Editorial Type:
Article Category: Literature Review
 | 
Online Publication Date: 01 Sept 2013

In Vitro Performance of Class I and II Composite Restorations: A Literature review on Nondestructive Laboratory Trials—Part II

,
,
, and
Page Range: E182 – E200
DOI: 10.2341/12-020B-LIT
Save
Download PDF

ABSTRACT

A literature review was conducted on adhesive Class I and II restorations and nondestructive in vitro tests using the PubMed/Medline database for the 1995-2010 period. The first part of this review has presented and critically appraised selected literature dealing with the quality and in vitro behavior of adhesive Class II restorations using photoelasticity, finite element analysis, and microleakage study protocols. This second part reviews additional parameters, which are deformation and fracture resistance to cyclic loading, shrinkage stress and tooth deformation following restoration placement, bond strength (microtensile, tensile, and shear tests), and marginal and internal adaptation. In addition, a “relevance score” has been proposed that aims to classify the different study protocols according, firstly, to the resulting quality, quantity, and consistency of the evidence and then, secondly, to their potential clinical relevance, as estimated by their ability to simulate oral and biomechanical strains. The highest clinical relevance was attributed to marginal and internal adaptation studies, following cyclic loading in a moist environement. However, a combination of in vitro protocols will have an even greater predictive potential and has to be considered as a crucial preclinical research approach with which to investigate the numerous restorative configurations that cannot be efficiently and rapidly tested in vivo.

INTRODUCTION

Posterior adhesive restorations, as a substitute for metal-based restorations, have become the “standard of care” in an increasing number of dental offices and clinics.1-3 However, the abundant number of available restorative options implies a limited standardization of these techniques, and this may lead to the possible application of improper clinical protocols. The time and effort demanded by in vivo trials does not permit all adhesive systems, base liners, and restorative products/techniques to be evaluated in prospective clinical studies and over a sufficient period of time. Therefore, the need for and the advantages of preclinical in vitro trials is undeniable. Unfortunately, the many laboratory evaluation protocols and their variability and complexity, coupled with an already-intricate study field, means that there is a clear need to organize in vitro research on Class II adhesive restorations. Furthermore, this organization should be based on the ability of the research protocol to reproduce the most important oral strains, to evaluate and tentatively appraise the potential clinical relevance, and to follow a thinking process successfully applied in clinical biomedical science.4-12

Part one of this review selected literature dealing with the quality and in vitro behavior of adhesive Class II restorations using photoelasticity, finite element analysis (FEM), and microleakage study protocols. Photoelasticity demonstrated that higher stresses could be observed in large cavities and those restored using a light-curing material compared to a chemically curing one.13-15 However, photoelasticity did show atypical results when comparing layering and bulk-filling techniques.16,17 Unfortunately, this method carries several conceptual and methodological limitations and therefore is characterized by improper quality and consistency of the evidence. It has been advantageously replaced by FEM.

The crucial role of the FEM protocol was validated by comparing stress levels in similar restorative configurations using natural teeth and strain gauges.18,19 This method then confirmed the influence of cavity design and dimensions,20-23 layering techniques,24,25 and the physical characteristics of the materials, such as stiffness,26-33 with a good consistency of the evidence. Despite the fact that FEM neither emulates the effect of moisture nor that of cyclic masticatory function (fatigue), the recent three-dimensional modeling approach shows a good quality of the evidence for stress distribution within the tooth-restoration as a whole.

The use of the microleakage protocol only allowed a few hypotheses to be confirmed with a good consistency of results. Only cavity and margin design,34,35 light-curing type,36,37 and composite structure and technology38-41 had an influence on microleakage. However, there are a lot of studies utilizing this protocol, possibly because of its simplicity. When more of these studies were reviewed, the conclusions proved highly inconsistent. This strongly indicates that further use of the microleakage protocol should be limited as a result of the overall poor quality and consistency of the evidence associated with this protocol.

The second part of this review will cover the remaining nondestructive in vitro protocols, which are 1) deformation resistance and fracture resistance to cyclic loading, 2) shrinkage stress and related tooth deformation, 3) bond strength (microtensile, tensile, and shear tests), and 4) marginal and internal adaptation. In addition, a “relevance score” will be proposed based on the aforementioned criteria (quality, quantity, and consistency of the evidence), taking into consideration the ability of the protocol to simulate oral biomechanical strains.

MATERIALS AND METHODS

The search strategy, detailed in Part I of this review, included an appraisal of the PubMed/Medline database using the following primary key words: in vitro, Class II, posterior composites, inlays and onlays, tooth colored, and composite. For this second part, additional key words related to study hypothesis, such as cavity configuration, polymerization, or light-curing, or to study methodology, such as resistance to fracture and deformation, shrinkage stress, tooth deformation, bond strength and microtensile bond strength, and marginal and internal adaptation, were used to identify all existing references. The search was conducted with the limit “Dental Journal” and from 1995 to 2010. Perusal of the references of relevant articles allowed completion of the review (references of the references). A few older “major” references were cited, when appropriate. Articles were first classified according to the experimental protocol, each one corresponding to a specific review table, and were then subclassified according to the parameters/hypothesis investigated. For microleakage, bond strength, and marginal adaptation protocol, the type of restoration (direct and indirect) was also considered, and then the references were analyzed according to the subparameters previously described in part one of this review). The overall strength of evidence was appraised according to the three factors of quality, quantity, and consistency. Whenever possible and appropriate, the approach applied was the same as introduced in 1994 by Gyorkos and Abrahamowicz.7 This process is now well established and largely used to develop practice guidelines and other health-related policy advice.8-12

References related exclusively to indirect ceramic and CAD-CAM/Cerec® restorations (Sirona, Bensheim, Germany) or restoration fit, as well as those dealing with restoration of deciduous teeth, were excluded from this review. In addition, wear tests and studies measuring restoration fracture resistance to monotonic stress/loading (in general, all kinds of destructive tests) were not taken into consideration for this literature review.

I. Deformation and Resistance to Cyclic Loading

The studies that were reviewed are presented in Table 1. When comparing the deformation of intact and restored teeth using composite or ceramic in MOD cavities, the mean tooth compliance (relative deformation) after preparation was about 2.0, and mean tooth compliance was back to 1.1 in composite and 1.0 in the ceramic group. This demonstrated the ability of both restorative materials to reinstall tooth resistance under a load of 11.17 Kg.42 However, after cyclic loading, more samples fractured in the composite group than in the ceramic group, although this was not significant in terms of mean cycles to failure.

Table 1: Selected references for deformation and resistance to cyclic loading
Table 1:

The resistance to fracture following cyclic loading and increasing force (200 to 1000 N) for composite MOD onlays (buccal cusp replacement) with or without additional palatal partial coverage demonstrated an increasing resistance to fracture with full occlusal coverage. However, at the same time, more dramatic failure patterns were observed.43 Therefore, clinical recommendations could not be drawn, as lowering the remaining cusp could eventually lead to untreatable failures. The aforementioned results were submitted to additional FEM analysis, and this substantiated the superior resistance to fracture of the overlay configuration and also provided a more detailed picture of the various stresses (tensile, shear, and compressive) that account for adhesive interface or restoration failure.21 It was also concluded that adhesive failures are more likely to occur with a high E-modulus composite and that lowering the E-modulus might trigger cohesive restoration fractures. Another study44 from the same authors included ceramic overlays, which were compared to direct and indirect composite restorations. In this study, no significant difference was observed with regard to overall fatigue resistance among the three restorative options, while a combination of adhesive and cohesive failures was predominantly observed in the indirect groups.44 These latter results might be attributed to a lower mechanical resistance of the adhesive interface and cement layer underneath indirect restorations and, in particular, to the lower stiffness of the cement, compared to a highly filled composite (82 vol% and 92 wt%) or ceramic restoration. The aforementioned studies thus concluded that in a vital tooth configuration, with cyclic loading ranging from normal function (200 N) to parafunctional forces (1000 N), the choice of material might not be a crucial factor for overall mechanical resistance and clinical success. However, it must pointed out that the tested composites (direct and indirect) were conventional, highly filled hybrids, with high E-modulus (19.6 GPa and 23.0 GPa), and these are markedly higher than the current nano-hybrid materials with moduli around 10 GPa or lower.

Magne and coworkers45-48 interestingly applied a similar protocol to a nonvital tooth configuration with forces ranging from 200 N to 1000 or 1400 N. In their first article, the influence of restoration thickness (1.5 to 3.5 mm) using a composite system developed for CAD-CAM technology (Paradigm MZ100®, 3M, St Paul, MN, USA) was tested. They observed that increasing the thickness of the restoration improved the resistance to fatigue and also reduced the occurrence of subgingival fractures. This demonstrated the protective effect of thick composite overlays made of high mechanical strength and E-modulus composite.46 When comparing 3-mm–thick ceramic (Vita MKII CEREC, VITA Zahnfabrik, Bad Säckingen, Germany) and composite (Paradigm MZ100) overlays, the fatigue resistance of the composite material was significantly superior, and the efficiency of immediate dentin sealing (to establish adhesion prior to impression) was also effective, as demonstrated by an absence of adhesive failures.49 The same protocol was repeated with a restorative nano-hybrid composite, and these composite overlays showed a better resistance to fatigue than did the ceramic restorations.48 When comparing both composites, Paradigm MZ100 exhibited a higher survival rate (73%) compared to the nano-hybrid brand (50%), even though this was not statistically significant. In the same test, none of the ceramic restorations survived the last test phase at 1400 N. Moreover, ceramic restorations showed a much higher proportion of subgingival, nonrepairable fractures.46,48,49 These two series of studies dealing with either a vital or nonvital tooth configuration evaluated the behavior of restorations under physiological and nonphysiological parafunctional forces. The protocol included a FEM to tentatively explain the findings with a natural substrate. In the vital tooth configuration, the choice of material appeared less influential than the restoration configuration with regard to fracture resistance and failure pattern. Conversely, in a nonvital tooth situation, the choice of material and the restoration thickness markedly influenced the stress distribution, fracture resistance, and fracture pattern.

