Editorial Type:
Article Category: Research Article
 | 
Online Publication Date: 01 Jul 2018

Nanofilled Resin Composite Properties and Clinical Performance: A Review

,
,
, and
Page Range: E173 – E190
DOI: 10.2341/17-208-T
Save
Download PDF

SUMMARY

The aim of this review was to compile recent evidence related to nanofilled resin composite materials regarding the properties and clinical performance. Special attention was given to mechanical properties, such as strength, hardness, abrasive wear, water sorption, and solubility. The clinical performance of nanocomposite materials compared with hybrid resin composites was also addressed in terms of retention and success rates, marginal adaptation, color match, and surface roughness. A search of English peer-reviewed dental literature (2003-2017) from PubMed and MEDLINE databases was conducted using the terms “nanocomposites” or “nanofilled resin composite” and “clinical evaluation.” The list was screened, and 82 papers that were relevant to the objectives of this work were included in the review. Mechanical properties of nanocomposites are generally comparable to those of hybrid composites but higher than microfilled composites. Nanocomposites presented lower abrasive wear than hybrids but higher sorption values. Their clinical performance was comparable to that of hybrid composites.

INTRODUCTION

Resin composite materials are increasingly used in modern dentistry due to several desirable qualities, such as esthetic appearance and good physical and mechanical properties.1 The availability of numerous commercial products makes resin composite suitable for use in several clinical applications, including as restorative materials, cavity liners, core buildups, and luting cements, to name a few.2-4 Previous research has addressed several shortcomings of composites, such as polymerization shrinkage, strength, and wear resistance.5-9 A wide range of resin composites is available for anterior and posterior restorations. This implies a wide range of organic and inorganic constituents that will influence their clinical handling and performance.1 The main composition of resin composites consists of an organic polymeric matrix, inorganic fillers, and a silane coupling agent that links the first two components together.10 Mechanical properties and esthetic appearance of resin composites have been shown to be influenced by their composition and microstructure.11,12 Despite the improvements in various properties over recent years, major changes to their composition have involved mainly the fillers rather than the monomer systems, which were originally developed by Bowen13 in 1962.

The original resin matrix monomer system was based on the formula presented by Foster and Walker14 consisting mainly of (Bis-GMA: 2,2-bis[4-(2-hydroxy-3-methacryloxypropoxy) phenyl] propane) and later urethane dimethacrylate. Several approaches were suggested to modify the monomer component to create resin composites with no or minimal shrinkage on polymerization and improved wear resistance. One of the modifications in the monomer system was the use of ring opening monomers. These monomers resulted in the development of resin composites with decreased polymerization shrinkage (ie, silorane-based resin composites).15 Organically modified ceramics (ormocers) were introduced to overcome problems of polymerization shrinkage associated with conventional methacrylate-based resin composites. Ormocers contain inorganic-organic copolymers in addition to inorganic filler particles.16 Ormocers have shown lower wear rates compared to other composites17 and similar shrinkage to hybrid composites despite their lower filler content.18

It is well documented that mechanical properties of resin composites are significantly influenced by the filler particle morphology (shape), size range, and volume content.11,19,20 The increasing demand for esthetic dentistry has led to the development of resin composites used for direct restorations. These composites have demonstrated improved clinical performance both physically and esthetically.21 Traditional composites have been classified based on filler size. The classification divided the composites into macrofilled, microfilled, hybrid, and microhybrid materials. The introduction of nanometer-sized particles has been one of the latest developments in the field and is thought to offer superior esthetics and polishability in addition to excellent wear resistance and strength.21,22

In his review of resin composites, Ferracane2 described the chronological development of resin composites outlining their classification according to the filler particle size as follows: macrofill (10 to 50 μm), microfill (40 to 50 nm), and hybrid (10 to 50 μm+40 nm). Hybrid composites were further distinguished as “midifill resin composites” with an average particle size slightly greater than 1 μm and a portion of the 40 nm fillers. Further refinement of the filler particles resulted in what is known as microhybrids (0.6 to 1 μm and 40 nm). Finally, nanofilled resin composites (1 to 100 nm) and nanohybrid that is a combination of microhybrid and nanofilled-size particles were introduced.

The growing interest in nanotechnology and its use in resin composites was based on the desire to utilize the ability of nanosized particles to alter the structure of the composite. This in turn may improve mechanical, chemical, and optical properties and develop a resin composite that can perform optimally in all parts of the mouth.22,23 Consequently, Mitra and others22 introduced novel nanofillers and then utilized various methacrylate resins and curing technologies to develop nanocomposites. This nanocomposite was subsequently marketed as the Filtek range of restorative materials (3M ESPE, St Paul, MN, USA).

Two classes of resin composites that include nanoscale filler particles in their composition have been introduced, namely, nanofilled and nanohybrid resin composites. While nanofilled composites use nanosized particles throughout the resin matrix,22 nanohybrids include a mixture of nanosized and conventional filler particles.24 It has been previously suggested that the size of the fillers observed for the nanohybrid composites could be a reason to not refer to them as nanostructured materials. This suggestion was based on the fact that microhybrid composites may contain a mixture of similar nanosized particles in combination with larger filler particles.1 Nanosized fillers can be categorized as either isolated discrete particles, with dimensions of around 5 to 100 nm, or fused aggregates of primary nanoparticles, where the cluster size may exceed 100 nm.25 It has been proposed that finer particles when incorporated into resin composite will lead to less interparticle space, which will provide more protection to the more vulnerable, softer resin matrix. This in turn will result in reduced “plucking” of filler particles from the material surface.26,27

Previous research has focused on testing various properties of resin composites to evaluate their performance in both laboratory and clinical studies. A large number of these studies aimed at comparing nanocomposites with hybrid and microfilled resin composites.28 Therefore, the objective of the present work was to review laboratory studies that were undertaken on the so-called nanocomposites to examine strength, fracture toughness, surface hardness, abrasive wear, water sorption, and solubility. In addition, a review of the clinical performance of dental nanocomposites was undertaken. Three major categories of resin composites, namely, nanocomposites, hybrid, and microfilled composites, were compared for the sake of offering a clear distinction between their performance and properties. A search of English peer-reviewed literature (2003-2017) from PubMed and MEDLINE databases was conducted using the terms “nanocomposites” or “nanofilled resin composite” and “clinical evaluation.” The list was screened, and 82 papers that were relevant to the objectives of this work were included.

STRENGTH

The main aim of incorporating nanofillers into resin composites (ie, nanocomposites) is to create materials that can be used to restore both anterior and posterior teeth with a high initial polish and gloss. In addition, they should exhibit mechanical strength suitable for use in high-stress-bearing areas.22 Table 1 summarizes the main resin composites mentioned in this literature with their reported classification according to average filler size and the manufacturer.

