In Vivo and In Vitro Effects of Chlorhexidine Pretreatment on Immediate and Aged Dentin Bond Strengths
This study evaluated the effect of 2% chlorhexidine (CHX) pretreatment of dentin on the immediate and aged microtensile bond strength (μTBS) of different adhesives to dentin in vivo and in vitro. Class I cavities were prepared in 80 caries-free human third molars of 40 patients in a split-mouth fashion. In each tooth pair, one tooth received 2% CHX pretreatment after which both teeth were randomly assigned to one of the following groups with respect to the type of adhesive system applied: Adper Single Bond 2 (etch-and-rinse), Clearfil SE Bond (two-step self-etch), Clearfil S3 Bond (one-step self-etch), and Adper Prompt-L-Pop (all-in-one self-etch). The teeth were restored with resin composite and extracted for μTBS testing either immediately or after six months in function. In vitro specimen pairs were prepared as with the clinical protocol in intact, freshly extracted human molars, and thereafter, subjected to testing immediately or after 5000× thermocycling. Data were analyzed with four-way analysis of variance (ANOVA). Bonferroni test was utilized for pair-wise comparisons. The immediate bond strength values were significantly higher than “aged” ones for all tested adhesives (p=0.00). The in vitro immediate bond strength values were statistically higher than in vivo bond strength values (p<0.05). While the bond strength of in vitro aged, CHX-treated samples were higher than their in vivo counterparts (p<0.05), no difference was observed in non-CHX treated groups (p>0.05). In the absence of CHX pretreatment, all adhesives showed significantly higher immediate bond strength values than CHX-treated groups, while all “aged”, non-pretreated adhesives exhibited significantly lower bond strength values (both p<0.05). By contrast, chlorhexidine pretreatment resulted in significantly higher aged bond strengths, regardless of the adhesive system and testing condition. Aging-associated decline in dentin bond strength of etch-and rinse and self-etch adhesives can be counteracted by chlorhexidine application.SUMMARY
INTRODUCTION
Resin-dentin bonds are less durable than resin-enamel bonds, which might be one reason for the relatively short lifespan of tooth-colored fillings.1 Degradation of the resin-dentin bond has been associated with water/oral fluid sorption, polymer swelling, and resin leaching in vitro and in vivo.2,3 Endogenous matrix metalloproteinases (MMPs) also appear to be involved in the disintegration of hybrid layers over time.2,4-6 Collagen fibrils exposed during the acid etching procedure become susceptible to hydrolytic and enzymatic degradation, a process mediated by activation of dentin MMPs.4 Likewise, etch-and-rinse adhesives and self-etching adhesives can activate endogenous MMPs during dentin bonding.7-9