Conclusion: Deformation and Resistance to Fatigue Loading

The aforementioned findings might have a crucial impact on our understanding of restoration reaction and resistance to cyclic forces. Specifically, the potential impact of the material's physical characteristics (ie, E-modulus and flexural strength) on medium- and long-term restoration behavior might largely depend on the extent of the preparation and the intrinsic capacity of the remaining tooth structure to resist functional stresses. In a vital tooth, it can be logically assumed that the restoration plays a less important protective role than it does in a nonvital configuration. In addition, a less rigid (significantly less than dentin; ie, nano-hybrid composite) or stiff and brittle material (ie, felspathic porcelain) would likely increase the risk of restoration/tooth failure when treating fragile teeth (nonvital) in high stress-bearing areas. The quality and consistency of the evidence here are satisfactory. However, the quantity of the evidence is rather limited, although such criteria seem less crucial as a result of the protocol applied (same tooth/teeth used for testing different cavity configurations or FEM stress simulation).

Only nondestructive tests or those involving cyclic loading were taken into consideration for this review because of the fact that mere resistance to fracture (“classical” fracture-resistance protocol) mimics the reaction of the system to extreme monotonic, linearly increasing stresses, and these are considered as poorly relevant as simulations for in vivo failures. Such tests neither reproduce accidental fracture (totally different stress kinetics) nor simulate other restoration failure patterns such as marginal leakage, tissue demineralization, pulpal complication, or fractures triggered by repeated stresses (fatigue). Likewise, the fracture patterns observed in such tests (which include axial or severe cusp and restoration fractures of vital tooth configurations) are practically nonexistent in vivo, with the exception of rather rare traumatic tooth fractures.50 One can therefore assume that the quality of evidence would be insufficient, and this justifies the exclusion of such research in the present review.

II. Deformation of Teeth and Shrinkage Stress During and After Restoration Placement

The studies that were reviewed are presented in Table 2.

Table 2: Selected references for deformation of teeth ands stress during and after restoration placement
Table 2:

Layering Techniques

When comparing different composite filling techniques (bulk, bulk + re-restoration and incremental) to amalgam restoration in Class II MOD cavities of different widths (1, 2.5, and 5 mm), more deformation resulted from adhesive techniques, with the highest deformation being measured in 5-mm bulk composite restorations.51 The concept of re-restoring a tooth involves the placement of a bulk-fill composite restoration that is fully polymerized, and then a new slot is subsequently cut into the composite after polymerization. This slot is subsequently restored with more composite, and this technique has been proposed as a means to dissipate stress in the final restored tooth. In this study, it was observed that re-restoration did reduce stress compared to initial values.

In Class I cavities, tooth deformation proved to be minimal in comparison to Class II MO (medium or large) or MOD cavities. The size and cavity design or configuration factor proved to be influential factors for tooth deformation52 and also for stress development. This occurred in an inverse relationship at the restorative interface, as measured directly on teeth and by FEM study.19 More recent studies have confirmed the increased deformation observed in Class II MOD restorations when compared to two-surface MO design53 as well as the reduction of tooth deformation that is observed with layering techniques.54 However, in this later study, no significant difference was observed between the horizontal and oblique layering techniques.

The deformation of intact and restored teeth using composite or ceramic in MOD cavities was also reviewed. The studies showed a mean tooth “compliance” of 2.0 (relative deformation) following preparation, and then the “compliance” reverted to 1.1 in the composite group and 1.0 in the ceramic group. This demonstrated the ability of both restorative materials to return the tooth's resistance to flexure under a load of 11.17 Kg.42

Curing Protocols

Versluis and coworkers19 studied the effect of the curing protocol by using various combinations of light intensity and exposure time (but corresponding to similar curing energy) and observed large variations in shrinkage strain, as measured by both FEM and experimental methods. Their results actually revealed the positive impact of extending curing time with a reduced light intensity.19 Various curing light units and polymerization protocols where compared with regard to cuspal deflection of MOD restorations made of various materials (resin composites and an ormocer). The curing light type proved influential (LED induced less deformation), as did the restorative materials. The curing protocol of using a halogen curing unit (standard vs soft-start) had no influence on cuspal deformation37; however, microleakage was observed to be inversely proportional to cuspal deformation, even though the authors could not explain the possible link between lower deformation and higher leakage.

Comparison of Materials and Brands

The influence of the composition of the matrix resin was also evaluated to assess cuspal flexure following the placement of each composite layer as well as after treatment completion. It was shown that the classical bisphenol A diglycidyl ether dimethacrylate and triethylene glycol dimethacrylate (TEGMA) resin blend augmented cuspal flexure compared to ethoxylated bisphenol A glycol dimethacrylate (Bis-EMA) and urethane dimethacrylate (UDMA ) compositions.55 However, the authors did not comment on the material E-modulus, which largely differed among the tested materials and which is also likely to have influenced tooth deformation.

Electronic speckle pattern interferometry (ESPI) proved to be a viable method with which to monitor tooth dimensional changes during composite placement as the device doesn't contact the tooth.56 The same authors also measured the influence of various composite systems on cuspal deflection following a single increment placement in 2 × 2.5 × 11-mm MOD cavities. The least amount of deformation was recorded with the experimental silorane system, while the flowable composite did not induce more deformation than a conventional hybrid. Among the nano-hybrid materials, variable, cumulative cusp displacement was also recorded, though it was significantly less than that associated with the conventional hybrid. The stiffness of the material proved once again to influence the reaction to composite polymerization shrinkage.

Fleming and coworkers55,57 compared previous data obtained with a halogen light-curing unit (LCU) to new data generated with LED technology. Despite large numerical differences in favor of the ormocer material compared to the Z100 system, no statistical significance was revealed between both of these light-curing technologies.37 The same authors investigated the cuspal deformation of experimental oxirane and silorane materials and compared it to that of monomodal composite systems (Z100 and Z250, 3M).41 They observed a significant reduction in cuspal deflection with the oxirane and then the silorane but with, respectively, an increase or no difference in microleakage values. The authors then put the relative “impact” of cuspal deformation on cavity seal into perspective.

Conclusion: Tooth Deformation and Shrinkage Stress

The cavity size and design (configuration factor) as well as material physico-chemical composition (filler and matrix and consequently the material's stiffness) proved to influence tooth deformation and stress development within the tooth structure or the restorative interface. When considering the design of the studies under review, the quality of the evidence has to be considered to be high, with good consistency. The light curing type (LED vs halogen) only proved to influence cuspal deformation (less deformation for LED curing) in some studies but had no influence on microleakage. The curing mode (soft-start vs conventional curing mode with halogen LCU) had no influence on either of these parameters. Therefore, the ability of a hypothetically “improved” curing approach, such as soft-start curing, appeared to be ineffective in reducing tooth deformation, while an extended curing time with continuous, lower irradiance did demonstrate reduced tooth deformation, even though it was tested in a different experimental setup. With regard to these hypotheses about curing modality, the quantity and consistency of the evidence were rather limited.

Conclusion: Tooth Deformation and Shrinkage Stress Methodology

The tooth deformation observed following the placement and polymerization of various composite materials and curing protocols validates the results obtained by FEM studies. Therefore, when measurements produced on natural teeth are compared to FEM, it confers on these tests a high quality of evidence. The ESPI approach without direct interference with the restored tooth appears to be a promising alternative to conventional strain gauges.

III. Microtensile and Shear Tests

The adhesion studies that were reviewed are presented in Table 3.

Table 3:  Selected References for Microtensile and Shear Bond Strength
Table 3: 

Comparison of Restorative and Layering Techniques

Several studies compared the influence of layering vs bulk-fill approaches on dentin bond-strength (BS). They all concluded that a bulk-fill technique did lead to lower bond strength compared to restorations placed incrementally.58-61 The results regarding the influence of different layering approaches proved rather controversial, with some studies59 showing higher bond strength values for the horizontal technique, while two other studies58,60 concluded that there was no difference between horizontal and oblique or vertical layering techniques. When combining three to four horizontal and oblique layers in different geometries, the highest microtensile bond strength (MTBS) values were observed with the four increments. All other combinations of three horizontal and oblique layers exhibited similar MTBS values, and all were lower that that observed for four increments.62

Other Restorative Variables (Cervical Margin Position, Cavity Dimensions, and C-Factor)

Cavity depth proved influential for bond strength, with lower values in deep dentin and the highest values observed on a flat preparation with low C-factor (CF=1). When a higher C-factor (CF=3) was used, all values fell, which demonstrated the impact of restricted free-surface and composite flow.63 Consequently, the C-factor, and therefore bond strength, also proved to influence failure modes at the adhesive interface.63 The cavity size was also shown to be an influential factor for dentin adhesion, and with an appropriate layering technique the negative impact of larger cavity dimensions could be counteracted.61 When attempts were made to evaluate the impact of preparation wall location (gingival, pulpal, and axial) on MTBS, no trend was found. The results actually demonstrated that adhesion was influenced by the adhesive system rather than by the preparation surface or location.64

Sandwich Techniques

In one study,58 the presence of a flowable resin composite (FRC) liner did not improve MTBS in Class II cavities restored incrementally using either a horizontal or oblique layering technique. In another study,65 the differences in MTBS were specific to the product rather than influenced by the presence of a flowable composite liner underneath bulk or incrementally filled restorations. It was observed that a lining of FRC improved adhesion when vertical or oblique layering techniques were applied but had no apparent effect underneath horizontal increments. Once again, these findings were product specific.59 Other authors concluded again that the use of a FRC liner alone did not improve MTBS underneath bulk-filled restorations with a high C-factor, while the presence of fibers or a combination or FRC together with fibers did increase MTBS.66 Incorporation of glass fibers also showed stable BS values regardless of the C-factor.66

Polymerization Protocol

Incremental techniques provided better MTBS than did bulk filling for the two different irradiation modes tested (continuous and stepped). MTBS values on flat dentin specimens were also higher than in a Class I cavity configuration, with the exception of the combination of incremental technique and stepped curing mode.60 Different combinations of light sources (plasma, halogen and LED) were used to cure the dentin bonding agent (DBA) and composite in Class I cavities, and this revealed the significant influence of irradiation conditions. Overall, bond strength was more dependent on the light source used for curing the DBA rather than that used for curing the composite. In this study, the LED curing of the DBA together with halogen curing of the restorative composite produced the lowest MTBS values.67

Comparison of Materials

Two adhesive systems (self-etch one and two step) were tested after mechanical and thermal fatigue. The one-step system presented lower MTBS values and more than 50% of sample debonding during the testing, which was presumably due to an overwet phenomenon. In this study,68 the short period of mechanical loading (50,000 cycles) did not influence the results. In an attempt to evaluate the impact of contact time of the primer on the tooth substrate, additional priming times of 30, 60, and 120 seconds were added after normal application duration, but these did not influence MTBS, as measured on the gingival wall of Class II cavities.69 In another study70 from the same authors, it was concluded that MTBS values were not influenced by location (pulpal or gingival wall) for the various adhesives tested. However, the three-step total-etch, water-based adhesive and the two-step acetone-based prime and bond systems produced lower values than the two-step water-based self-etch and two-step total-etch ethanol-based systems.70

Several composite types and brands were tested for polymerization shrinkage and their interface quality, microhardness profile, flexural strength, and elasticity-modulus following a bulk application in a Class I configuration. It was found that MTBS was correlated to elasticity modulus and the velocity of contraction stress development within restrictive cavity configuration.71 Therefore, one cannot predict that a high MTBS will be based only on a low E-modulus since the polymerization kinetics play an important role in the development of interfacial stresses and adhesion.71

Indirect Restorations

Various adhesives (one-step, two-step, and three-step systems) were compared following two modes (pre-cured or non–pre-cured) before the placement of indirect composite inlays. The effect of pre-curing appeared to be material and location specific, and the thickness of the adhesive layer appeared to be increased in the case of pre-curing.72 However, the relevance of the aforementioned results in relation to pre-curing the adhesive system for the cementation of indirect restorations would seem to be dubious since the concept of “dual bonding”73 was not fully implemented in this study (adhesive layer thinned and light-cured just prior to adhesive cementation). This latter concept is also supported by more recent results65,74 obtained on flat dentin or overlay-like preparations demonstrating that light-activation of the adhesive layer before indirect cementation, renamed “immediate dentin sealing,” is crucial to obtaining high MTBS.

The presence of temporary cement used for the interim restoration reduced MTBS values in Class I inlays, and to overcome this effect, cleaning of the cavity or immediate dentin sealing was needed.75 The removal of cement excesses with a scaler or air polishing with a soft glass were effective treatments, while another air-polishing paste with round particles was unable to restore good MTBS values.75

Comparison of Direct and Indirect Techniques

The effect of cyclic loading was evaluated on direct and indirect Class II composite restorations. It was shown76 that next to marginal adaptation, MTBS values were superior in the indirect group. When evaluating the influence of different gererations of adhesives (third self-etch, fourth total etch, and fifth one bottle) in combination with direct composite and indirect ceramic restorations, the former multistep adhesive generations produced higher bond strengths, while the pre-curing of the adhesive before cementation of indirect restorations also increased the bond strength.77 In a similar study configuration,78 with simplified cavity design, the dual bonding concept once again noticeably increased the bond strength at buccal walls while reducing MTBS at pulpal walls. When interposing a layer of low-viscosity resin composite, the bond strength measurements were significantly lowered as a result of cohesive fractures in the low-filled liner. Interestingly, a comparison79 between in vivo and in vitro MTBS bond strength on axial and gingival walls demonstrated lower values in vivo, which were particularly pronounced at the gingival walls, most likely as a result of higher substrate wetness.

Conclusion: Microtensile and Shear Tests

Within the limitations of this study protocol, the most relevant conclusions, based on a satisfactory quantity and consistency of the evidence, are that

  • higher bond strengths were obtained with layering techniques (vs bulk);

  • for indirect restorations, “dual bonding” or “immediate dentin sealing,” as opposed to an application and curing of the DBA just before placing the restoration, increased bond strength; and

  • the cavity C-factor is an influential factor for bond strength (high CF reduces MTBS).

All other study variables, including curing protocols, cavity depth, the presence of flowable composite liner, light source, and various adhesive systems, did not have a clear impact on MTBS, and, therefore, no recommandationscan can be drawn as a result of the limited evidence related to quantity and consistency.

Conclusion: Microtensile and Shear Test Methodology

Bond strength and, in particular, microtensile bond strength tests measure the capacity of an adhesive interface to resist stresses induced by polymerization and occlusal function. They actually represent the first attempt to evaluate the potential of a specific restorative system or technique to establish the biomechanical balance needed to maintain sealed margins and reinforce the remaining tooth structure. Such features are crucial in Class I and II adhesive restorations in order to obtain satisfactory medium- and long-term clinical behavior. When combined with mechanical and thermal stressing (oral environment simulation), MTBS tests most likely increase their potential clinical relevance and adequately complement marginal adaptation studies. MTBS also have the potential to measure regional variations of bond strength, something that was not possible with conventional tensile or shear bond strength tests. However, this latter potential ability requires more investigation. The MTBS methodology does potentially suffer from tissue inhomogeneity, but on the other hand, it provides a precise, quantitative evaluation method, which confers an acceptable quality of evidence.

IV. Marginal Adaptation

The marginal adaptation studies that were reviewed are presented in Table 4.

Table 4:  Selected References for Marginal and Internal Adaptation
Table 4: 

Comparison of Restorative and Layering Techniques

In the absence of mechanical loading, two studies80,81 did not find any significant difference in marginal adaptation between bulk-fill and layering techniques, while a third report82 presented opposing findings of significantly more cervical defects in the bulk-fill technique group. In proximal microcavities, more sophisticated filling techniques, such as the three-site layering concept and ceramic inserts, did not show any advantage over a simple two-layer technique using either a restorative or flowable composite.83 Accordingly, “overengineering” the restorative technique appeared useless for small volumes.

In an attempt to evaluate the benefit of additional retentions in small box preparations simulating restoration repair, the smallest box-only composite additions (without undercuts or occlusal retentions) provided the best resistance to cyclic loading.84

Other Restorative Variables (Cervical Margin Position, Cavity Dimensions, Matrix Systems, etc)

The beveling of margins proved beneficial to marginal adaptation,83,85,86 but mainly when enough tissue remained above the cemento-enamel junction.87,88 When less than 1 mm of enamel height remained, the bevel no longer had a positive influence, and in such situations, an indirect technique provided better adaptation.87 The instruments used for finishing and beveling margins proved to be influential with regard to marginal adaptation. Specifically, ultrasonic-driven instruments induced more marginal defects compared to sonic instruments83,85 or a fine diamond round bur.83 The vibration induced by ultrasonic energy during composite placement also proved to be beneficial for Class II adaptation of nonbeveled cavities.85

Sandwich Techniques

Sandwich techniques with conventional glass ionomer cement as a lining downgraded the adaptation to dentin when compared to full composite restorations87,88 or sandwich restorations using resin modified glass ionomer cement (rmGIC) liner or full composite restoration.89 A rmGIC liner or base did show90 the potential to improve marginal adaptation in vitro. The same potential was also demonstrated by a compomer; however, the adaption was only improved in a closed sandwich configuration.86,91,92 But the rationale for using a fluoride-releasing material in an open sandwich configuration was finally questioned, as literature reviews93,94 have not confirmed the protective role of GICs against recurrent caries. Other materials, such as chemically curing or flowable composites, were considered to facilitate restoration placement and/or reduce the negative impact of polymerization shrinkage. This literature review found that the presence of either a flowable liner or chemically curing composite base actually improved marginal adaption, but without totally suppressing marginal defects.77,84,95,96 The aforementioned findings were confirmed recently another study,97 which showed a significant reduction of imperfect margins after loading when applying rmGIC or flowable composite liners with lower E-modulus. In another study,98 a positive effect was only observed when a thin, pre-cured flowable composite lining was applied. The cervical gap size in lined composite restorations was linearly correlated to the strain absorption capacity (negative correlation) and shrinkage (positive correlation).

Influence of Polymerization Protocol

It was first suggested by Goracci and de Martinis99 that a slow polymerization mode could reduce marginal defects in Class II restorations. Since then, only a few reports have evaluated and confirmed the impact of curing protocol on the quality of adaptation in the Class II restoration. The adaptation to enamel of Class II MOD restorations was not influenced by the curing light energy (medium intensity conventional halogen or high-intensity plasma), while the step-curing protocol produced better occlusal and cervical adaption than did pulse-delay or ramp-curing protocols.100 This partially supports other in vitro studies in which the authors studied the effect of various polymerization protocols on contraction force101 or distribution.19 In an attempt to confirm the advantage of the three-sided light-curing protocol over a conventional occlusal curing, it was shown that a reduced light intensity is likely to be the influential factor that improves restoration adaptation.102 In a recent study,103 the impact of curing time and energy density on contraction stress and marginal adaptation was evaluated. It was shown that a minimal radiant exposure was needed to reach a satisfactory adaption and that a further increase in light density did not significantly affect contraction stress or adaptation. Nevertheless, relevant and conclusive studies clarifying the role and potential impact of curing protocols and light intensity on marginal adaptation are still needed.

Comparison Between Adhesive and Composite Types or Systems

Marginal adaptation to enamel was not affected by gingival fluid contamination when this happened just after acid etching. However, gingival fluid did adversely affect adaption when the contamination happened after adhesive placement.104 These results should not necessarily be considered valid for blood or saliva contamination.