Table 1 Summary of Resin Composites Reviewed, Category, and Manufacturer Information
Table 1

Flexural Strength

One of the most commonly tested mechanical properties of dental restorative materials is flexural strength (FS), which is considered important for characterizing brittle materials. This type of test generates complex stresses that combine tensile, compressive, and shear stresses when specimens are loaded.29 Several studies examined FS of a number of commercial nanocomposites comparing hybrid and microfilled composites.11,13,22,28-36 Direct comparison showed that the FS of nanocomposites was equivalent to or even higher than other composites tested11,13,22,29,31,37 with values ranging from 103 to 192 MPa.38-40 Mitra and others,22 who developed nanocomposite materials in 2003, reported FS values ranging from 153 to 177 MPa. These values were significantly higher than a number of tested hybrid composites, comparable to that of one hybrid material and significantly higher than the microfilled composite (Table 2). Similarly, Pontes and others29 reported significantly higher FS of a nanocomposite compared with a hybrid. On the other hand, several investigators reported FS values of several nanocomposites comparable to or significantly lower than a number of hybrid materials but significantly higher than microfilled composites.11,31,36,40-42

Table 2 Flexural Strength (FS, MPa) of Resin Composites (N, Nanocomposite; H, Hybrid; M, Microfilled)
Table 2

A number of studies examined the influence of several factors, such as light polymerization mode, filler content (weight), and degree of conversion (DC) (defined as the percentage of reacted aliphatic C=C bonds from the dimethacrylate monomers present in their polymeric matrices),43 on the FS of nanocomposites. Da Silva and others41 examined the influence of using three different polymerization modes on the FS of a hybrid and a nanocomposite (Table 2). The results showed that the FS of the tested composites was not influenced by varying the light polymerization mode. Furthermore, FS of the hybrid composite was significantly higher than the nanocomposite tested. Similar conclusions were drawn by Pontes and others,29 who reported no significant effect on FS of a nanocomposite when varying polymerization modes. Similarly, Beun and others31 and Rodrigues and others42 reported no significant influence of varying polymerization modes on FS of nanocomposites and hybrid composites tested. Degree of conversion has been shown to influence mechanical properties of resin composites.44 Beun and others31 showed a lower DC when using an LED curing unit for a 10 seconds of curing time compared with a QTH curing unit at a 2-mm depth. The 2-mm thickness is traditionally used and recommended by the ISO standard (4049) for dental resins.45 However, in their study, Beun and others31 reported that FS was not a discriminating factor used to differentiate the tested composites since the nanocomposites showed comparable FS values to the universal hybrids. Similar conclusions were drawn by Rodrigues and others42 regarding the effect of DC on FS. They reported comparable FS values of composites tested that were attributed to the high filler loading of both composites (Table 2).

The influence of filler content on FS of nanocomposites has also been examined comprehensively.11,29,31,40,46,47 Rodrigues Junior and others11 showed that there was a positive correlation between the filler weight (FW) and FS of a nanocomposite (FW 84%). The nanocomposite showed intermediate strength values compared to other hybrid composites (FW 74% to 80%) and microfilled composite (FW 64%). However, it has been reported that the fracture behavior and the structural reliability seem to not be affected in highly filled composites compared with composites with lower filler content, such as microfilled resin composites.42 This is because the volume percent content of the fillers may not be markedly different. A number of investigators indicated that filler content and material category had a significant influence on mechanical properties of resin composites, including nanocomposites.28,39,47-49 Higher strength was associated with spherical filler particles,47 and the highest values of FS were observed at a filler volume of 60%. Lin and others38 also suggested higher FS values being associated with higher filler content when testing FS of several nanocomposites; however, in their study, spherical filler particles were not associated with higher strength values. Contrary to the results reported by Lin and others,38 Pontes and others29 reported no positive correlation between filler content and FS, which could be related to the fact that different products where examined in the two previously mentioned studies. Lawson and Burgess46 attempted to evaluate the influence of nanofiller weight percent on mechanical properties of experimental resin composites. Three experimental nanocomposites were formulated with different weight percent filler loads (25%, 50%, and 65%). There was an increase in the FS of all experimental composites up to 50% weight content of the fillers.

Ilie and Hickel28 reported that large variations exist between resin composites within the same category. Flexural strength values ranging from 82 to 125 MPa were reported among 72 commercial composites tested (nanocomposites, hybrid, packable, microfilled, and flowable composites). Comparable mechanical properties were found among a number of hybrid and nanocomposites that were expectantly higher than the flowable composites that have a lesser amount of fillers.28

In conclusion, it would be difficult to predict the performance of a single material based on its type. It is reasonable to conclude that the reported FS of nanocomposites was not superior to that of most hybrid composites but was significantly higher than microfilled composites. Furthermore, it should be noted here that the previously mentioned studies used filler weight percent rather than filler volume percent when comparing different composites. It has been mentioned previously that percent filler content is perhaps best expressed in terms of volume because the mechanical properties of resin composites are dictated mainly by their filler volume fraction.16

Compressive and Diametral Tensile Strength

Compressive strength (CS) and diametral tensile strength (DTS) have been positively correlated in the literature when routinely testing mechanical properties of restorative materials. In both tests, the samples are subjected to a compressive load along different planes. Subsequently, fractures occur due to a combination of tensile and shear stresses.50,51 Mitra and others22 reported CS and DTS values of nanocomposites to be comparable to or higher than the tested hybrid and microfilled composites. The CS and DTS of nanocomposites have also been studied by several investigators who reported variability among nanocomposites when compared with other composites.1,13,21,22,29,33,40 Several investigators attributed variability and differences in part to the nanofiller content (wt%).21,40

The study by Lu and others13 showed comparable values of CS and DTS of a number of nanocomposites and hybrid composites. Similar trends were observed by de Moraes and others,1 Pontes and others,29 and Lien and Vandewalle.36 This was attributed to the presence of large individual filler particles in all of them (Table 3).1

Table 3 Compressive Strength (CS) and Diametral Tensile Strength (DTS, MPa) of Resin Composites (N, Nanocomposite; H, Hybrid; M, Microfilled)
Table 3

The CS and DTS of a number of nanocomposites were evaluated compared with hybrid, microfilled, flowable, and ormocer-based composites.28 Large variations were observed in the strength values (CS: 103 to 267 MPa; DTS: 32 to 45 MPa). Nanocomposites displayed the highest DTS values and comparable CS values to hybrid composites. It was previously reported that the strongest influence was for the filler volume on the DTS and that the influence of material category was low and influenced mainly the CS.29,52,53 Generally, DTS of nanocomposites is at least as good as that of several hybrid composites and higher than a number of hybrid and packable composites. However, Ilie and Hickel28 reported that having a lower modulus of elasticity makes nanocomposites experience more elastic deformation under functional stresses. Therefore, their clinical success is questionable when used in stress-bearing areas.

Fracture Toughness

Fracture toughness (FT) has been occasionally assessed for nanocomposites in addition to the previously mentioned properties.22,33,36,54,55 FT is used for assessing brittle materials in order to identify a material's resistance to fracture. It is also used to assess the amount of energy that is needed to cause the propagation of a crack from a well-defined preexisting crack or notch placed in the tested material.54 However, due to the sensitivity of the test to the dimensions of the prepared notch or flaw, the results can vary among studies.54 Mitra and others22 developed nanocomposites and compared the seven-day FT with hybrid and microfilled composites. The reported values of the two nanocomposites (standard and translucent) were 1.3 and 1.2 MPa√m, respectively, comparable to the hybrid (1.2 MPa√m) and significantly higher than the microfilled (0.9 MPa√m). However, FT of the translucent nanocomposite was significantly lower than other hybrids tested (1.4 MPa√m) (Table 4). Similarly Ilie and others54 reported that FT of a nanocomposite (1.46 MPa√m) was significantly higher than microfilled and flowable composites but lower than most hybrid composites. A number of researchers reported that FT of a nanocomposite was comparable to that of several hybrid composites.30,33,55 Improved mechanical properties of nanocomposites have been previously attributed to the incorporation of nanofillers into the resin matrix. This in turn leads to a reduction in interparticle space and therefore protection of the organic matrix. Furthermore, nanofillers can act as points that may slow the initiation of or even stop crack propagation.54 However, the variations in test protocols and sample preparation among studies may lead to different reported values, making direct comparisons difficult. Generally, the previously mentioned studies indicate that FT of nanocomposites was not superior to that of hybrids but higher than microfilled composites. Further studies using comparable methodology are required to facilitate comparison between materials.