Chlorhexidine (CHX) is a nonspecific protease inhibitor10 that can suppress collagenolytic/gelatinolytic activity of dentin matrices.4 As CHX has cationic properties, it can bind electrostatically to negative carboxyl groups and hydroxyl groups of collagen and noncollagenous phosphoproteins in demineralized dentin, as well as electrostatically to phosphate groups in hydroxyapatite crystallites in mineralized dentin. Application of CHX at different concentrations has been shown to maintain the hybrid layer preservation in several in vivo11-13 and in vitro studies.14-16 Based on published data, there appears to be an increasing tendency among clinicians to apply CHX on dentin prior to bonding procedures. It has been recommended to apply CHX on etched dentin in association with etch-and-rinse adhesives, before primer and bonding application.17 The binding of CHX to demineralized dentin is much higher than that to mineralized dentin.18 There are many results of in vitro studies about CHX application before bonding procedure,14-16,19-22 but these results are yet to be verified in vivo. However, the effect of CHX on self-etching adhesives has not been well determined.
Based on these observations, the aim of this clinical and laboratory study was to test the efficacy of 2% CHX pretreatment on the microtensile bond strength (μTBS) of different adhesives to dentin immediately and after aging. The null hypotheses tested were that: 1) CHX pretreatment has no influence on μTBS values to dentin, 2) bond strength is not influenced by in vivo or in vitro testing, and 3) bond strength values are not related to the tested adhesive systems.
METHODS AND MATERIALS
This study was conducted in both laboratory and clinical phases. The in vitro and clinical research protocols and consent forms were evaluated and approved by the Institutional Human Subject Review Committee.
In Vitro Procedures
Eighty freshly extracted intact human third molars were stored in distilled water for up to 30 days. Standardized Class I cavity preparations with 3-mm mesial-distal width, 2-mm buccolingual width, and 2-mm depth were completed using a diamond cylinder bur (Diatech, Swiss Dental Instruments, Heerbrugg, Switzerland) in a water-cooled high-speed handpiece.
The teeth were randomly divided into four groups (n=20) with respect to the type of adhesive system tested: group I, two-step etch-and-rinse (Adper Single Bond 2, 3M ESPE, St Paul, MN, USA); group II, two-step self-etch (Clearfil SE Bond, Kuraray, Tokyo, Japan); group III, one-step self-etch (Clearfil S3 Bond, Kuraray); and group IV, all-in-one self-etch, (Adper Prompt-L-Pop, 3M ESPE). Prior to adhesive application, specimens in each group were further randomly allocated into two subgroups (n=10): (A) no CHX digluconate pretreatment and (B) 2% CHX digluconate pretreatment. In subgroups B, 2% CHX was applied for 30 seconds using a foam pellet saturated with the solution. Excess CHX was blot-dried prior to application of the adhesive. In group I, CHX was applied after the acid-etching procedure, while in groups II, III, and IV, the cavities were treated with CHX prior to the application of the tested self-etch adhesives. In all groups, the cavities were restored with a hybrid resin composite (Filtek Z250, 3M ESPE). The composite was placed in 2-mm thick increments, each light cured with a LED unit for 20 seconds. The main components, modes of application, and batch numbers of the materials used in the present study are shown in Table 1.