The use of a filled adhesive system improved the marginal and internal adaptation of mixed Class II cavities when compared to a nonfilled, thinner “prime and bond” adhesive system. The thicker and consequently elastic bonding resin was considered to act as a stress-breaking layer.91 The performance of simplified adhesive systems used with their respective composite also proved inferior to the multicomponent system that served as the control.105

The comparison between ormocers and a traditional hybrid composite used in Class II cavities was clearly in favor of the hybrid composite, which presented very high percentages of perfect adaptation both in occlusal and cervical enamel. The adhesive used for the ormocer tested in this study was believed to be responsible for the unsatisfactory adaptation observed with the ormocer.106 The influence of ceramic inserts on proximal adaptation of Class II restorations was dependant on the level of the cervical margin and the type of insert used.107 Anatomically shaped inserts improved adaptation to enamel only, while round-shaped, beta-quartz inserts had no influence at all on adaptation when compared to full composite restorations. In dentin, the inserts had no positive impact on restoration quality.

Indirect Composite Restorations

The influence of resinous bases with increasing E-modulus underneath Class II MOD composite inlays was evaluated after mechanical loading. The best results were obtained with a “highly filled” flowable material, while the restorations having no base, a compomer, or a “low-filled” flowable or a restorative material lining showed more marginal defects.92 These results indicated that material mechanical properties such as rigidity/elasticity and viscosity have the potential to influence restoration adaptation after loading. It is interesting to mention that these differences appeared only after loading, which supports the use of cyclic loading to evaluate the impact of different materials or treatment protocols on Class II restoration adaptation and quality.

Comparison Between Direct and Indirect Class II Restorations

In the presence of thin cervical enamel (0.5-mm thickness and 1-mm height) the indirect composite restorations had a better adaptation compared to a direct, multilayered composite filling.88 The presence of a bevel also improved the cervical adaptation in both direct and indirect restorations, but only when there was “thick” (>1 mm) enamel remaining. With a butt margin design, thick enamel was beneficial to indirect restorations only.88 In a study88 evaluating the influence of restorative technique (direct vs indirect composites) and liners (GIC or rmGIC), the inlay technique proved overall to be superior to the direct composite option. In this study, the presence of GIC or rmGIC liners lowered the excellent adaption percentages in both direct and indirect restorations. Once again, the benefit of glass ionomers used as liners was not substantiated by in vitro studies when evaluated in a protocol that was more clinically relevant.

The combination of the dual bonding technique (applying the adhesive system before impression or further restorative procedures)73,108 together with an inlay or insert technique yielded better adaptation than did direct or indirect techniques using a conventional adhesive cementation technique (applying the adhesive at the time of cementation).109 In addition, when comparing a direct technique to ceramic inlays using the dual bonding technique, better results were obtained with this latter approach.77 Moreover, in this same study, third- and fourth-generation adhesives showed better performance than did those of the fifth generation. In another test,76 in which the test samples underwent cyclic loading, the performance of composite inlays was observed to be superior to the direct technique. When comparing a direct technique to direct chair-side inlays or laboratory indirect inlays, the lowest amount of gaps was observed in the indirect group. A reduction in gaps was also observed in the direct inlay group compared to the group in which the direct technique was utilized, but this finding was not significant.110

Comparing different inlay materials in mixed Class II cavities (composite, low-fusing ceramic, Spinell and aluminous porcelains) did not show any significant difference in either marginal or cervical adaptation between these three ceramic materials, which had differing structure and stiffness.109 The composite inlay, however, showed a better marginal adaptation in cervical dentin. In a similar study, the cement type appeared to be the influential factor for cervical adaptation to dentin. Better cervical adaptation to dentin was also observed with ceramic inlays compared to a direct technique, athough once again, this was dependant on the luting material.1,110

Finally, it was observed that the proportion of gap-free resin-dentin interface was not influenced by the restorative technique (direct or CEREC inlay) but instead by the presence of a low-elasticity flowable composite liner, which significantly decreased the amount of defects at the same interface.111

Evaluation of Marginal and Internal Adaptation of Class II Restorations Following Short-term Clinical Function

An interesting approach to testing the marginal and internal adaptation of Class II adhesive restorations was developed by van Dijken and coworkers.112 They sought to integrate the clinical environment and strains, and their concept was to restore premolars scheduled to be extracted (one month after restoration placement) for orthodontic reasons and then to apply the same evaluation protocol as was used for in vitro investigations.112 This approach confirmed the advantage of using a multicomponent adhesive system over a simplified one, and it also verified that the directed shrinkage technique (placing a base of self-curing composite underneath a light-curing restorative material) produced a dentin adaptation that was comparable to that obtained using a horizontal multilayering technique.112 The adaptation for sandwich restorations using a compomer or rmGIC base was superior to full composite restorations after this short period of clinical service113,114 and confirmed the findings of many in vitro investigations.89-91 However, it has to be considered that these findings were not confirmed after longer in vivo observation periods.115,116 Using the same protocol, the one-month adaption of Class II restorations with a FRC was observed to be equivalent to a full composite filling. Using this same test model and time frame, no influence on restoration adaptation was reported117 between a soft-start curing and continuous irradiation curing technique.

Conclusion: Marginal Adaptation

Within the limitations of this study protocol, the most relevant conclusions based on a satisfactory quantity and consistency of the evidence are that

  • the position of restorative margins influenced the marginal adaptation (less defects observed at enamel margins);

  • a bevel improved cervical adaptation in both direct and indirect restorations when enough enamel was present (>1 mm);

  • the dual bonding technique (application of the adhesive system before impression and cementation) improved restoration adaptation;

  • multicomponent adhesive systems showed better margins than did simplified ones;

  • the use of a FRC with low E-modulus or a chemically curing composite base showed a potential for better marginal adaption underneath both direct and indirect restorations; and

  • a better overall adaptation was obtained with indirect techniques.

The influence on marginal adaptation of other variables, such as the filling technique, the curing protocol and light intensity, the presence of a GIC or rmGIC liner, or the composite type used for direct restorations or material type (composites or ceramics) for indirect restorations, could not be ascertained as a result of the insufficient quantity or consistency of the available evidence.

Conclusion: Marginal Adaptation Methodology

Phenomena such as nano-leakage, leakage, pulpal complications, and secondary caries, which are induced by interface breakdown, represent the majority of clinical failures observed in all types of direct restorations.3,118 Therefore, evaluating the behavior of adhesive restorations and interfaces with natural tissues under simulated function, pulpal pressure, and a moist environment helps to identify weak points and allows a better understanding of how to reduce the incidence of defects around or underneath a restoration.92,119-121 This undoubtedly confers upon such a research approach the highest quality among all protocols used to test Class II restorations.

In fact, observing the restoration marginal adaptation without mechanical loading will only reflect the behavior of the system used to fabricate the restoration or placement/insertion stresses and will not provide information about the reaction of the overall system to function. Studies86,92,109,122 using multiple loading cycle steps have actually shown the impact of mechanical load magnitude and stress duration on the quality of marginal and internal adaptation of the restoration. For instance, a restorative system that exhibited a good immediate adaptation due to the increased flexibility of the liner later showed an unsuccessful behavior due to increased deformation under load and adverse behavior to fatigue once it was mechanically stressed. In other words, satisfactory initial adaptation of a restorative system can neither predict an optimal clinical behavior nor inform us about the reaction to long-term functional stresses or the oral cavity environment. The effect of long-term exposure to moisture is also an important test condition in order to reveal phenomena such as hydrolytic degradation and expansion of the restorative system due to water sorption.115,116,123 The limited duration of in vitro investigations therefore still represents a weak aspect of such testing protocols and further justifies the need for in vivo trials, despite their numerous aforementioned practical limitations.

The sensitivity threshold and overall “quality” of evidence for marginal adaptation protocols should also be addressed, as procedural confounders exist for the laboratory stages (ie, control of sample moisture, polishing technique, experience of the operator, real load applied, etc), all of which can affect the significance of some studies and explain the conclusions of a recent and controversial review124 questioning the relevance of marginal-internal adaptation tests of Class V restorations. As a result, the “apparent” absence of a correlation between clinical and in vitro studies regarding the performance of Class V restorations was erroneously interpreted as a possible irrelevance of marginal leakage tests instead of as an indication that confounders and sensitivity issues exist, which affect both the in vitro and clinical studies under review. This underlines once again the importance of extremely well-standardized study protocols and proper simulation of the oral environment (ie, functional loading) for in vitro trials.

V. Comparison of Methods and Evidence Hierarchy for In Vitro Trials

Clinically, restorations can potentially fail because of restoration/tooth fracture, loss of anatomy and function (chemical and mechanical wear), or interface degradation, leading to marginal leakage, pulpal pathology, and recurrent decay. Such failures are therefore of three types: structural breakdown, surface degradation, or loss of cohesiveness between the restoration and tooth structure. Oral cavity strains responsible for those failures are of a mechanical, chemical, thermal, and bacteriological nature. In addition, the repetitive occurrence of those stresses, known as “fatigue,” is of particular importance for both in vivo and in vitro research.125 Therefore, the best approach to evaluate the ability of a restorative system to resist such strains and degradation patterns is a clinical trial, and scientists and clinicians thus continue to call for medium- to long-term studies to discriminately appraise the various operative protocols and material choices. Unfortunately, clinical evaluation times shorter than three to five years126,127 seem insufficient, and this strengthens the need for preclinical, in vitro evaluation protocols.126-128

In a similar fashion to the accepted hierarchy of evidence in clinical research, there is also an obvious and increasing need to assess the relevance of laboratory protocols. Therefore, a first important consideration is to evaluate the capacity of in vitro tests for adhesive posterior restorations to replicate major oral strains, such as functional forces, thermal changes, and moist environment. This represents the initial rationale and assessment model for developing a hierarchy of the predictive value or evidence level of in vitro trials, such as we have proposed in Table 5.

Table 5:  Proposed Hierarchy of Evidence for Class II In Vitro Trials, Based on the Capacity of the Laboratory Protocol to Simulate Oral Cavity Strains. Relevance or Hierarchy Degree Is Ranked on a 1-5 Scale, 5 Being the Highest Score
Table 5: 

For instance, resistance to fracture tests without cyclic stressing induce fracture patterns that are irrelevant to the failures observed clinically and were therefore attributed the minimal score (1). As well, microleakage tests, which show poorly consistent results and use a semiquantitative evaluation scale, were also considered poorly relevant to clinical conditions and were thus given scores of 1 or 2 when thermal cyclicor mechanical loading was used. Photoelasticity also suffers from main technological limitations, as previously described, and it was thus also attributed a low relevance score (2). Despite the fact that the evaluation of wear in contact areas following cyclic loading was not reported in this review (as the related references were not in the selected review period), this methodology was attributed a high score of relevance (4), even though wear resistance tests appear nowadays to be less crucial as a result of the considerable improvements in the physical properties of composites.

The reaction of posterior adhesive restorations to intraoral strains is the result of complex interactions among the filling material, the tooth substrate, and their environment. To date, there is no single in vitro test able to simulate all of the aforementioned strains and degradation patterns and then able to reliably predict the clinical performance of a restorative system. Therefore, considering a combination of protocols would appear to be the safest approach at the present time. For instance, information collected from computer simulation (FEM) or tooth deformation (score of 2 to 3 for each) can contribute to a better understanding of stress development and management in adhesive restorations. Bond strength tests (score of 2 to 3) would complete this first level of evaluation by enabling an understanding of how well the adhesive interface reacts to the placement of the restoration and the subsequent functional load.

The second evaluation level would be provided by adaptation studies (score of 3) and, in particular, those studies that submit samples to cyclic loading (scores of 4 to 5). Such protocols appear more discriminative in terms of predicting clinical behavior since they mimic a global interaction of the restorative system with the tooth in a simulated oral environment. They also provide meaningful information about the quality of interfaces following fatigue.88,91,92,120,129-131 However, it may be necessary to perform these studies with an increase of load and number of cycles in order to simulate parafunctional forces and long-term behavior. A force feedback through stress sensors could also improve loading control and should be considered as part of a desired implementation for most of the existing “mastication simulators,” which presently lack such a feedback system.

In clinical studies potential confounders exist. Some of these are sample size, patient selection (ie, age and gender, social background, hygiene, existence of parafunctions, etc), observation period, patient drop-out, clinician skill, and clinical evaluation thresholds, to cite only the most important ones. This logically explains why only multicenter and multioperator, randomized controlled studies with medium- to long-term observation periods are truly conclusive.4-6 The unfortunate reality is that such studies are either totally missing or cannot investigate detailed parameters, such that preclinical, in vitro studies remain a valid and decisive evaluation approach.

In order to improve the quality of the evidence in in vitro trials, hidden or confounding variables thus have to be identified and tentatively eliminated or controlled. Depending on the protocol, those procedural confounds that have to be considered are

  • origin and condition of teeth (human or animal origin, type of teeth, age, presence of decay, storage conditions, etc),

  • control of sample moisture,

  • finishing of the restorations (thermal and mechanical stresses), and

  • control of forces (ie, magnitude, stress profile, frequency).

Therefore, it seems advisable to avoid drawing clinical conclusions from in vitro protocols showing relevance scores that are below 3, unless these are combined with other evaluation methods. Following such a thinking process in dentistry would seem advantageous for editors, reviewers, and readers and would limit the risk of misinterpretation of in vitro research and the subsequent dissemination of insufficiently founded clinical guidelines.

GENERAL CONCLUSIONS

An abundant number of study hypotheses corresponding to almost unlimited combinations of preparation techniques, adhesive procedures, restorative options, and materials were submitted to various in vitro protocols. Some of these hypotheses were repeatedly tested and some consensus arose in regard to the quantity and consistency of the evidence. However, many other combinations remain yet to be validated by either additional in vitro research or clinical trials as a result of the insufficient quantity, quality, or consistency of the available evidence.

The following conclusions can therefore be made based on the systematic conclusiveness of various in vitro studies, and some recommendations can conceptually be made to guide clinicians toward their operative choices, even though some caution might still apply in the absence of absolute confirmation through clinical research.

  1. Stress management remains an issue with modern composite technology because of the substantial volumetric polymerization shrinkage that occurs as a byproduct of this chemistry. As yet, there is no new composite formulation in existence that can significantly limit or totally eliminate shrinkage and still maintain all of the proven performance of hybrid composites, even in in vitro testing situations.

  2. The stresses occuring during restoration placement (direct techniques) or function can be controlled by a number of methods.

  3. The control of curing light energy (low irradiance with extended polymerization time) helps reduce stresses transmitted to the restoration, adhesive interface, and tooth structure. However, the advantages of modified light-curing protocols such as ramp curing, soft-start curing, and step curing were not fully verified.

  4. Multilayering is mandatory for direct restorations. No protocol seems especially superior; however, cavity size and configuration are influential factors.

  5. Dual bonding (IDS) improves the adhesion and adaptation to dentin for indirect techniques.

  6. The “elastic” base lining concept (placement of a stress-breaking layer) proved efficient and superior to “traditional” full composite restoration techniques; however, the thickness and E-modulus of such liners are influential factors.

  7. Indirect restorations proved better than direct ones in most in vitro conditions, when used in large cavities.

  8. The material's stiffness, restoration thickness, and configuration (no coverage, partial coverage, or full occlusal coverage) play a crucial role in treating large cavities or nonvital teeth as a result of the imperative need for tooth stabilization and reinforcement. It seems advisable to use “stiffer” composites or ceramics for restoring weakened posterior teeth, such as those that have been endodontically treated.

Conflict of Interest

The authors of this manuscript certify that they have no proprietary, financial, or other personal interest of any nature or kind in any product, service, and/or company that is presented in this article.

REFERENCES

  • 1
    Manhart J,
    Schmidt M,
    Chen HY,
    Kunzelmann KH,
    &
    HickelR
    (2001) Marginal quality of tooth-colored restorations in Class II cavities after artificial agingOperative Dentistry26(
    4
    ) 357-366.
  • 2
    Manhart J,
    Chen HY,
    Mehl A,
    Weber K,
    &
    HickelR
    (2001) Marginal quality and microleakage of adhesive Class V restorationsJournal of Dentistry29(
    2
    ) 123-130.
  • 3
    Manhart J,
    Chen H,
    Hamm G,
    &
    HickelR
    (2004) Buonocore Memorial Lecture. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentitionOperative Dentistry29(
    5
    ) 481-508.
  • 4
    Group E-BMW (1992) Evidence-based medicine. A new approach to teaching the practice of medicineJournal of the American Medical Association268(
    17
    ) 2420-2425.
  • 5
    Straus SE,
    Richardson WS,
    Glasziou P,
    Haynes RB
    (2005) Evidence-based Medicine: How to Practice and Teach EBM, 3rd ed.
    London
    :
    Elsevier, Churchill Livingstone
    .
  • 6
    Ismail AI
    (2004) Evidence-based dentistryTexas Dental Journal121(
    5
    ) 370-371.
  • 7
    Gyorkos TW TT,
    Abrahamowicz M
    (1994) An approach to the development of practice guidelines for community health interventionsCanadian Journal of Public Health85(Supplement 1) S8-S13.
  • 8
    Higgins JPT,
    Green S,
    editors (2006) Cochrane Handbook for Systematic Reviews of Interventions 4.2.6In: The Cochrane Library, Issue 4.
    Chichester, UK
    :
    John Wiley & Sons, Ltd. 9
    .
    BrissPA,
    ZazaS,
    PappaioanouM,
    FieldingJ,
    Wright-De AgüeroL,
    TrumanBI,
    HopkinsDP MP,
    ThompsonRS,
    WoolfSH,
    Carande-KulisVG,
    AndersonL,
    HinmanAR MD,
    TeutschSM,
    HarrisJR
    (2000) Developing an evidence-based guide to community preventive services—Methods. The Task Force on Community Preventive Services. American Journal of Preventive Medicine1835-43.
  • 9
    Guyatt GH,
    Haynes RB,
    Jaeschke RZ,
    Cook DJ,
    Green L,
    Naylor CD,
    Wilson MC,
    &
    RichardsonWS
    (2000) Users' Guides to the Medical Literature: XXV.
    Evidence-based medicine
    :
    Principles for applying the Users' Guides to patient care
    . Evidence-Based Medicine Working Group. Journal of the American Medical Association 284 1290-1296.
  • 10
    Harris RP,
    Helfand M,
    Woolf SH,
    Lohr KN,
    Mulrow CD,
    Teutsch SM,
    &
    AtkinsD
    (2001) Current methods of the U.S.
    Preventive Services Task Force
    :
    A review of the process American Journal of Preventive Medicine 20 21-35
    .
  • 11
    West S,
    King V,
    Carey TS,
    et al
    . (2002) Systems to Rate the Strength of Scientific Evidence. Evidence Report/Technology Assessment No. 47 (Prepared by the Research Triangle Institute–University of North Carolina Evidence-based Practice Center under Contract No. 290-97-0011). AHRQ Publication No. 02-E016.
    Rockville, MD
    :
    Agency for Healthcare Research and Quality
    .
  • 12
    Kinomoto Y,
    &
    ToriiM
    (1998) Photoelastic analysis of polymerization contraction stresses in resin composite restorationsJournal of Dentistry26(
    2
    ) 165-171.
  • 13
    Kinomoto Y,
    Torii M,
    Takeshige F,
    &
    EbisuS
    (1999) Comparison of polymerization contraction stresses between self- and light-curing compositesJournal of Dentistry27(
    5
    ) 383-389.
  • 14
    Kinomoto Y,
    Torii M,
    Takeshige F,
    &
    EbisuS
    (2000) Polymerization contraction stress of resin composite restorations in a model Class I cavity configuration using photoelastic analysisJournal of Esthetic Dentistry12(
    6
    ) 309-319.
  • 15
    Jedrychowski JR,
    Bleier RG,
    &
    CaputoAA
    (1998) Shrinkage stresses associated with incremental composite filling techniquesJournal of Dentistry for Children65(2) 111-115.
  • 16
    Jedrychowski JR,
    Bleier RG,
    &
    CaputoAA
    (2001) Shrinkage stresses associated with incremental composite filling techniques in conservative Class II restorationsJournal of Dentistry for Children68(3)150, 161-167.
  • 17
    Verdonschot N,
    Fennis WM,
    Kuijs RH,
    Stolk J,
    Kreulen CM,
    &
    CreugersNH
    (2001) Generation of 3-D finite element models of restored human teeth using micro-CT techniquesInternational Journal of Prosthodontics14(
    4
    ) 310-315.
  • 18
    Versluis A,
    Tantbirojn D,
    Pintado MR,
    DeLong R,
    &
    DouglasWH
    (2004) Residual shrinkage stress distributions in molars after composite restorationDental Materials20(
    6
    ) 554-564.
  • 19
    Fennis WM,
    Kuijs RH,
    Barink M,
    Fokkinga WA,
    Kreulen CM,
    Creugers NH,
    &
    VerdonschotN
    (2003) A finite element model of a cusp-replacing adhesive restorationNed Tijdschr Tandheelkd110(
    4
    ) 149-153.
  • 20
    Fennis WM,
    Kuijs RH,
    Barink M,
    Kreulen CM,
    Verdonschot N,
    &
    CreugersNH
    (2005) Can internal stresses explain the fracture resistance of cusp-replacing composite restorations?European Journal of Oral Science113(
    5
    ) 443-448.
  • 21
    Xu X,
    Tao L,
    &
    XiongH
    (1999) Three dimensional finite element analysis of effects on composite resin for filling in various cavity margin designZhonghua Kou Qiang Yi Xue Za Zhi34(
    5
    ) 281-283.
  • 22
    Li H,
    Yun X,
    Li J,
    Shi L,
    Fok AS,
    Madden MJ,
    &
    LabuzJF
    (2010) Strengthening of a model composite restoration using shape optimization: A numerical and experimental studyDental Materials26(
    2
    ) 126-134.
  • 23
    Kowalczyk P
    (2009) Influence of the shape of the layers in photo-cured dental restorations on the shrinkage stress peaks-FEM studyDental Materials25(
    12
    ) e83-e91.
  • 24
    Kuijs RH,
    Fennis WM,
    Kreulen CM,
    Barink M,
    &
    VerdonschotN
    (2003) Does layering minimize shrinkage stresses in composite restorations?Journal of Dental Research82(
    12
    ) 967-971.
  • 25
    Ausiello P,
    Apicella A,
    Davidson CL,
    &
    RengoS
    (2001) 3D-finite element analyses of cusp movements in a human upper premolar, restored with adhesive resin-based compositesJournal of Biomechanics34(
    10
    ) 1269-1277.
  • 26
    Ensaff H,
    O'Doherty DM,
    &
    JacobsenPH
    (2001) The influence of the restoration-tooth interface in light cured composite restorations: A finite element analysisBiomaterials22(
    23
    ) 3097-3103.
  • 27
    Ausiello P,
    Apicella A,
    &
    DavidsonCL
    (2002) Effect of adhesive layer properties on stress distribution in composite restorations—A 3D finite element analysisDental Materials18(
    4
    ) 295-303.
  • 28
    Magne P,
    &
    BelserUC
    (2003) Porcelain versus composite inlays/onlays: Effects of mechanical loads on stress distribution, adhesion, and crown flexureInternational Journal of Periodontics and Restorative Dentistry23(
    6
    ) 543-555.
  • 29
    Ausiello P,
    Rengo S,
    Davidson CL,
    &
    WattsDC
    (2004) Stress distributions in adhesively cemented ceramic and resin-composite Class II inlay restorations: A 3D-FEA studyDental Materials20(
    9
    ) 862-872.
  • 30
    Belli S,
    Eskitascioglu G,
    Eraslan O,
    Senawongse P,
    &
    TagamiJ
    (2005) Effect of hybrid layer on stress distribution in a premolar tooth restored with composite or ceramic inlay: An FEM studyJ Biomed Mater Res B Appl Biomater74(
    2
    ) 665-668.
  • 31
    Yamamoto T,
    Takeishi S,
    &
    MomoiY
    (2007) Finite element stress analysis of indirect restorations prepared in cavity basesDental Materials Journal26(
    2
    ) 274-279.
  • 32
    Magne P
    (2007) Efficient 3D finite element analysis of dental restorative procedures using micro-CT dataDental Materials23(
    5
    ) 539-548.
  • 33
    Marotta Araujo R, da Silva Filho FP, & Dias Mendes AJ (1990) Marginal leakage in composite resin restorations in posterior teeth. Effect of material, cavity preparation and enamel conditioning at the cervical levelRev Odontol UNESP19(
    1
    ) 191-201.
  • 34
    Hilton TJ,
    &
    FerracaneJL
    (1999) Cavity preparation factors and microleakage of Class II composite restorations filled at intraoral temperaturesAmerican Journal of Dentistry12(
    3
    ) 123-130.
  • 35
    Uctasli S,
    Shortall AC,
    &
    BurkeFJ
    (2002) Effect of accelerated restorative techniques on the microleakage of Class II compositesAmerican Journal of Dentistry15(
    3
    ) 153-158.
  • 36
    Fleming GJ,
    Khan S,
    Afzal O,
    Palin WM,
    &
    BurkeFJ
    (2007) Investigation of polymerisation shrinkage strain, associated cuspal movement and microleakage of MOD cavities restored incrementally with resin-based composite using an LED light curing unitJournal of Dentistry35(
    2
    ) 97-103.
  • 37
    Demarco FF,
    Ramos OL,
    Mota CS,
    Formolo E,
    &
    JustinoLM
    (2001) Influence of different restorative techniques on microleakage in Class II cavities with gingival wall in cementumOperative Dentistry26(
    3
    ) 253-259.
  • 38
    Aranha AC,
    &
    PimentaLA
    (2004) Effect of two different restorative techniques using resin-based composites on microleakageAmerican Journal of Dentistry17(
    2
    ) 99-103.
  • 39
    Civelek A,
    Ersoy M,
    L'Hotelier E,
    Soyman M,
    &
    SayEC
    (2003) Polymerization shrinkage and microleakage in Class II cavities of various resin compositesOperative Dentistry28(
    5
    ) 635-641.
  • 40
    Palin WM,
    Fleming GJ,
    Nathwani H,
    Burke FJ,
    &
    RandallRC
    (2005) In vitro cuspal deflection and microleakage of maxillary premolars restored with novel low-shrink dental compositesDental Materials21(
    4
    ) 324-335.
  • 41
    Shor A,
    Nicholls JI,
    Phillips KM,
    &
    LibmanWJ
    (2003) Fatigue load of teeth restored with bonded direct composite and indirect ceramic inlays in MOD Class II cavity preparationsInternational Journal of Prosthodontics16(
    1
    ) 64-69.
  • 42
    Fennis WM,
    Kuijs RH,
    Kreulen CM,
    Verdonschot N,
    &
    CreugersNH
    (2004) Fatigue resistance of teeth restored with cuspal-coverage composite restorationsInternational Journal of Prosthodontics17(
    3
    ) 313-317.
  • 43
    Kuijs RH,
    Fennis WM,
    Kreulen CM,
    Roeters FJ,
    Verdonschot N,
    &
    CreugersNH
    (2006) A comparison of fatigue resistance of three materials for cusp-replacing adhesive restorationsJournal of Dentistry34(
    1
    ) 19-25.
  • 44
    Magne P,
    &
    OganesyanT
    (2009) Premolar cuspal flexure as a function of restorative material and occlusal contact locationQuintessence International40(
    5
    ) 363-370.
  • 45
    Magne P,
    &
    KnezevicA
    (2009) Thickness of CAD-CAM composite resin overlays influences fatigue resistance of endodontically treated premolarsDental Materials25(
    10
    ) 1264-1268.
  • 46
    Magne P,
    &
    OganesyanT
    (2009) CT scan-based finite element analysis of premolar cuspal deflection following operative proceduresInternational Journal of Periodontics and Restorative Dentistry29(
    4
    ) 361-369.
  • 47
    Magne P,
    &
    KnezevicA
    (2009) Simulated fatigue resistance of composite resin versus porcelain CAD/CAM overlay restorations on endodontically treated molarsQuintessence International40(
    2
    ) 125-133.
  • 48
    Magne P,
    &
    KnezevicA
    (2009) Influence of overlay restorative materials and load cusps on the fatigue resistance of endodontically treated molarsQuintessence International40(
    9
    ) 729-737.
  • 49
    Dietschi D,
    Maeder M,
    Meyer JM,
    &
    HolzJ
    (1990) In vitro resistance to fracture of porcelain inlays bonded to toothQuintessence International21(
    10
    ) 823-831.
  • 50
    Kamel FM,
    Bides MW,
    &
    LeinfelderKF
    (1995) Strain profiles in molars restored with posterior composite resins: Effect of cavity size & restorative techniqueEgypt Dental Journal41(
    3
    ) 1327-1333.
  • 51
    Tantbirojn D,
    Versluis A,
    Pintado MR,
    DeLong R,
    &
    DouglasWH
    (2004) Tooth deformation patterns in molars after composite restorationDental Materials20(
    6
    ) 535-542.
  • 52
    Gonzalez-Lopez S,
    Vilchez Diaz MA,
    de Haro-Gasquet F,
    Ceballos L,
    &
    de Haro-MunozC
    (2007) Cuspal flexure of teeth with composite restorations subjected to occlusal loadingJournal of Adhesive Dentistry9(
    1
    ) 11-15.
  • 53
    Park J,
    Chang J,
    Ferracane J,
    &
    LeeIB
    (2008) How should composite be layered to reduce shrinkage stress: Incremental or bulk filling?Dental Materials24(
    11
    ) 1501-1505.
  • 54
    Fleming GJ,
    Hall DP,
    Shortall AC,
    &
    BurkeFJ
    (2005) Cuspal movement and microleakage in premolar teeth restored with posterior filling materials of varying reported volumetric shrinkage valuesJournal of Dentistry33(
    2
    ) 139-146.
  • 55
    Bouillaguet S,
    Gamba J,
    Forchelet J,
    Krejci I,
    &
    WatahaJC
    (2006) Dynamics of composite polymerization mediates the development of cuspal strainDental Materials22(
    10
    ) 896-902.
  • 56
    Fleming GJ,
    Cara RR,
    Palin WM,
    &
    BurkeFJ
    (2007) Cuspal movement and microleakage in premolar teeth restored with resin-based filling materials cured using a 'soft-start' polymerisation protocolDental Materials23(
    5
    ) 637-643.
  • 57
    Figueiredo Reis A,
    Giannini M,
    Ambrosano GM,
    &
    ChanDC
    (2003) The effects of filling techniques and a low-viscosity composite liner on bond strength to Class II cavitiesJournal of Dentistry31(
    1
    ) 59-66.
  • 58
    Nikolaenko SA,
    Lohbauer U,
    Roggendorf M,
    Petschelt A,
    Dasch W,
    &
    FrankenbergerR
    (2004) Influence of C-factor and layering technique on microtensile bond strength to dentinDental Materials20(
    6
    ) 579-585.
  • 59
    dos Santos AJ,
    Giannini M,
    Paulillo LA,
    Lovadino JR,
    &
    de CarvalhoRM
    (2004) Effect of irradiation mode and filling technique on resin/dentin bonding strength in Class I cavitiesBraz Oral Res18(
    3
    ) 260-265.
  • 60
    He Z,
    Shimada Y,
    &
    TagamiJ
    (2007) The effects of cavity size and incremental technique on micro-tensile bond strength of resin composite in Class I cavitiesDental Materials23(
    5
    ) 533-538.
  • 61
    Niu Y,
    Ma X,
    Fan M,
    &
    ZhuS
    (2009) Effects of layering techniques on the micro-tensile bond strength to dentin in resin composite restorationsDental Materials25(
    1
    ) 129-134.
  • 62
    Yoshikawa T,
    Sano H,
    Burrow MF,
    Tagami J,
    &
    PashleyDH
    (1999) Effects of dentin depth and cavity configuration on bond strengthJournal of Dental Research78(
    4
    ) 898-905.
  • 63
    Cavalcanti AN,
    Mitsui FH,
    Lima AF,
    Mathias P,
    &
    MarchiGM
    (2010) Evaluation of dentin hardness and bond strength at different walls of Class II preparationsJournal of Adhesive Dentistry12(
    3
    ) 183-188.
  • 64
    Cavalcanti SC,
    de Oliveira MT,
    Arrais CA,
    &
    GianniniM
    (2008) The effect of the presence and presentation mode of co-initiators on the microtensile bond strength of dual-cured adhesive systems used in indirect restorationsOperative Dentistry33(
    6
    ) 682-689.
  • 65
    Belli S,
    Donmez N,
    &
    EskitasciogluG
    (2006) The effect of C-factor and flowable resin or fiber use at the interface on microtensile bond strength to dentinJournal of Adhesive Dentistry8(
    4
    ) 247-253.
  • 66
    D'Alpino PH,
    Wang L,
    Rueggeberg FA,
    Svizero NR,
    Pereira JC,
    Pashley DH,
    &
    CarvalhoRM
    (2006) Bond strength of resin-based restorations polymerized with different light-curing sourcesJournal of Adhesive Dentistry8(
    5
    ) 293-298.
  • 67
    Nikaido T,
    Kunzelmann KH,
    Ogata M,
    Harada N,
    Yamaguchi S,
    Cox CF,
    Hickel R,
    &
    TagamiJ
    (2002) The in vitro dentin bond strengths of two adhesive systems in Class I cavities of human molarsJournal of Adhesive Dentistry4(
    1
    ) 31-39.
  • 68
    Purk JH,
    Ganne S,
    Parikh R,
    Dusevich V,
    Glaros A,
    &
    EickJD
    (2004) An in-vitro microtensile test of Scotchbond Multi-Purpose adhesive applied at different priming timesOperative Dentistry29(
    6
    ) 693-697.
  • 69
    Purk JH,
    Healy M,
    Dusevich V,
    Glaros A,
    &
    EickJD
    (2006) In vitro microtensile bond strength of four adhesives tested at the gingival and pulpal walls of Class II restorationsJournal of the American Dental Association137(
    10
    ) 1414-1418.
  • 70
    Ilie N,
    Kunzelmann KH,
    &
    HickelR
    (2006) Evaluation of micro-tensile bond strengths of composite materials in comparison to their polymerization shrinkageDental Materials22(
    7
    ) 593-601.
  • 71
    Coelho Santos MJ,
    Navarro MF,
    Tam L,
    &
    McCombD
    (2005) The effect of dentin adhesive and cure mode on film thickness and microtensile bond strength to dentin in indirect restorationsOperative Dentistry30(
    1
    ) 50-57.
  • 72
    Paul SJ,
    &
    SchaererP
    (1997) The dual bonding technique: A modified method to improve adhesive luting proceduresInternational Journal of Periodontics and Restorative Dentistry17(
    6
    ) 536-545.
  • 73
    Magne P,
    Kim TH,
    Cascione D,
    &
    DonovanTE
    (2005) Immediate dentin sealing improves bond strength of indirect restorationsJournal of Prosthetic Dentistry94(
    6
    ) 511-519.
  • 74
    Frankenberger R,
    Lohbauer U,
    Taschner M,
    Petschelt A,
    &
    NikolaenkoSA
    (2007) Adhesive luting revisited: Influence of adhesive, temporary cement, cavity cleaning, and curing mode on internal dentin bond strengthJournal of Adhesive Dentistry9(Supplement 2) 269-273.
  • 75
    Aggarwal V,
    Logani A,
    Jain V,
    &
    ShahN
    (2008) Effect of cyclic loading on marginal adaptation and bond strength in direct vs. indirect Class II MO composite restorationsOperative Dentistry33(
    5
    ) 587-592.
  • 76
    Frankenberger R,
    Sindel J,
    Kramer N,
    &
    PetscheltA
    (1999) Dentin bond strength and marginal adaptation: Direct composite resins vs ceramic inlaysOperative Dentistry24(
    3
    ) 147-155.
  • 77
    de Andrade OS,
    de Goes MF,
    &
    MontesMA
    (2007) Marginal adaptation and microtensile bond strength of composite indirect restorations bonded to dentin treated with adhesive and low-viscosity compositeDental Materials23(
    3
    ) 279-287.
  • 78
    Purk JH,
    Dusevich V,
    Glaros A,
    Spencer P,
    &
    EickJD
    (2004) In vivo versus in vitro microtensile bond strength of axial versus gingival cavity preparation walls in Class II resin-based composite restorationsJournal of the American Dental Association135(
    2
    ) 185-193;quiz 228.
  • 79
    Tjan AH,
    Bergh BH,
    &
    LidnerC
    (1992) Effect of various incremental techniques on the marginal adaptation of Class II composite resin restorationsJournal of Prosthetic Dentistry67(
    1
    ) 62-66.
  • 80
    Idriss S,
    Habib C,
    Abduljabbar T,
    &
    OmarR
    (2003) Marginal adaptation of Class II resin composite restorations using incremental and bulk placement techniques: An ESEM studyJournal of Oral Rehabilitation30(
    10
    ) 1000-1007.
  • 81
    Stoll R,
    Gente M,
    Palichleb M,
    &
    StachnissV
    (2007) On the effect of an internal light conductor on the marginal integrity of Class-II composite fillingsDental Materials23(
    2
    ) 145-152.
  • 82
    Hugo B,
    Stassinakis A,
    Hofmann N,
    Hausmann P,
    &
    KlaiberB
    (2001) In vivo study of small Class II composite fillingsSchweiz Monatsschr Zahnmed111(
    1
    ) 11-18.
  • 83
    Frankenberger R,
    Roth S,
    Kramer N,
    Pelka M,
    &
    PetscheltA
    (2003) Effect of preparation mode on Class II resin composite repairJournal of Oral Rehabilitation30(
    6
    ) 559-564.
  • 84
    Schmidlin PR,
    Wolleb K,
    Imfeld T,
    Gygax M,
    &
    LussiA
    (2007) Influence of beveling and ultrasound application on marginal adaptation of box-only Class II (slot) resin composite restorationsOperative Dentistry32(
    3
    ) 291-297.
  • 85
    Dietschi D,