Table 4 Fracture Toughness (FT, MPa√m) of Resin Composites (N, Nanocomposite; H, Hybrid; M, Microfilled)
Table 4

HARDNESS

The hardness of commercial resin composites is a property that is closely related to wear resistance and long-term stability of these materials in the oral environment.56 Surface hardness has also been used as an indicator for the degree of monomer conversion by using the hardness ratio of the bottom and top surfaces of tested samples.57 Previous literature suggests that a composite is “properly” polymerized when the maximum hardness of the bottom surface is ≥80% of the hardness value of the top surface.13,21 The hardness of composites has been positively correlated with filler volume %58 and with filler weight %.21,29,31,46

Various trends have been reported when microhardness of nanocomposites was compared to other types of resin composites (Table 5). Mota and others21 reported a wide range of Knoop microhardness values of nanocomposites that were attributed mainly to differences in the filler content (55 to 123 KHN). Beun and others31 reported significantly higher hardness values of the nanocomposites compared to most of the hybrid and microfilled composites tested in their study. Several researchers reported higher hardness values for a number of nanocomposites compared to hybrid composites. This was attributed to higher filler content, large and densely packed filler particles, and resin content of the nanocomposite tested (Table 5).1,12,29,59 Similarly Lombardini and others57, and Poggio and others60 reported greater surface microhardness of nanocomposites tested compared with the hybrid composites, a finding that was statistically significant (Table 5). The hardness values were not influenced by varying polymerization mode or time or sample thickness, something that was also reported by other researchers.29,61

Table 5 Hardness Values of Resin Composites (N, Nanocomposite; H, Hybrid; M, Microfilled)
Table 5

On the other hand, the microhardness of a nanocomposite was found to be inferior to that of a hybrid by several researchers who attributed this to the complex nature of the nanocomposites' filler content, larger filler volume, and greater amount of pigment. These proposed factors may lead to light attenuation yielding a decreased degree of polymerization (Table 5).36,42,58,62-64 Cao and others65 reported significantly lower Vickers hardness (VH) values of the nanocomposite compared with all tested hybrid composites in their study. Each composite showed a distinct performance in terms of hardness and wear that was attributed to the formulation of each material. Comparable microhardness values were reported by da Silva and others41 for a nanocomposite and a hybrid. However, using high-intensity light yielded the highest microhardness values. A positive correlation between curing method, depth of cure, curing time, and the hardness of nanocomposites were also reported by others.66-68 Similarly, Marchan and others69 reported better microhardness values of tested nanocomposites when light cured for 20 seconds using QTH and LED units compared to 10 seconds. The majority of the nanocomposites produced better VH when cured by LED compared with QTH, the reason for which was unclear. One nanocomposite showed higher VH compared to the other nanocomposites due to its higher filler content (Table 5).

The different values of microhardness reported indicate the influence of the specific formulation of each material, ultimately affecting its hardness behavior.40,65 Moreover, different study protocols and testing methods may account for this variability in reported values. Consequently, it would be difficult to accurately compare results. Therefore, further investigations using comparable methodology should be done in order to be able to directly compare results.

ABRASIVE WEAR

Wear has been defined as the gradual removal of material as a result of the interaction between two surfaces moving against each other.70 Wear of resin composite has been reported to be dependent on filler loading and size in addition to the formulation of its resin matrix and the adhesion of fillers to the matrix.27

Several studies investigated abrasive wear of nanocomposites compared with hybrid and microfilled composites by measuring specimen thickness using calipers,71 assessing surface roughness,12 and measuring weight loss of tested samples following abrasion.30 Table 6 shows abrasive wear values reported by the studies included in the current literature review.

Table 6 Abrasive Wear of Resin Composites (N, Nanocomposite; H, Hybrid; M, Microfilled)
Table 6

Mitra and others22 examined the wear rate of nanocomposites (standard and translucent) compared with hybrid and microfilled composites using a three-body wear test. The wear rate of the standard nanocomposite was equivalent to a hybrid but significantly lower than the other hybrid and microfilled composites. The translucent nanocomposite demonstrated equivalent wear values to the microfilled composite but was significantly lower than the other hybrid materials. Comparable results were shown by Cao and others,65 who reported significantly lower volume loss of the tested nanocomposite compared with hybrid materials. Similarly, Yesil and others72 reported comparable wear rate of a nanocomposite to that of a microfilled and a hybrid composite. Hamouda and Abd Elkader30 reported that the nanocomposite tested in their study demonstrated a significantly lower wear value compared to the hybrid composite that was attributed to the higher filler loading and smaller particle size associated with the nanocomposites. Suzuki and others12 submitted several commercial nanocomposites to an abrasion challenge. It was suggested by the authors that the nanocomposite, which displayed the lowest wear rate, behaves more like a hybrid composite, and its low wear was attributed to its densely packed fillers.73

On the other hand, Mayworm and others74 investigated abrasive wear of a nanocomposite and a hybrid before and after storage in saliva for 62 days. Greater abrasive wear of the nanocomposite compared with a hybrid was reported. This was attributed to the larger interparticle space of the former leading to larger wear rates.

Several researchers have suggested that wear resistance behavior of composites is material dependent and cannot be predicted from only a material's filler loading or organic matrix composition.75 However, the reported results suggest that several commercial nanocomposites have shown wear values that are lower than several hybrid composites. Also, a number of researchers reported comparable wear values between nanocomposites and microfilled composites that have been reported to display the lowest abrasive wear among resin composites.

SORPTION AND SOLUBILITY

Longevity of a restorative material in the oral environment is directly related to its resistance to degradation.76 Therefore, the assessment of solubility and salivary sorption is essential to predict material behavior and clinical performance.32,77 The influence of polymerization mode, curing times, storage media, and filler content on sorption and solubility have also been investigated.1,32,77-79 Table 7 shows reported results from different studies and special testing conditions.

Table 7 Sorption and Solubility Values (μg/mm3) of Resin Composites (N, Nanocomposite; H, Hybrid; M, Microfilled)
Table 7

Da Silva and others77 reported significantly higher sorption and solubility of a nanocomposite compared with a hybrid composite tested in their study when using two polymerization modes (conventional and ramped) (Table 7). The ramped polymerization mode was associated with a lower DC in both composites. Higher sorption and solubility of the nanocomposite was explained by the greater surface area of the nanofillers. This makes them more prone to ion leaching and hydrolysis of the silane coupling agent, leading to the filler particles becoming detached and lost. Higher values of salivary sorption of the nanocomposite were attributed to water accumulation at the filler–matrix interface and inside the aggregates of the nanocomposite. Similarly, Kumar and Sangi32 reported significantly higher water sorption and solubility for one nanocomposite compared with the other nanocomposite and a hybrid following 13 weeks of water storage. Furthermore, lower strength values were reported for the nanocomposite that showed the highest sorption and solubility values. The lower strength values of the nanocomposite were attributed to the poor silane penetration of the porous nanoclusters. This made the nanocomposite susceptible to degradation when stored in water. Lower sorption by the hybrid was attributed to the better coupling between filler content and matrix.80 On the other hand, Lopes and others81 demonstrated no influence of varying polymerization mode on sorption and solubility of a nanocomposite. This was attributed to the formation of a densely cross-linked polymer network due to the use of an adequate energy density in all the curing methods used. Similarly, Shin and others82 reported no effect on sorption values of the tested composites when varying polymerization mode. One nanocomposite displayed the lowest sorption and second-lowest solubility compared to a hybrid composite. This was attributed to its high and dense filler content. Similarly, de Moraes and others1 reported significantly lower sorption of a nanocomposite compared to a hybrid and other nanocomposites tested, while all tested composites displayed comparable solubility values. The authors suggest that results of water sorption and solubility are probably related to the nature of the organic matrix chemical rather than to the filler content of the material (Table 7).

The effect of using different storage media on sorption and solubility of resin composites was assessed by several researchers.78,81,83 Almeida and others78 and Lopes and others81 demonstrated an influence of storage media on the sorption of resin composites tested. Negative values of solubility were reported by researchers for a number of nanocomposites indicating weight gain masking the real solubility. Almeida and others78 reported significantly higher sorption of a nanocomposite compared with a hybrid in Listerine (Warner Lambert Health Care, Eastleigh, UK), Plax fresh (Colgate-Palmolive, Guilford, UK), Plax (Colgate-Palmolive), and artificial saliva. The solubility of the nanocomposite and hybrid composites was comparable, with significantly higher values obtained when placed in Listerine and Plax fresh. Similar results regarding water sorption were shown by Curtis and others,84 who investigated these properties after different storage periods of a nanocomposite and hybrid composite. It was suggested that the higher water sorption was related to the larger ratio of surface area to volume of the silica nanofillers and the hydrophilic nature of the polymeric matrix.85

Goncalves and others79 assessed sorption and solubility of a nanocomposite and a hybrid and DC in simulated deep proximal cavities. This was done to investigate composite behavior in a situation similar to a clinical setting. Sorption and solubility were assessed for every 1-mm increment of the 5-mm-deep restoration in three immersion media: distilled water, artificial saliva, and lactic acid. The nanocomposite displayed a lower DC and significantly higher sorption and solubility values than the hybrid. Regardless of media type, the immersion of both resin composites presented an increase in solubility and sorption as a function of depth.

The previously mentioned data generally indicate higher sorption and solubility of nanocomposites. The number of studies investigating sorption and solubility of nanocomposites compared to hybrid and microfilled composites is still limited. Further investigations using test conditions that simulate a clinical setting and compare a wide range of materials are recommended to ascertain the performance of nanocomposites.

CLINICAL STUDIES

The clinical performance of nanocomposites has been investigated in numerous studies and was found to be comparable to that of other resin composites. The majority of these clinical trials used the modified USPHS criteria first described by Cvar and Ryge86 and the US Public Health Service's modified Ryge criteria.87 These criteria include retention, color match, marginal discoloration, anatomic form, recurrent caries, surface roughness, marginal adaptation, postoperative sensitivity, gross fracture, tooth integrity, gingival health, and proximal contact.

Several clinical studies extending from one to four years reported comparable performance between nanocomposites and hybrid composites in posterior teeth and noncarious cervical cavities.88-102 There was no detection of restoration failure, good surface characteristics, good color match, and no postoperative sensitivity.103-106 Better polishability and surface gloss retention in favor of the nanocomposites were reported and attributed to the reduced filler plucking and less wear of the nanofillers.107-109 However, a number of studies reported a certain degree of deterioration in marginal quality over time with minor defects creating surface roughness in all composites tested.93,109,110 Türkün and others111 reported a high retention rate of the nanocomposite but a better color match of the polyacid-modified composite tested after two years. In a two-year evaluation, it was reported that beyond one year, a negative step occurred due to wear, in addition to staining of the composites tested.94 Similarly, Dukic and others102 reported deterioration of all composites tested after three years with regard to anatomic form, marginal integrity, and marginal discoloration, but these composites were still regarded as being clinically acceptable.

Several long-term clinical performance studies of nanocomposites ranging from five to 10 years have been published. Palaniappane and others112,113 evaluated the five-year clinical performance of nanocomposite materials compared to hybrid composites in occlusal and posterior approximal cavities. There was no significant difference in the vertical and volumetric wear between one nanocomposite and a hybrid composite as reported by Palaniappane and others,112 while another nanocomposite material showed lower volume loss compared to the hybrid composites tested by Palaniappane and others113 after five years. This was explained by the densely packed nanofillers in the nanocomposite that offered protection to the softer resin matrix from the abrasive action of food particles.

Cetin and others115 reported excellent five-year clinical performance of two nanocomposites when compared to two indirect composite materials. No restorations were rated unacceptable in any aspect of the evaluation. A nanocomposite was also compared to a hybrid material after six, eight, and 10 years.116,117 The overall success rates of the nanocomposite were 88.1%, 98%, and 80%, respectively, with a comparable performance between the investigated composites.116-118 The higher success rate at eight years compared with six years may be due to the use of different nanocomposite material in each study. Furthermore, the inclusion criteria for recruited subjects differed in that high-caries-risk patients were not excluded from the six-year evaluation period study.116 On the other hand, Frankenberger and others118 included subjects with a high level of oral hygiene, which may have contributed to the reported higher success rate after eight years compared with six years. The authors reported no significant difference in the clinical behavior between the tested composite restorations. Furthermore, significant changes over time were found for all criteria evaluated.

On the basis of the results of the previous studies, it seems reasonable to conclude that there is no evidence yet that the nanocomposites perform clinically better than hybrid composites.

CONCLUSION

The current review of the published literature has shown that commercially available nanocomposite materials do not hold any significant advantage over hybrid composites in terms of strength and hardness. Furthermore, higher sorption and solubility values were found for nanocomposites compared with hybrid composites, and these might influence their clinical performance. On the other hand, the incorporation of nanofillers into resin composite materials was associated with lower abrasive wear of nanocomposites. However, attention should be focused on the resin matrix composition and not only the filler system to be able to assess abrasive wear behavior. In the current review, nanocomposites demonstrated acceptable clinical performance compared with hybrid resin composites for review periods ranging from one to 10 years. However, there was no definitive report of the superior performance of nanocomposites in the majority of evaluation criteria used.

Conflict of Interest

The authors of this article certify that they have no proprietary, financial, or other personal interest of any nature or kind in any product, service, and/or company that is presented in this article.

REFERENCES

  • 1
    de Moraes RR,
    Goncalves Lde S,
    Lancellotti AC,
    Consani S,
    Correr-Sobrinho L,
    &
    Sinhoreti MA
    (2009) Nanohybrid resin composites: Nanofiller loaded materials or traditional microhybrid resins?Operative Dentistry34(
    5
    )551-557.
  • 2
    Ferracane JL
    (2011) Resin composite—State of the artDental Materials27(
    1
    )29-38.
  • 3
    Curtis AR,
    Palin WM,
    Fleming GJ,
    Shortall AC,
    &
    Marquis PM
    (2009) The mechanical properties of nanofilled resin-based composites: The impact of dry and wet cyclic pre-loading on bi-axial flexure strengthDental Materials25(
    2
    )188-197.
  • 4
    Lu H,
    Roeder LB,
    Lei L,
    &
    Powers JM
    (2005) Effect of surface roughness on stain resistance of dental resin compositesJournal of Esthetic and Restorative Dentistry17(
    2
    )102-108;discussion 109.
  • 5
    Drummond JL
    (2008) Degradation, fatigue, and failure of resin dental composite materialsJournal of Dental Research87(
    8
    )710-719.
  • 6
    Ferracane JL,
    &
    Mitchem JC
    (1994) Properties of posterior composite: Results of round robin testing for a specificationDental Materials10(
    2
    )92-99.
  • 7
    Lu H,
    Stansbury JW,
    &
    Bowman CN
    (2005) Impact of curing protocol on conversion and shrinkage stressJournal of Dental Research84(
    9
    )822-826.
  • 8
    Tyas MJ
    (1990) Correlation between fracture properties and clinical performance of composite resins in Class IV cavitiesAustralian Dental Journal35(
    1
    )46-49.
  • 9
    Watts DC,
    Marouf AS,
    &
    Al-Hindi AM
    (2003) Photo-polymerization shrinkage-stress kinetics in resin-composites: Methods developmentDental Materials19(
    1
    )1-11.
  • 10
    Rawls HR,
    &
    Esquivel-Upshaw JF
    (2003) Restorative resinsIn:
    Anusavice KJ
    (ed)Phillips' Science of Dental Materials
    Elsevier Science
    ,
    St Louis, MO
    399-437.
  • 11
    Rodrigues Junior SA,
    Zanchi CH,
    Carvalho RV,
    &
    Demarco FF
    (2007) Flexural strength and modulus of elasticity of different types of resin-based compositesBrazilian Oral Research21(
    1
    )16-21.
  • 12
    Suzuki T,
    Kyoizumi H,
    Finger WJ,
    Kanehira M,
    Endo T,
    Utterodt A,
    Hisamitsu H,
    &
    Komatsu M
    (2009) Resistance of nanofill and nanohybrid resin composites to toothbrush abrasion with calcium carbonate slurryDental Materials Journal28(
    6
    )708-716.
  • 13
    Lu H,
    Lee YK,
    Oguri M,
    &
    Powers JM
    (2006) Properties of a dental resin composite with a spherical inorganic fillerOperative Dentistry31(
    6
    )734-740.
  • 14
    Foster J,
    &
    Walker R
    (1674) US Patent No. 3825518.
  • 15
    Maghaireh GA,
    Taha NA,
    &
    Alzraikat H
    (2017) The silorane-based resin composites: A reviewOperative Dentistry42(
    1
    )E24-E34.
  • 16
    Ilie N,
    &
    Hickel R
    (2011) Resin composite restorative materialsAustralian Dental Journal56(
    Supplement 1
    )59-66.
  • 17
    Tagtekin DA,
    Yanikoglu FC,
    Bozkurt FO,
    Kologlu B,
    &
    Sur H
    (2004) Selected characteristics of an ormocer and a conventional hybrid resin compositeDental Materials20(
    5
    )487-497.
  • 18
    Cattani-Lorente M,
    Bouillaguet S,
    Godin CH,
    &
    Meyer JM
    (2001) Polymerization shrinkage of ormocer based dental restorative composites. European Cells and Materials1(
    Supplement 1
    )25-26.
  • 19
    Kim KH,
    Ong JL,
    &
    Okuno O
    (2002) The effect of filler loading and morphology on the mechanical properties of contemporary compositesJournal of Prosthetic Dentistry87(
    6
    )642-649.
  • 20
    Randolph LD,
    Palin WM,
    Leloup G,
    &
    Leprince JG
    (2016) Filler characteristics of modern dental resin composites and their influence on physico-mechanical propertiesDental Materials32(
    12
    )1586-1599.
  • 21
    Mota EG,
    Oshima HM,
    Burnett LH Jr,
    Pires LA,
    &
    Rosa RS
    (2006) Evaluation of diametral tensile strength and Knoop microhardness of five nanofilled composites in dentin and enamel shadesStomatologija8(
    3
    )67-69.
  • 22
    Mitra SB,
    Wu D,
    &
    Holmes BN
    (2003) An application of nanotechnology in advanced dental materialsJournal of the American Dental Association134(
    10
    )1382-1390.
  • 23
    Craig RG
    (2006) Resin composite restorative materialsIn:
    Powers JM,
    Sakaguchi RL
    (eds)Craig's Restorative Dental Materials
    Elsevier
    ,
    St Louis, MO
    189-207.
  • 24
    Swift EJ
    (2005) NanocompositesJournal of Esthetic and Restorative Dentistry17(
    1
    )3-4.
  • 25
    Cramer NB,
    Stansbury JW,
    &
    Bowman CN
    (2011) Recent advances and developments in composite dental restorative materialsJournal of Dental Research90(
    4
    )402-416.
  • 26
    Moraes RR,
    Ribeiro Ddos S,
    Klumb MM,
    Brandt WC,
    Correr-Sobrinho L,
    &
    Bueno M
    (2008) In vitro toothbrushing abrasion of dental resin composites: Packable, microhybrid, nanohybrid and microfilled materialsBrazilian Oral Research22(
    2
    )112-118.
  • 27
    Turssi CP,
    De Moraes Purquerio B,
    &
    Serra MC
    (2003) Wear of dental resin composites: Insights into underlying processes and assessment methods—A reviewJournal of Biomedical Materials Research Part B: Applied Biomaterials65(
    2
    )280-285.
  • 28
    Ilie N,
    &
    Hickel R
    (2009) Investigations on mechanical behaviour of dental compositesClinical Oral Investigations13(
    4
    )427-438.
  • 29
    Pontes LF,
    Alves EB,
    Alves BP,
    Ballester RY,
    Dias CG,
    &
    Silva CM
    (2013) Mechanical properties of nanofilled and microhybrid composites cured by different light polymerization modesGeneral Dentistry61(
    3
    )30-33.
  • 30
    Hamouda IM,
    &
    Abd Elkader H
    (2012) Evaluation the mechanical properties of nanofilled composite resin restorative materialJournal of Biomaterials and Nanobiotechnology3(
    2
    )238-242.
  • 31
    Beun S,
    Glorieux T,
    Devaux J,
    Vreven J,
    &
    Leloup G
    (2007) Characterization of nanofilled compared to universal and microfilled compositesDental Materials23(
    1
    )51-59.
  • 32
    Kumar N,
    &
    Sangi L
    (2014) Water sorption, solubility, and resultant change in strength among three resin-based dental compositesJournal of Investigative and Clinical Dentistry5(
    2
    )144-150.
  • 33
    Takahashi H,
    Finger WJ,
    Endo T,
    Kanehira M,
    Koottathape N,
    Komatsu M,
    &
    Balkenhol M
    (2011) Comparative evaluation of mechanical characteristics of nanofiller containing resin compositesAmerican Journal of Dentistry24(
    5
    )264-270.
  • 34
    Ilie N,
    Bauer H,
    Draenert M,
    &
    Hickel R
    (2013) Resin-based composite light-cured properties assessed by laboratory standards and simulated clinical conditionsOperative Dentistry38(
    2
    )159-167.
  • 35
    Ilie N,
    Rencz A,
    &
    Hickel R
    (2013) Investigations towards nano-hybrid resin-based compositesClinical Oral Investigations17(
    1
    )185-193.
  • 36
    Lien W,
    &
    Vandewalle KS
    (2010) Physical properties of a new silorane-based restorative systemDental Materials26(
    4
    )337-344.
  • 37
    Rodrigues SA Jr,
    Ferracane JL,
    &
    Della Bona A
    (2008) Flexural strength and Weibull analysis of a microhybrid and a nanofill composite evaluated by 3- and 4-point bending testsDental Materials24(
    3
    )426-431.
  • 38
    Lin J,
    Sun M,
    Zheng Z,
    Shinya A,
    Han J,
    Lin H,
    &
    Zheng G
    (2013) Effects of rotating fatigue on the mechanical properties of microhybrid and nanofiller-containing compositesDental Materials Journal32(
    3
    )476-483.
  • 39
    Sideridou ID,
    Karabela MM,
    &
    Vouvoudi E
    (2011) Physical properties of current dental nanohybrid and nanofill light-cured resin compositesDental Materials27(
    6
    )598-607.
  • 40
    Rosa RS,
    Balbinot CE,
    Blando E,
    Mota EG,
    Oshima HM,
    Hirakata L,
    Pires LA,
    &
    Hubler R
    (2012) Evaluation of mechanical properties on three nanofilled compositesStomatologija14(
    4
    )126-130.
  • 41
    da Silva EM,
    Poskus LT,
    &
    Guimaraes JG
    (2008) Influence of light-polymerization modes on the degree of conversion and mechanical properties of resin composites: A comparative analysis between a hybrid and a nanofilled compositeOperative Dentistry33(
    3
    )287-293.
  • 42
    Rodrigues SA Jr,
    Scherrer SS,
    Ferracane JL,
    &
    Della Bona A
    (2008) Microstructural characterization and fracture behavior of a microhybrid and a nanofill compositeDental Materials24(
    9
    )1281-1288.
  • 43
    Ferracane JL
    (1985) Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resinsDental Materials1(
    1
    )11-14.
  • 44
    Ferracane JL,
    Berge HX,
    &
    Condon JR
    (1998) In vitro aging of dental composites in water—Effect of degree of conversion, filler volume, and filler/matrix couplingJournal of Biomedical Materials Research42(
    3
    )465-472.
  • 45
    Standard I
    (2000) ISO 4049 Polymer based filling, restorative and luting materials.
    Geneve
    :
    International Organization for Standardization 3rd edition 1-27
    .
  • 46
    Lawson NC,
    &
    Burgess JO
    (2015) Wear of nanofilled dental composites at varying filler concentrationsJournal of Biomedical Materials Research Part B: Applied Biomaterials103(
    2
    )424-429.
  • 47
    Melander J,
    Dunn WP,
    Link MP,
    Wang Y,
    Xu C,
    &
    Walker MP
    (2011) Comparison of flexural properties and surface roughness of nanohybrid and microhybrid dental compositesGeneral Dentistry59(
    5
    )342-347;quiz 348-349.
  • 48
    Braem M,
    Lambrechts P,
    Van Doren V,
    &
    Vanherle G
    (1986) The impact of composite structure on its elastic responseJournal of Dental Research65(
    5
    )648-653.
  • 49
    Ikejima I,
    Nomoto R,
    &
    McCabe JF
    (2003) Shear punch strength and flexural strength of model composites with varying filler volume fraction, particle size and silanationDental Materials19(
    3
    )206-211.
  • 50
    Anusavice KJ
    (2003) Mechanical properties of dental materialsIn:
    Anusavice KJ
    (ed)Phillips' Science of Dental Materials
    Elsevier Science
    ,
    St Louis, MO
    73-100.
  • 51
    Della Bona A,
    Benetti P,
    Borba M,
    &
    Cecchetti D
    (2008) Flexural and diametral tensile strength of composite resinsBrazilian Oral Research22(
    1
    )84-89.
  • 52
    Gogna R,
    Jagadis S,
    &
    Shashikal K
    (2011) A comparative in vitro study of microleakage by a radioactive isotope and compressive strength of three nanofilled composite resin restorationsJournal of Conservative Dentistry14(
    2
    )128-131.
  • 53
    Hegde MN,
    Hegde P,
    Bhandary S,
    &
    Deepika K
    (2011) An evalution of compressive strength of newer nanocomposite: An in vitro studyJournal of Conservative Dentistry14(
    1
    )36-39.
  • 54
    Ilie N,
    Hickel R,
    Valceanu AS,
    &
    Huth KC
    (2012) Fracture toughness of dental restorative materialsClinical Oral Investigations16(
    2
    )489-498.
  • 55
    Thomaidis S,
    Kakaboura A,
    Mueller WD,
    &
    Zinelis S
    (2013) Mechanical properties of contemporary composite resins and their interrelationsDental Materials29(
    8
    )e132-e141.
  • 56
    Yoldas O,
    Akova T,
    &
    Uysal H
    (2004) Influence of different indentation load and dwell time on Knoop microhardness tests for composite materialsPolymer Testing23(
    3
    )343-346.
  • 57
    Lombardini M,
    Chiesa M,
    Scribante A,
    Colombo M,
    &
    Poggio C
    (2012) Influence of polymerization time and depth of cure of resin composites determined by Vickers hardnessDental Research Journal (Isfahan)9(
    6
    )735-740.
  • 58
    Rastelli AN,
    Jacomassi DP,
    Faloni AP,
    Queiroz TP,
    Rojas SS,
    Bernardi MI,
    Bagnato VS,
    &
    Hernandes AC
    (2012) The filler content of the dental composite resins and their influence on different propertiesMicroscopy Research and Technique75(
    6
    )758-765.
  • 59
    Kaminedi RR,
    Penumatsa NV,
    Priya T,
    &
    Baroudi K
    (2014) The influence of finishing/polishing time and cooling system on surface roughness and microhardness of two different types of composite resin restorationsJournal of International Society of Preventive and Community Dentistry4(
    Supplement 2
    )S99-S104.
  • 60
    Poggio C,
    Lombardini M,
    Gaviati S,
    &
    Chiesa M
    (2012) Evaluation of Vickers hardness and depth of cure of six composite resins photo-activated with different polymerization modesJournal of Conservative Dentistry15(
    3
    )237-241.
  • 61
    Groninger AIS,
    Soares GP,
    Sasaki RT,
    Ambrosano GMB,
    &
    Aguira FHB
    (2011) Microhardness of nanofilled composite resin light-cured by LED or QTH units with different timesBrazilian Journal of Oral Sciences10(
    3
    )189-192.
  • 62
    Thome T,
    Steagall W Jr,
    Tachibana A,
    Braga SR,
    &
    Turbino ML
    (2007) Influence of the distance of the curing light source and composite shade on hardness of two compositesJournal of Applied Oral Science15(
    6
    )486-491.
  • 63
    Friedman J,
    &
    Hassan R
    (1984) Comparison study of visible curing lights and hardness of light-cured restorative materialsJournal of Prosthetic Dentistry52(
    4
    )504-506.
  • 64
    Shortall AC,
    Wilson HJ,
    &
    Harrington E
    (1995) Depth of cure of radiation-activated composite restoratives—Influence of shade and opacityJournal of Oral Rehabilitation22(
    5
    )337-342.
  • 65
    Cao L,
    Zhao X,
    Gong X,
    &
    Zhao S
    (2013) An in vitro investigation of wear resistance and hardness of composite resinsInternational Journal of Clinical and Experimental Medicine6(
    6
    )423-430.
  • 66
    Akram S,
    Ali Abidi SY,
    Ahmed S,
    Meo AA,
    &
    Qazi FU
    (2011) Effect of different irradiation times on microhardness and depth of cure of a nanocomposite resinJournal of the College of Physicians and Surgeons Pakistan21(
    7
    )411-414.
  • 67
    Feitosa VP,
    Fugolin AP,
    Correr AB,
    Correr-Sobrinho L,
    Consani S,
    Watson TF,
    Sinhoreti MA,
    &
    Sauro S
    (2012) Effects of different photo-polymerization protocols on resin-dentine muTBS, mechanical properties and cross-link density of a nano-filled resin compositeJournal of Dentistry40(
    10
    )802-809.
  • 68
    da Silva EM,
    Poskus LT,
    Guimaraes JG,
    de Araujo Lima Barcellos A,
    &
    Fellows CE
    (2008) Influence of light polymerization modes on degree of conversion and crosslink density of dental compositesJournal of Materials Science: Materials in Medicine19(
    3
    )1027-1032.
  • 69
    Marchan SM,
    White D,
    Smith WA,
    Raman V,
    Coldero L,
    &
    Dhuru V
    (2011) Effect of reduced exposure times on the microhardness of nanocomposites polymerized by QTH and second-generation LED curing lightsOperative Dentistry36(
    1
    )98-103.
  • 70
    Mair LH,
    Stolarski TA,
    Vowles RW,
    &
    Lloyd CH
    (1996) Wear: Mechanisms, manifestations and measurement. Report of a workshopJournal of Dentistry24(
    1-2
    )141-148.
  • 71
    Teixeira EC,
    Thompson JL,
    Piascik JR,
    &
    Thompson JY
    (2005) In vitro toothbrush-dentifrice abrasion of two restorative compositesJournal of Esthetic and Restorative Dentistry17(
    3
    )172-180;discussion 181-172.
  • 72
    Yesil ZD,
    Alapati S,
    Johnston W,
    &
    Seghi RR
    (2008) Evaluation of the wear resistance of new nanocomposite resin restorative materialsJournal of Prosthetic Dentistry99(
    6
    )435-443.
  • 73
    Schultz S,
    Rosentritt M,
    Behr M,
    &
    Handel G
    (2010) Mechanical properties and three-body wear of dental restoratives and their comparative flowable materialsQuintessence International41(
    1
    )e1-e10.
  • 74
    Mayworm CD,
    Camargo SS Jr,
    &
    Bastian FL
    (2008) Influence of artificial saliva on abrasive wear and microhardness of dental composites filled with nanoparticlesJournal of Dentistry36(
    9
    )703-710.
  • 75
    Han JM,
    Zhang H,
    Choe HS,
    Lin H,
    Zheng G,
    &
    Hong G
    (2014) Abrasive wear and surface roughness of contemporary dental composite resinDental Materials Journal33(
    6
    )725-732.
  • 76
    Christensen GJ
    (2005) Longevity of posterior tooth dental restorationsJournal of the American Dental Association136(
    2
    )201-203.
  • 77
    da Silva EM,
    Almeida GS,
    Poskus LT,
    &
    Guimaraes JG
    (2008) Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofilled resin compositeJournal of Applied Oral Science16(
    2
    )161-166.
  • 78
    Almeida GS,
    Poskus LT,
    Guimaraes JG,
    &
    da Silva EM
    (2010) The effect of mouthrinses on salivary sorption, solubility and surface degradation of a nanofilled and a hybrid resin compositeOperative Dentistry35(
    1
    )105-111.
  • 79
    Goncalves L,
    Amaral CM,
    Poskus LT,
    Guimaraes JG,
    &
    Silva EM
    (2014) Degradation of resin composites in a simulated deep cavityBrazilian Dental Journal25(
    6
    )532-537.
  • 80
    Kalachandra S,
    &
    Wilson TW
    (1992) Water sorption and mechanical properties of light-cured proprietary composite tooth restorative materialsBiomaterials13(
    2
    )105-109.
  • 81
    Lopes LG,
    Jardim Filho Ada V,
    de Souza JB,
    Rabelo D,
    Franco EB,
    &
    de Freitas GC
    (2009) Influence of pulse-delay curing on sorption and solubility of a composite resinJournal of Applied Oral Sience17(
    1
    )27-31.
  • 82
    Shin DH,
    Yun DI,
    Park MG,
    Ko CC,
    Garcia-Godoy F,
    Kim HI,
    &
    Kwon YH
    (2011) Influence of DPSS laser on polymerization shrinkage and mass change of resin compositesPhotomedicine and Laser Surgery29(
    8
    )545-550.
  • 83
    de Azevedo Miranda D,
    dos Santos Bertoldo CE,
    Ambrosano GM,
    Aguiar FH,
    Lima DA,
    &
    Lovadino JR
    (2013) Effect of curing light distance and different mouthwashes on the sorption and solubility of a nanofilled compositeEuropean Journal of Esthetic Dentistry8(
    1
    )88-102.
  • 84
    Curtis AR,
    Shortall AC,
    Marquis PM,
    &
    Palin WM
    (2008) Water uptake and strength characteristics of a nanofilled resin-based compositeJournal of Dentistry36(
    3
    )186-193.
  • 85
    da Silva EM,
    Almeida GS,
    Poskus LT,
    &
    Guimaraes JG
    (2008) Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofilled resin compositeJournal of Applied Oral Sience16(
    2
    )161-166.
  • 86
    Cvar JF,
    &
    Ryge G
    (1971) Criteria for the clinical evaluation of dental restorative materialsUS Public Health Services Publication No. 790-244
    San Francisco, CA
    :
    US Government Printing Office
    .
  • 87
    Ryge G,
    &
    Snyder M
    (1973) Evaluating the clinical quality of restorationsJournal of the American Dental Association87(
    2
    )369-377.
  • 88
    Dresch W,
    Volpato S,
    Gomes JC,
    Ribeiro NR,
    Reis A,
    &
    Loguercio AD
    (2006) Clinical evaluation of a nanofilled composite in posterior teeth: 12-month resultsOperative Dentistry31(
    4
    )409-417.
  • 89
    Efes BG,
    Dorter C,
    &
    Gomec Y
    (2006) Clinical evaluation of an ormocer, a nanofill composite and a hybrid composite at 2 yearsAmerican Journal of Dentistry19(
    4
    )236-240.
  • 90
    Ergucu Z,
    &
    Turkun LS
    (2007) Clinical performance of novel resin composites in posterior teeth: 18-month resultsJournal of Adhesive Dentistry9(
    2
    )209-216.
  • 91
    Mahmoud SH,
    El-Embaby AE,
    &
    AbdAllah AM
    (2014) Clinical performance of ormocer, nanofilled, and nanoceramic resin composites in Class I and Class II restorations: A three-year evaluationOperative Dentistry39(
    1
    )32-42.
  • 92
    Karaman E,
    Yazici AR,
    Ozgunaltay G,
    &
    Dayangac B
    (2012) Clinical evaluation of a nanohybrid and a flowable resin composite in non-carious cervical lesions: 24-month resultsJournal of Adhesive Dentistry14(
    5
    )485-492.
  • 93
    Kramer N,
    Reinelt C,
    Garcia-Godoy F,
    Taschner M,
    Petschelt A,
    &
    Frankenberger R
    (2009) Nanohybrid composite vs. fine hybrid composite in extended class II cavities: Clinical and microscopic results after 2 yearsAmerican Journal of Dentistry22(
    4
    )228-234.
  • 94
    Kramer N,
    Reinelt C,
    Richter G,
    Petschelt A,
    &
    Frankenberger R
    (2009) Nanohybrid vs. fine hybrid composite in Class II cavities: Clinical results and margin analysis after four yearsDental Materials25(
    6
    )750-759.
  • 95
    Preussker S,
    Poschmann M,
    Kensche A,
    Natusch I,
    Koch R,
    Klimm W,
    &
    Hannig C
    (2014) Three-year prospective clinical performance of a one-step self-etch adhesive and a nanofiller hybrid resin composite in Class V lesionsAmerican Journal of Dentistry27(
    2
    )73-78.
  • 96
    Qin W,
    Song Z,
    Ye YY,
    &
    Lin ZM
    (2013) Two-year clinical evaluation of composite resins in non-carious cervical lesionsClinical Oral Investigations17(
    3
    )799-804.
  • 97
    Schirrmeister JF,
    Huber K,
    Hellwig E,
    &
    Hahn P
    (2009) Four-year evaluation of a resin composite including nanofillers in posterior cavitiesJournal of Adhesive Dentistry11(
    5
    )399-404.
  • 98
    Stojanac IL,
    Premovic MT,
    Ramic BD,
    Drobac MR,
    Stojsin IM,
    &
    Petrovic LM
    (2013) Noncarious cervical lesions restored with three different tooth-colored materials: Two-year resultsOperative Dentistry38(
    1
    )12-20.
  • 99
    Yazici AR,
    Celik C,
    Ozgunaltay G,
    &
    Dayangac B
    (2010) The effects of different light-curing units on the clinical performance of nanofilled composite resin restorations in non-carious cervical lesions: 3-year follow-upJournal of Adhesive Dentistry12(
    3
    )231-236.
  • 100
    Cetin AR,
    &
    Unlu N
    (2009) One-year clinical evaluation of direct nanofilled and indirect composite restorations in posterior teethDental Materials Journal28(
    5
    )620-626.
  • 101
    Cetin AR,
    &
    Unlu N
    (2012) Clinical wear rate of direct and indirect posterior composite resin restorationsInternational Journal of Periodontics and Restorative Dentistry32(
    3
    )e87-e94.
  • 102
    Dukic W,
    Dukic OL,
    Milardovic, S
    &
    Delija B
    (2010) Clinical evaluation of indirect composite restorations at baseline and 36 months after placementOperative Dentistry35(
    2
    )156-164.
  • 103
    Mahmoud SH,
    El-Embaby AE,
    AbdAllah AM,
    &
    Hamama HH
    (2008) Two-year clinical evaluation of ormocer, nanohybrid and nanofill composite restorative systems in posterior teethJournal of Adhesive Dentistry10(
    4
    )315-322.
  • 104
    Sadeghi M,
    Lynch CD,
    &
    Shahamat N
    (2010) Eighteen-month clinical evaluation of microhybrid, packable and nanofilled resin composites in Class I restorationsJournal of Oral Rehabilitation37(
    7
    )532-537.
  • 105
    Stefanski S,
    &
    van Dijken JW
    (2012) Clinical performance of a nanofilled resin composite with and without an intermediary layer of flowable composite: A 2-year evaluationClinical Oral Investigations16(
    1
    )147-153.
  • 106
    Arhun N,
    Celik C,
    &
    Yamanel K
    (2010) Clinical evaluation of resin-based composites in posterior restorations: Two-year resultsOperative Dentistry35(
    4
    )397-404.
  • 107
    Palaniappan S,
    Bharadwaj D,
    Mattar DL,
    Peumans M,
    Van Meerbeek B,
    &
    Lambrechts P
    (2009) Three-year randomized clinical trial to evaluate the clinical performance and wear of a nanocomposite versus a hybrid compositeDental Materials25(
    11
    )1302-1314.
  • 108
    Palaniappan S,
    Elsen L,
    Lijnen I,
    Peumans M,
    Van Meerbeek B,
    &
    Lambrechts P
    (2010) Three-year randomised clinical trial to evaluate the clinical performance, quantitative and qualitative wear patterns of hybrid composite restorationsClinical Oral Investigations14(
    4
    )441-458.
  • 109
    de Andrade AK,
    Duarte RM,
    Guedes Lima SJ,
    Passos TA,
    Lima KC,
    &
    Montes MA
    (2011) Nanohybrid versus nanofill composite in class I cavities: Margin analysis after 12 monthsMicroscopy Research and Technique74(
    1
    )23-27.
  • 110
    de Andrade AK,
    Duarte RM,
    Medeiros e Silva FD,
    Batista AU,
    Lima KC,
    Pontual ML,
    &
    Montes MA
    (2011) 30-Month randomised clinical trial to evaluate the clinical performance of a nanofill and a nanohybrid compositeJournal of Dentistry39(
    1
    )8-15.
  • 111
    Turkun LS,
    &
    Celik EU
    (2008) Noncarious class V lesions restored with a polyacid modified resin composite and a nanocomposite: A two-year clinical trialJournal of Adhesive Dentistry10(
    5
    )399-405.
  • 112
    Palaniappan S,
    Bharadwaj D,
    Mattar DL,
    Peumans M,
    Van Meerbeek B,
    &
    Lambrechts P
    (2011) Nanofilled and microhybrid composite restorations: Five-year clinical wear performancesDental Materials27(
    7
    )692-700.
  • 113
    Palaniappan S,
    Elsen L,
    Lijnen I,
    Peumans M,
    Van Meerbeek B,
    &
    Lambrechts P
    (2012) Nanohybrid and microfilled hybrid versus conventional hybrid composite restorations: 5-year clinical wear performanceClinical Oral Investigations16(
    1
    )181-190.
  • 114
    Bayne SC,
    Taylor DF,
    &
    Heymann HO
    (1992) Protection hypothesis for composite wearDental Materials8(
    5
    )305-309.
  • 115
    Cetin AR,
    Unlu N,
    &
    Cobanoglu N
    (2013) A five-year clinical evaluation of direct nanofilled and indirect composite resin restorations in posterior teethOperative Dentistry38(
    2
    )E1-E11.
  • 116
    van Dijken JW,
    &
    Pallesen U
    (2013) A six-year prospective randomized study of a nano-hybrid and a conventional hybrid resin composite in Class II restorationsDental Materials29(
    2
    )191-198.
  • 117
    van Dijken JW,
    &
    Pallesen U
    (2014) A randomized 10-year prospective follow-up of Class II nanohybrid and conventional hybrid resin composite restorationsJournal of Adhesive Dentistry16(
    6
    )585-592.
  • 118
    Frankenberger R,
    Reinelt C,
    &
    Kramer N
    (2014) Nanohybrid vs. fine hybrid composite in extended class II cavities: 8-year resultsClinical Oral Investigations18(
    1
    )125-137.
Copyright: Operative Dentistry, 2018 2018

Contributor Notes

Corresponding author: PO Box 3030, Irbid 22110, Jordan; e-mail: hjsa@just.edu.jo
Accepted: 08 Dec 2017
  • Download PDF