Restored teeth were stored in distilled water for 24 hours, after which finishing and polishing procedures were accomplished with diamond burs (Diatech) and flexible disks (Sof-Lex Pop-on, 3M ESPE), respectively. In each subgroup, half of the specimens (n=5) were randomly assigned for immediate bond strength testing (ie, after 24 hours), while the other half was subjected to thermocycling (5000X) in a water bath from 5°C to 55°C with a dwell time of 30 seconds at each temperature and a transfer time of 5 seconds. All specimens were stored in distilled water until bond strength testing.
In Vivo Procedures
Forty 23- to 28-year-old healthy volunteers with a pair of occluding, noncarious, contralateral third molars scheduled for future extraction were enrolled for in vivo sample preparation. Class I cavities conforming to the dimensions of the in vitro counterparts (3 mm mesial-distal, 2 mm buccolingual, 2 mm deep) were prepared in third molars under rubber dam isolation. As with the in vitro part, patients were randomly allocated into four groups with respect to the adhesive system applied: group V, two-step etch-and-rinse (Adper Single Bond 2); group VI, two-step self-etch (Clearfil SE Bond); group VII, one-step self-etch (Clearfil S3 Bond); and group VIII, all-in-one self-etch, (Adper Prompt-L-Pop). For each tooth pair, one tooth received adhesive placement without prior CHX application, while the contralateral molar was pretreated with 2% CHX in accordance with the in vitro specimen preparation protocol. Following adhesive application, the cavities were restored with a hybrid resin composite (Filtek Z250) as with the in vitro specimens, and finishing and polishing procedures were performed after 24 hours. Half of the patients' teeth were extracted after 24 hours for evaluation of immediate bond strength, while the remaining teeth were periodically monitored and extracted six months later. Extracted teeth were stored in distilled water at room temperature until bond strength evaluation.
Microtensile Bond Test
Restored teeth were longitudinally sectioned across the bonded interface using a water-cooled diamond saw in a precision cutting machine (Micracut 201, MetLab Inc, Niagara Falls, NY, USA) to obtain bonded sticks with a cross-sectional area of approximately 1 mm2. The exact dimension of each beam was measured using a digital caliper. Slabs sectioned from the center of each composite restoration were selected. Three beams were selected from each tooth, resulting in 15 beams for each subgroup. Each beam was attached to the test apparatus with a cyanoacrylate adhesive and stressed to failure under tension using a universal testing machine (Micro Tensile Tester, Bisco, Schaumburg, IL, USA) with a 50 kgf load cell and a crosshead speed of 1 mm/min.
The fractured specimens were examined using a stereomicroscope (SZ 61, Olympus, Tokyo, Japan) at 25× magnification. The failure modes were classified and recorded as cohesive (failure within the composite resin or within dentin), adhesive (failure across the bonding interface), or mixed failure.
Scanning Electron Microscopic Evaluation
Two specimens were randomly selected from each group to evaluate the effect of CHX application on resin-dentin interface. As a preparation for scanning electron microscopic evaluation, specimens were first etched with 37% phosphoric acid for 15 seconds followed by 30 seconds rinsing with water. The specimens were fixed in 10% neutral buffered formalin for 24 hours and rinsed in running water for 15 minutes. Then, the specimens were dehydrated in ascending grades of ethanol (25% for 20 minutes, 50% for 20 minutes, 75% for 20 minutes, 95% for 20 minutes, and 100% for 60 minutes) and thereafter, were immersed in hexamethyldisilazane for 10 minutes. Finally, the specimens were placed on a filter paper inside a covered glass vial, and air-dried at room temperature for 12 hours. The specimens were sputter-coated with gold and examined through scanning electron microscopy (SEM).
Statistical Analysis
Statistical analysis of the data was made using four-way analysis of variance (ANOVA). Bonferroni test was utilized for pair-wise comparisons. Results of failure modes were subjected to nonparametric analysis using Pearson chi-square test. All results were analyzed with SPSS 18.0 for Windows (SPSS Inc, Chicago, IL, USA), with the level of significance set at p<0.05.
RESULTS
The μTBS values of test groups are presented in Table 2 as means and standard deviation. All tested variables (type of adhesive, CHX pretreatment, aging, and in vivo/in vitro testing), significantly influenced the dentin bond strength (p<0.05, four-way ANOVA).

