before making the measurements.

Measurements of Marginal Adaptation After Cementation

The marginal discrepancy was measured as described for marginal adaptation measurment before cementation (Figures 2 and 3). However, the pressure was not applied because the crowns were already cemented. ANOVA one-way, post hoc Tukey and t test were applied (Table 2). The marginal adaptations were determined, and since two different cements were used and the readings were before and after cementation, the data were statistically analyzed using two-way analysis of variance (ANOVA), with the independent variables being the cement and the time of evaluation (before and after cementation) (Tables 3, 4 and 5). Means and standard deviations were calculated for each material and each condition. Individual comparisons between the materials and conditions were made using a Tukey Honestly Significant Difference test to determine significant differences. All statistical testing was performed with α=0.05.

Table 2:  Statistical Analysisa
Table 2: 
Table 3:  Marginal Discrepancies of the Three Ceramic Systems Before and After Cementation With Resin-Modified Glass Ionomer Cement (Means and Standard Deviations [SD] in μma
Table 3: 
Table 4:  Marginal Discrepancies of the Three Ceramic Systems Before and After Cementation With Resin Cement (Means and Standard Deviations [SD] in μm)a
Table 4: 
Table 5:  Marginal Discrepancies of the Three Ceramic Systems After Cementation With Resin Cement and Resin-Modified Glass Ionomer Cement (Means and Standard Deviations [SD] in μm)a
Table 5: 

RESULTS

The one-way ANOVA (Table 2) revealed significant differences in the marginal discrepancy values (p<0.001). Tables 3, 4, and 5 show the mean marginal discrepancies and standard deviations. Table 3 displays the values of the three ceramic systems before and after cementation with resin-modified glass ionomer cement. It can be seen that before cementation, IPS e.maxPress resulted in a discrepancy significantly higher than Cergogold, and both did not differ from In Ceram (p<0.05). The same situation was observed after cementation (p<0.05). When comparing the discrepancies within each ceramic before and after cementation, the results after cementation were statistically significantly higher than before cementation (p<0.05).

Table 4 shows the mean values of discrepancies of the three ceramic systems before and after cementation with resin cement. It can be observed that before cementation, IPS e.maxPress resulted in a discrepancy significantly higher then Cergogold, and both IPS e.maxPress and Cergogold did not differ from In Ceram (p<0.05). The same situation was observed after cementation (p<0.05). When comparing the discrepancies within each ceramic before and after cementation, the results after cementation showed a statistically significant increase (p<0.05). Table 5 compares the mean values of discrepancies between the two cements for the three ceramic systems. It shows that there was no statistically significant difference between the cements for the ceramics evaluated.