    Bindi G,
    Krejci I,
    &
    DavidsonC
    (2002) Marginal and internal adaptation of stratified compomer-composite Class II restorationsOperative Dentistry27(
    5
    ) 500-509.
  • 86
    Dietschi D,
    De Siebenthal G,
    Neveu-Rosenstand L,
    &
    HolzJ
    (1995) Influence of the restorative technique and new adhesives on the dentin marginal seal and adaptation of resin composite Class II restorations: An in vitro evaluationQuintessence International26(
    10
    ) 717-727.
  • 87
    Dietschi D,
    Scampa U,
    Campanile G,
    &
    HolzJ
    (1995) Marginal adaptation and seal of direct and indirect Class II composite resin restorations: An in vitro evaluationQuintessence International26(
    2
    ) 127-138.
  • 88
    Dietrich T,
    Losche AC,
    Losche GM,
    &
    RouletJF
    (1999) Marginal adaptation of direct composite and sandwich restorations in Class II cavities with cervical margins in dentineJournal of Dentistry27(
    2
    ) 119-128.
  • 89
    Dietrich T,
    Kraemer M,
    Losche GM,
    Wernecke KD,
    &
    RouletJF
    (2000) Influence of dentin conditioning and contamination on the marginal integrity of sandwich Class II restorationsOperative Dentistry25(
    5
    ) 401-410.
  • 90
    Dietschi D,
    Monasevic M,
    Krejci I,
    &
    DavidsonC
    (2002) Marginal and internal adaptation of Class II restorations after immediate or delayed composite placementJournal of Dentistry30(
    5-6
    ) 259-269.
  • 91
    Dietschi D,
    Olsburgh S,
    Krejci I,
    &
    DavidsonC
    (2003) In vitro evaluation of marginal and internal adaptation after occlusal stressing of indirect Class II composite restorations with different resinous basesEuropean Journal of Oral Science111(
    1
    ) 73-80.
  • 92
    Randall RC,
    &
    WilsonNH
    (1999) Glass-ionomer restoratives: A systematic review of a secondary caries treatment effectJournal of Dental Research78(
    2
    ) 628-637.
  • 93
    Wiegand A,
    Buchalla W,
    &
    AttinT
    (2007) Review on fluoride-releasing restorative materials—Fluoride release and uptake characteristics, antibacterial activity and influence on caries formationDental Materials23(
    3
    ) 343-362.
  • 94
    Garberoglio R,
    Coli P,
    &
    BrannstromM
    (1995) Contraction gaps in Class II restorations with self-cured and light-cured resin compositesAmerican Journal of Dentistry8(
    6
    ) 303-307.
  • 95
    Belli S,
    Unlu N,
    &
    OzerF
    (2001) Effect of cavity varnish, amalgam liner or dentin bonding agents on the marginal leakage of amalgam restorationsJournal of Oral Rehabilitation28(
    5
    ) 492-496.
  • 96
    Kwon OH,
    Kim DH,
    &
    ParkSH
    The influence of elastic modulus of base material on the marginal adaptation of direct composite restoration Operative Dentistry 35(4) 441-447.
  • 97
    Chuang SF,
    Jin YT,
    Liu JK,
    Chang CH,
    &
    ShiehDB
    (2004) Influence of flowable composite lining thickness on Class II composite restorationsOperative Dentistry29(
    3
    ) 301-308.
  • 98
    Goracci G MG,
    &
    de MartinisL
    (1996) Curing light intensity and marginal leakage of resin composite restorationsQuintessence International27355-362.
  • 99
    Hofmann N,
    &
    HuneckeA
    (2006) Influence of curing methods and matrix type on the marginal seal of Class II resin-based composite restorations in vitroOperative Dentistry31(
    1
    ) 97-105.
  • 100
    Sakaguchi RL,
    Wiltbank BD,
    &
    MurchisonCF
    (2004) Contraction force rate of polymer composites is linearly correlated with irradianceDental Materials20(
    4
    ) 402-407.
  • 101
    Losche GM
    (1999) Marginal adaptation of Class II composite fillings: Guided polymerization vs reduced light intensityJournal of Adhesive Dentistry1(
    1
    ) 31-39.
  • 102
    Prando F
    (2010) influence of energy density delivered by halogen curing unit during photo polymerization on shrinkage kinetics and marginal adaptation of a restorative composite resin.
    Doctoral dissertation
    :
    University of Geneva; No 684
    .
  • 103
    Spahr A,
    Schon F,
    &
    HallerB
    (2000) Effect of gingival fluid on marginal adaptation of Class II resin-based composite restorationsAmerican Journal of Dentistry13(
    5
    ) 261-266.
  • 104
    Gohring TN,
    Schonenberger KA,
    &
    LutzF
    (2003) Potential of restorative systems with simplified adhesives: Quantitative analysis of wear and marginal adaptation in vitroAmerican Journal of Dentistry16(
    4
    ) 275-282.
  • 105
    Kournetas N,
    Chakmakchi M,
    Kakaboura A,
    Rahiotis C,
    &
    Geis-GerstorferJ
    (2004) Marginal and internal adaptation of Class II ormocer and hybrid resin composite restorations before and after load cyclingClin Oral Investig8(
    3
    ) 123-129.
  • 106
    Strobel WO,
    Petschelt A,
    Kemmoona M,
    &
    FrankenbergerR
    (2005) Ceramic inserts do not generally improve resin composite marginsJournal of Oral Rehabilitation32(
    8
    ) 606-613.
  • 107
    Bertschinger C,
    Paul SJ,
    Luthy H,
    &
    ScharerP
    (1996) Dual application of dentin bonding agents: Effect on bond strengthAmerican Journal of Dentistry9(
    3
    ) 115-119.
  • 108
    Dietschi D,
    &
    HerzfeldD
    (1998) In vitro evaluation of marginal and internal adaptation of Class II resin composite restorations after thermal and occlusal stressingEuropean Journal of Oral Science106(
    6
    ) 1033-1042.
  • 109
    Papthanasiou A,
    &
    BardwellD
    (2001) Marginal adaptation of three Class II composite restorative techniques in vitroJournal of the Massachusetts Dental Society50(
    2
    ) 30-32.
  • 110
    Iida K,
    Inokoshi S,
    &
    KurosakiN
    (2003) Interfacial gaps following ceramic inlay cementation vs direct compositesOperative Dentistry28(
    4
    ) 445-452.
  • 111
    van Dijken JW,
    Horstedt P,
    &
    WaernR
    (1998) Directed polymerization shrinkage versus a horizontal incremental filling technique: Interfacial adaptation in vivo in Class II cavitiesAmerican Journal of Dentistry11(
    4
    ) 165-172.
  • 112
    Lindberg A,
    van Dijken JW,
    &
    HorstedtP
    (2000) Interfacial adaptation of a Class II polyacid-modified resin composite/resin composite laminate restoration in vivoActa Odontologica Scandinavica58(
    2
    ) 77-84.
  • 113
    Andersson-Wenckert IE,
    van Dijken JW,
    &
    HorstedtP
    (2002) Modified Class II open sandwich restorations: Evaluation of interfacial adaptation and influence of different restorative techniquesEuropean Journal of Oral Science110(
    3
    ) 270-275.
  • 114
    Andersson-Wenckert IE,
    van Dijken JW,
    &
    KieriC
    (2004) Durability of extensive Class II open-sandwich restorations with a resin-modified glass ionomer cement after 6 yearsAmerican Journal of Dentistry17(
    1
    ) 43-50.
  • 115
    Opdam NJ,
    Bronkhorst EM,
    Roeters JM,
    &
    LoomansBA
    (2007) Longevity and reasons for failure of sandwich and total-etch posterior composite resin restorationsJournal of Adhesive Dentistry9(
    5
    ) 469-475.
  • 116
    Lindberg A,
    van Dijken JW,
    &
    HorstedtP
    (2005) In vivo interfacial adaptation of Class II resin composite restorations with and without a flowable resin composite linerClin Oral Investig9(
    2
    ) 77-83.
  • 117
    Hickel R,
    &
    ManhartJ
    (2001) Longevity of restorations in posterior teeth and reasons for failureJournal of Adhesive Dentistry3(
    1
    ) 45-64.
  • 118
    Roulet J
    (1990) Degradation of Dental Polymers
    Karger
    ,
    Basel, Switzerland
    .
  • 119
    Krejci I,
    Reich T,
    Lutz F,
    &
    AlbertoniM
    (1990) An in vitro test procedure for evaluating dental restoration systems. 1. A computer-controlled mastication simulatorSchweiz Monatsschr Zahnmed100(8) 953-960.
  • 120
    Krejci I,
    Heinzmann JL,
    &
    LutzF
    (1990) The wear on enamel, amalgam and their enamel antagonists in a computer-controlled mastication simulatorSchweiz Monatsschr Zahnmed100(
    11
    ) 1285-1291.
  • 121
    Dietschi D,
    &
    MoorL
    (1999) Evaluation of the marginal and internal adaptation of different ceramic and composite inlay systems after an in vitro fatigue testJournal of Adhesive Dentistry1(
    1
    ) 41-56.
  • 122
    Spencer P,
    Wang Y,
    &
    BohatyB
    (2006) Interfacial chemistry of moisture-aged Class II composite restorationsJ Biomed Mater Res B Appl Biomater77(
    2
    ) 234-240.
  • 123
    Heintze SD,
    Forjanic M,
    &
    RouletFJ
    (2007) Automated margin analysis of contemporary adhesive systems in vitro: Evaluation of discriminatory variablesJournal of Adhesive Dentistry9(
    4
    ) 359-369.
  • 124
    Roulet JF
    (1987) Degradation of dental polymersJournal of Polymer Science Part C: Polymer letters25(
    7
    ) 303-304.
  • 125
    Mjör IA
    (1987) A regulatory approach to the formulation of assessment criteria for posterior composite resinsQuintessence International18(
    8
    ) 537-541.
  • 126
    Leinfelder KF
    (1987) Evaluation criteria used for assessing the clinical performance of composite resins in posterior teethQuintessence International18(
    8
    ) 531-536.
  • 127
    Davidson CL
    (1987) Posterior composites: Criteria for assessment. Discussion and conclusionsQuintessence International18(
    8
    ) 559-560.
  • 128
    Frankenberger R,
    Kramer N,
    &
    PetscheltA
    (1999) Fatigue behaviour of different dentin adhesivesClin Oral Investig3(
    1
    ) 11-17.
  • 129
    Krejci I,
    &
    LutzF
    (1990) In-vitro test results of the evaluation of dental restoration systems. Correlation with in-vivo resultsSchweiz Monatsschr Zahnmed100(
    12
    ) 1445-1449.
  • 130
    Krejci I,
    &
    LutzF
    (1990) In vitro evaluation of two composite material for posterior restorationsStomatol DDR40(
    8
    ) 326-332.
Copyright: Operative Dentistry, Inc. 2013

Contributor Notes

Corresponding author: Rue Barthélémy Menn 19, Geneva, Geneva CH 1205, Switzerland; e-mail: didier.dietschi@unige.ch
Accepted: 29 Nov 2012
  • Download PDF