For all tested adhesives, the immediate bond strength values were significantly higher than “aged” ones (p=0.00). While CHX pretreated groups showed significantly lower immediate bond strength values (p<0.05), they yielded higher bond strength values in aged samples (p<0.05) (Table 3). There were statistically significant differences between in vitro and in vivo immediate dentin bond strength values for all tested adhesives regardless of CHX pretreatment (p<0.05). While there were significant differences between in vitro and in vivo aged CHX treated samples (p<0.05), no difference was observed in non-CHX treated samples (p>0.05) (Table 4). The fracture mode was predominantly adhesive and mixed, and was similar among the experimental groups (p>0.05).


In Vitro Specimens
In the absence of CHX pretreatment, immediate and aged dentin bond strength values were similar for SB and SE, and for S3 and PLP (p>0.05), with the immediate and aged dentin bond strength of SB and SE being significantly higher than S3 and PLP (p<0.05). CHX pretreatment caused significant differences in immediate dentin bond strength in all groups except between SB and SE (p=0.336). Significant differences were also observed in “aged” CHX-pretreated groups, except between SB and SE, and S3 and PLP (p>0.05) (Table 5).

In Vivo Specimens
In experimental groups that did not receive prior CHX treatment, results were similar as with their in vitro counterparts, with the exception of insignificance between SE and S3. For CHX-pretreated samples, immediate bond strength values were similar among groups with the exception of PLP, yielding lower dentin bond strength compared with other groups (p<0.05). In aged CHX-pretreated groups, results were similar as with their in vitro counterparts (Table 5).
Figures 1 through 4 demonstrate representative scanning electron micrographs of the resin-infiltrated zone. Regardless of the type of adhesive, testing condition (ie, in vivo/in vitro), or CHX pretreatment, all specimens showed a well-defined, continuous hybrid layer that slightly varied in thickness along the resin-dentin interface.



Citation: Operative Dentistry 41, 3; 10.2341/14-231-C



Citation: Operative Dentistry 41, 3; 10.2341/14-231-C



Citation: Operative Dentistry 41, 3; 10.2341/14-231-C



Citation: Operative Dentistry 41, 3; 10.2341/14-231-C
DISCUSSION
While many studies have investigated the effects of CHX pretreatment on dentin bond strength, controversy still exists regarding whether CHX decreases immediate bond strength.12,16,19,21-24 In the present study, CHX treatment caused lower immediate dentin bond strength values in all test groups. In line with the present results, Campos and others22 observed that 2% CHX caused a decrease in immediate dentin bond strength values of self-etch adhesives, Clearfil SE Bond, and Clearfil S3 Bond. In the same study, however, CHX application had no influence on the immediate bond strength values of the tested etch-and-rinse adhesives. Other studies utilizing different self-etch or etch-and rinse adhesives have reported that CHX has no effect on immediate bond strength values.12,19,23-26 In another study, CHX was found to preserve the bonding durability of an etch-and-rinse adhesive (Single Bond) but was unable to maintain a stable bond of a one-step self-etch adhesive system (GBond).27 Because CHX generally inhibits MMPs without impairing dentin bond strength,28 the benefits of CHX pretreatment might be expected over the course of time. Manfro and others21 demonstrated the effectiveness of CHX in preventing the degradation of the adhesive interface in primary dentin. In their study, they found no significant reduction in dentin bond strength in aged samples, while in the absence of CHX treatment, significant reductions were observed. The present results corroborate with those of previous studies reporting that CHX application has no adverse effect on aged dentin bond strength values. Further, the present study demonstrates that CHX treatment leads to higher aged dentin bond strength compared with non-CHX-treated groups. Therefore, the first null hypothesis should be rejected. It has been proposed that the use of 2% chlorhexidine before application of adhesive resins reduces the deterioration of hybrid layers following exposure to water.29 In the present study, the higher bond strength values obtained in aged CHX-treated samples might be related with the inhibition effect of CHX on MMPs that had been activated by the acidity of the tested adhesives. As known, mild acids have a potential to activate MMPs, and particularly, pH values ranging from 2.3 to 5 are effective in activating gelatinases.30 The self-etch adhesive used in this study has a pH value of 2.4 and is, thus, capable of enhancing dentin proteolytic activity without denaturation of the enzymes. The observation of increased aged bond strength after CHX pretreatment has been demonstrated previously, utilizing an etch-and-rinse and a self-etch adhesive.31