DISCUSSION

The null hypotheses that the type of cement does not affect the marginal adaptation of the three different ceramic systems and that the time of evaluation (before and after cementation) does not affect the marginal adaptation of the three different ceramic systems were rejected by the results. The marginal discrepancy of the three ceramic systems evaluated was affected by the cement and by the time of evaluation (Tables 3 and 4). These results seem to correlate well with in vitro studies assessing the discrepancies of ceramic restorations.19,20 Many studies evaluating the marginal discrepancy of all-ceramic crowns have been published;15,17,1921 however, no study was found comparing resin-modified glass ionomer cement and resin cement before and after cementation for different ceramic restoration systems. It is well known that resin cement is the most popular luting agent when using all-ceramic restorations34; however, resin-modified glass ionomer cement has been used to cement all-ceramic restorations, and some authors argue that this cement has advantages.13,14 Even though controversy exists regarding a clinically acceptable marginal adaptation, the study by McLean and von Fraunhofer18 proposed that a restoration would be successful if marginal gaps of less than 120 μm could be obtained. Before cementation, the marginal discrepancy of the all-ceramic systems evaluated in the current study was within this clinically acceptable standard, and it is in agreement with other studies1921 that found marginal discrepancies deemed clinically acceptable. Nevertheless, the current results do not agree with Grey et al26 that found discrepancies larger than 120 μm for conventional In Ceram crowns. After cementation, Cergogold and In Ceram showed acceptable discrepancy values for both cements evaluated, but IPS e.maxPress resulted in a discrepancy larger than recommended (Tables 3, 4, and 5). Some studies have evaluated the marginal discrepancies without taking the cementation process into consideration.3537 Evaluating discrepancies without luting them is not reflective of clinical reality because the cement and the cementation process play a relevant role in the final discrepancy achieved. In the current study, although a space was created to allow the cement to flow into the space between the tooth and internal ceramic surface, the results for the all-ceramic and cement combinations increased the discrepancy after cementation. The convergence angle could influence the final marginal discrepancy acquired since an angle with a higher divergence would permit easier displacement of the cement. In the current study, the 8° taper angle might not have allowed the same flow of the cements as a clinical preparation would, because clinical angles range between 12° and 20°, and increased taper could affect the crown retention.23,24 However, the current results are in agreement with previous studies that found an increase in the marginal discrepancy after cementation using approximately the same tapering.19,20 Further study should be pursued to delineate the optimum convergence angle for adhesively retained all-ceramic restorations. Despite the fact that ceramic restorations have been used extensively, the cementation procedure is one of the most critical parts of the overall process. In the present study, the conditions were well controlled. Even though clinically, the practitioner cares about the final fit of the restoration, it is not possible to control all of the steps as in an experimental study. Since an increase in marginal discrepancy was seen in a well-controlled environment, it would seem important for the clinician to pay close attention to environmental factors that might interfere with the cement line thickness.

CONCLUSION

Within the limitations of this study, it can be concluded that the cementation increases the marginal gap between the crown and the preparation for the three ceramic systems evaluated regardless of the type of cement evaluated.

Acknowledgments

This investigation was supported by the University of Uberaba, Brazil. The authors thank Jeffrey A. Platt for aid in manuscript preparation.

Conflict of Interest

The authors of this article certify that they have no proprietary, financial, or other personal interest of any nature or kind in any product, service, and/or company that is presented in this article.

REFERENCES

  • 1.
    Heydecke G,
    Thomason JM,
    Lund JP,
    &
    FeineJS
    (2005) The impact of conventional and implant supported prostheses on social and sexual activities in edentulous adults: results from a randomized trial 2 months after treatmentJournal of Dentistry33(
    8
    ) 649-657.
  • 2.
    Raptis NV,
    Michalakis KX,
    &
    HirayamaH
    (2006) Optical behavior of current ceramic systemsInternational Journal of Periodontics and Restorative Dentistry26(
    1
    ) 31-41.
  • 3.
    Mitchell CA,
    &
    OrrJF
    (2005) Engineering properties and performance of dental crownsProceedings of the Institution of Mechanical Engineers219(
    4
    ) 245-255.
  • 4.
    Chu S,
    &
    AhmadI
    (2005) A historical perspective of synthetic ceramic and traditional feldspathic porcelainPractical Procedures and Aesthetic Dentistry17(
    9
    ) 593-598.
  • 5.
    Xible AA,
    de Jesus Tavarez RR,
    de Araujo Cdos R,
    &
    BonachelaWC
    (2006) Effect of silica coating and silanization on flexural and composite-resin bond strengths of zirconia posts: an in vitro studyJournal of Prosthetic Dentistry95(
    3
    ) 224-229.
  • 6.
    Fradeani M,
    D'Amelio M,
    Redemagni M,
    &
    CorradoM
    (2005) Five-year follow-up with Procera all-ceramic crownsQuintessence International36(
    2
    ) 105-113.
  • 7.
    Santos GC Jr,
    Santos MJ,
    &
    RizkallaAS
    (2009) Adhesive cementation of etchable ceramic esthetic restorationsJournal of Canadian Dental Association75(
    5
    ) 379-384.
  • 8.
    Orstavik D,
    &
    OrstavikJ
    (1976) In vitro attachment of Streptococcus sanguis to dental crown and bridge cementsJournal of Oral Rehabilitation3(
    2
    ) 139-144.
  • 9.
    Tuntiprawon M,
    &
    WilsonPR
    (1995) The effect of cement thickness on the fracture strength of all-ceramic crownsAustralian Dentistry Journal40(
    1
    ) 17-21.
  • 10.
    Kelly JR,
    Giordano R,
    Pober R,
    &
    CimaMJ
    (1990) Fracture surface analysis of dental ceramics: clinically failed restorationsInternational Journal of Prosthodontics3(
    5
    ) 430-440.
  • 11.
    Groten M,
    &
    ProbsterL
    (1997) The influence of different cementation modes on the fracture resistance of feldspathic ceramic crownsInternational Journal of Prosthodontics10(
    2
    ) 169-177.
  • 12.
    Kim Y,
    Hirano S,
    &
    HirasawaT
    Physical properties of resin-modified glass-ionomers Dental Materials Journal 17(
    1
    ) 68-76.
  • 13.
    Chan WD,
    Yang L,
    Wan W,
    &
    RizkallaAS
    (2006) Fluoride release from dental cements and composites: a mechanistic studyDental Materials22(
    4
    ) 366-373.
  • 14.
    Leevailoj C,
    Platt JA,
    Cochran MA,
    &
    MooreBK
    (1998) In vitro study of fracture incidence and compressive fracture load of all-ceramic crowns cemented with resin-modified glass ionomer and other luting agentsJournal of Prosthetic Dentistry80(
    6
    ) 699-707.
  • 15.
    Yeo IS,
    Yang JH,
    &
    LeeJB
    (2003) In vitro marginal fit of three all-ceramic crown systemsJournal of Prosthetic Dentistry90(
    5
    ) 459-464.
  • 16.
    Groten M,
    Axmann D,
    Probster L,
    &
    WeberH
    (2000) Determination of the minimum number of marginal gap measurements required for practical in-vitro testingJournal of Prosthetic Dentistry83(
    1
    ) 40-49.
  • 17.
    Kern M,
    Schaller HG,
    &
    StrubJR
    (1993) Marginal fit of restorations before and after cementationin vivo International Journal of Prosthodontics6(
    6
    ) 585-591.
  • 18.
    McLean JW,
    &
    von FraunhoferJA
    (1971) The estimation of cement film thickness by an in vivo techniqueBrazilian Dentistry Journal131(
    3
    ) 107-111.
  • 19.
    Beschnidt SM,
    &
    StrubJR
    (1999) Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouthJournal of Oral Rehabilitation26(
    7
    ) 582-593.
  • 20.
    Groten M,
    Girthofer S,
    &
    ProbsterL
    (1997) Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitroJournal of Oral Rehabilitation24(
    12
    ) 871-881.
  • 21.
    Balkaya MC,
    Cinar A,
    &
    PamukS
    (2005) Influence of firing cycles on the margin distortion of 3 all-ceramic crown systemsJournal of Prosthetic Dentistry93(
    4
    ) 346-355.
  • 22.
    Leempoel PJB,
    Lemmens PL,
    Snoek PA,
    &
    van't HofMA
    (1987) The convergence angle of tooth preparations for complete crownsJournal of Prosthetic Dentistry58(
    4
    ) 414-416.
  • 23.
    Nordlander J,
    Weir D,
    Stoffer W,
    &
    OchiS
    (1988) The taper of clinical preparations for fixed prosthodonticsJournal of Prosthetic Dentistry60(
    2
    ) 148-151.
  • 24.
    Jorgensen KD
    (1955) The relationship between retention and convergence angle in cemented veneer crownsActa Odontologica Scandinavica13(
    1
    ) 35-40.
  • 25.
    Bottino MA,
    &
    ValandroLF
    (2007) The influence of cervical finish line, internal relief, and cement type on the cervical adaptation of metal crownsQuintessence International38(
    7
    ) 425-432.
  • 26.
    Grey NJ,
    Piddock V,
    &
    WilsonMA
    (1993) In vitro comparison of conventional crowns and a new all-ceramic systemJournal of Dentistry21(
    1
    ) 47-51.
  • 27.
    Lee KB,
    Park CW,
    Kim KH,
    &
    KwonTY
    (2008) Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systemsDental Materials Journal27(
    3
    ) 422-426.
  • 28.
    Limkangwalmongkol P,
    Kee E,
    Chiche GJ,
    &
    BlatzMB
    (2009) Comparison of marginal fit between all-porcelain margin versus alumina-supported margin on Procera Alumina crownsJournal of Prosthodontics18(
    2
    ) 162-166.
  • 29.
    Comlekoglu M,
    Dundar M,
    Ozcan M,
    Gungor M,
    Gokce B,
    &
    ArtuncC
    (2009) Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crownsOperative Dentistry34(
    5
    ) 586-592.
  • 30.
    Krifka S,
    Anthofer T,
    Fritzsch M,
    Hiller KA,
    Schmalz G,
    &
    FederlinM
    (2009) Ceramic inlays and partial ceramic crowns: influence of remaining cusp wall thickness on the marginal integrity and enamel crack formation in vitroOperative Dentistry34(
    1
    ) 32-42.
  • 31.
    Federlin M,
    Krifka S,
    Herpich M,
    Hiller KA,
    &
    SchmalzG
    (2007) Partial ceramic crowns: influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrityin vitro Operative Dentistry32(
    3
    ) 251-260.
  • 32.
    Federlin M,
    Schmidt S,
    Hiller KA,
    Thonemann B,
    &
    SchmalzG
    (2004) Partial ceramic crowns: influence of preparation design and luting material on internal adaptationOperative Dentistry29(
    5
    ) 560-570.
  • 33.
    Nakamichi I,
    Iwaku M,
    &
    FusayamaT
    (1983) Bovine teeth as possible substitutes in the adhesion testJournal of Dentistry Research62(
    10
    ) 1076-1081.
  • 34.
    Hill EE
    (2007) Dental cements for definitive luting: a review and practical clinical considerationsDental Clinic of North America51(
    3
    ) 643-658.
  • 35.
    Holden JE,
    Goldstein GR,
    Hittelman EL,
    &
    ClarkEA
    (2009) Comparison of the marginal fit of pressable ceramic to metal ceramic restorationsJournal of Prosthodontics18(
    8
    ) 645-648.
  • 36.
    Al-Rabab'ah MA,
    Macfarlane TV,
    &
    McCordJF
    (2008) Vertical marginal and internal adaptation of all-ceramic copings made by CAD/CAM technologyEuropean Journal of Prosthodontics Restorative Dentistry16(
    3
    ) 109-115.
  • 37.
    Kokubo Y,
    Tsumita M,
    Kano T,
    Sakurai S,
    &
    FukushimaS
    (2011) Clinical marginal and internal gaps of zirconia all-ceramic crownsJournal of Prosthodontic Research55(
    1
    ):40-43.
Copyright: Operative Dentistry, Inc. 2012
Figure 1. 
Figure 1. 

Schematic diagram of full-coverage preparation.


Figure 2. 
Figure 2. 

Points of measurement and view of the assembled specimen.


Figure 3. 
Figure 3. 

Assembled specimen under the microscope.


Contributor Notes

Corresponding author: University of Uberaba, Dental Materials and Restorative Dentistry, Nene Sabino Avenue, 1801, Uberaba, Minas Gerais 38055500, Brazil; e-mail: gilberto.borges@uniube.br
Accepted: 13 Jan 2012
  • Download PDF