For the experimental groups that did not receive CHX-pretreatment, our results confirm previous studies that reported reductions in the dentin bond strength of different self-etch and etch-and-rinse adhesives after aging.32-37 For CHX-pretreated groups, however, establishing correlations between the present results and those of previous reports might be more complicated. It has been shown that CHX has no significant effect on bond strength stability, and that there was a decrease in bond strength over a six-month period of water storage.37 Further, in an 18-month clinical study comparing the performance of an etch-and-rinse and self-etch adhesives in noncarious cervical lesions with and without CHX pretreatment,38 the authors concluded that CHX did not influence the performance of the tested adhesives. Undoubtedly, clinical retention is affected by many other factors, but those results should be considered when drawing conclusions.
Although clinical trials remain the ultimate instrument, preclinical screenings of materials are still important. However, it is still not fully understood whether there is a relationship between laboratory data and clinical outcomes and also whether the clinical performance is predictable in the lab. To date, only a few studies have compared the behavior of dental biomaterials under both clinical and laboratory conditions.11,37,39-41 The present results indicated differences in the bond strength values of CHX-pretreated groups, with higher bond strength values obtained in in vitro test results. This can be expected , particularly due to the insufficient simulation of oral conditions with thermocycling. Thermocycling is a common procedure to predict how a material would perform over time clinically. Although it is one of the most popular artificial aging methods, there is no evidence to indicate that thermocycling would create specimens equivalent to those fabricated in vivo. Patient-related factors constitute the difference between the laboratory and the clinical study. Comparing the bonding effectiveness of the etch-and-rinse adhesive to the two-step self-etch adhesive, it is evident that both adhesives bonded similarly under in vivo and in vitro conditions in non-CHX treated samples. Immediate bond strength values of one-step and all-in-one self-etch adhesives, Clearfil S3 Bond and Adper Prompt-L-Pop, were also similar. Therefore, the second null hypothesis should be partly accepted.
In the present study, the bond strength values of Adper Single Bond and Clearfil SE Bond were significantly higher than the tested one-step self-etch adhesives. Several studies have shown that etch-and-rinse adhesives yield bonding values superior to those of one-step self-etch adhesives. Perdigao and others42 demonstrated that Adper Single Bond and Clearfil SE Bond showed similar bonding values that were also higher than one-step self-etch adhesives. Indeed, in several studies, Adper Single Bond and Clearfil SE Bond have shown significantly higher bond strength values compared with other different adhesives.34,43 The ethanol and HEMA content of Single Bond enables high wettability, whereas 10-MDP in Clearfil SE Bond binds to calcium salts that maintain a stable bonding interface.34 Further, the relatively higher concentration of camphorquinone in Clearfil SE Bond improves its polymerization rate.44
In the present study, the lowest bond strength values were obtained in aged one-step self-etch adhesives. Presumably, such levels of bond strength may result from the high acidity of these adhesives that degrades the collagen matrix stabilization.45 It may be possible to speculate that additional factors, not possible to show with the present methodology, such as resin monomers with low conversion rate44 and occurrence of water trees,34,45 may have contributed to these results. As bond strength values differ according to the tested adhesive systems, the third null hypothesis should also be rejected.
Adhesive and mixed failure types have been observed in a majority of microtensile bond strength studies, irrespective of CHX pretreatment.20-22,31,34 Osorio and others34 reported that while mixed failure types were observed after immediate bond strength testing, adhesive failures were prominent in aged groups subjected to debonding forces. In the present study, predominance of adhesive/mixed failure was observed in all groups with a lack of statistical significance. In resin-dentin interface evaluation by SEM, the hybrid layer was found to be intact and mostly continuous in all tested samples.
Additional long-term studies might be necessary to determine the long-term effects of CHX on the bond strengths of different adhesive systems.
CONCLUSIONS
Within the limitations of this study, the following conclusions were drawn:
- 1)
The immediate bond strength values of all tested adhesives were significantly higher than “aged” ones.
- 2)
The application of CHX caused lower immediate and higher aged bond strength values.

SEM images of composite-dentin interface with Adper Single Bond 2. (A): Immediate and CHX (+). (B): Immediate and CHX (−). (C): Aged and CHX (+). (D): Aged and CHX (−).

SEM images of composite-dentin interface with Clearfil SE Bond. (A): Immediate and CHX (+). (B): Immediate and CHX (−). (C): Aged and CHX (+). (D): Aged and CHX (−).

SEM images of composite-dentin interface with Clearfil S3. (A): Immediate and CHX (+). (B): Immediate and CHX (−). (C): Aged and CHX (+). (D) Aged and CHX (−).

SEM images of composite-dentin interface with Prompt-L-Pop. (A): Immediate and CHX (+). (B): Immediate and CHX (−). (C): Aged and CHX (+). (D): Aged and CHX (−).
Contributor Notes
Ayse Rüya Yazici, DDS, PhD, Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey