Editorial Type:
Article Category: Research Article
 | 
Online Publication Date: 27 Mar 2020

Influence of Material and Surface Roughness of Resin Composite Cements on Fibroblast Behavior

,
,
,
, and
Page Range: 528 – 536
DOI: 10.2341/19-113-L
Save
Download PDF

Clinical Relevance

A well-polished cement surface increases the viability and spreading of gingival fibroblasts. The tested resin composite cements did not reveal any cytotoxic effects.

SUMMARY

Objective: This in vitro study aimed to investigate the effect of cement type and roughness on the viability and cell morphology of human gingival fibroblasts (HGF-1).

Methods and Materials: Discs of three adhesive (Panavia V5 [PV5], Multilink Automix [MLA], RelyX Ultimate [RUL] and three self-adhesive (Panavia SA plus [PSA], SpeedCem plus [SCP], RelyX Unicem [RUN]) resin composite cements were prepared with three different roughnesses using silica paper grit P180, P400, or P2500. The cement specimens were characterized by surface roughness and energy-dispersive X-ray spectroscopic mapping. A viability assay was performed after 24 hours of incubation of HGF-1 cells on cement specimens. Cell morphology was examined with scanning electron microscopy.

Results: The roughness of the specimens did not differ significantly among the different resin composite cements. Mean Ra values for the three surface treatments were 1.62 ± 0.34 μm for P180, 0.79 ± 0.20 μm for P400, and 0.17 ± 0.08 μm for P2500. HGF-1 viability was significantly influenced by the cement material and the specimens’ roughness, with the highest viability for PSA ≥ RUN = MLA ≥ SCP = PV5 > RUL (p<0.05) and for P2500 = P400 > P180 (p<0.001). Cell morphology did not vary among the materials but was affected by the surface roughness.

Conclusion: The composition of resin composite cements significantly affects the cell viability of HGF-1. Smooth resin composite cement surfaces with an Ra of 0.2–0.8 μm accelerate flat cell spreading and formation of filopodia.

INTRODUCTION

Most dental restorations are fixed with cement material, and the selection of cement depends on the type of restoration, the restorative material, and the tooth or implant abutment surface contacting the restoration. Zinc phosphate cement has been used for decades for fixation of restorations, with exact fit providing thin cement layers of a minimum of 20 μm.1 However, in restorations with larger cement margins, zinc oxide phosphate cement is more susceptible to hydrolytic degradation compared with resinous cements.2 In laboratory and clinical situations, the cement margin width is reported to vary between 20 and 373 μm.37 The introduction of resin composite cements provided materials that could adhere to etched enamel and to a lower degree also to dentin surfaces.8 In addition, adhesion to the restoration was achieved, for instance, after etching and silanization of feldspar or lithium-disilicate ceramics. These adhesive characteristics of resin composite cements enabled the design of nonretentive restorations, even nonprep restorations, and facilitated a shift toward noninvasive preparation designs.9 After inserting a reconstruction with resin composite cement, excess cement is initially removed with either foam pellets or by light curing for two seconds to achieve an initial polymerization followed by removal with a hand instrument of the consequently slightly hardened cement. Especially in the subgingival and interdental area, excess cement is difficult to eliminate, and residual cement is often found on parts of the reconstruction or surrounding tissue, acting as a potential cause of inflammation. 10,11 Afterward, the cement margin can be smoothed with fine burs and rubber polishers to remove the oxygen inhibition layer containing unreacted monomer and to prevent extensive biofilm formation.12

For implant reconstructions, screw retention is generally preferred because of the retrievability in cases with complications or need for restoration renewal.13 Direct intraoral cementation can be indicated for compensation of divergent implant angulations or when zirconia implants are used, which are mainly one-piece designs.14,15 Even with screw-retained implant restorations, resin composite cements are used for the fixation of computer-aided design/computer-aided manufacturing full-ceramic fixed-dental prostheses, which are extraorally cemented on titanium-bonding bases (Ti-Base) and then screwed onto the intraosseous implant part.16

Around teeth and implants, the junctional epithelium and the gingival fibroblasts in the connective tissue compartment provide a seal between the oral cavity and the bone by their hemidesmosomes, thus preventing bacteria and bacterial toxins from migrating along the interface between soft tissue and reconstruction. The cement and restorative materials, which are in contact with soft tissues, should therefore promote fibroblast cell adhesion and growth while also impeding extensive biofilm formation.17In vitro tests with human gingival fibroblasts (HGF-1) cells are commonly performed to evaluate the biocompatibility of transgingival implant components. 1821 On dental cements, the highest viability of fibroblasts was found on noneugenol zinc oxide, followed by zinc phosphate, zinc oxide, and resin composite cement.22 Furthermore, fibroblast adhesion to resin composite cement was found to be lower than to dentin and to titanium but higher than to zirconia.23 Previously, it was demonstrated that the bacterial adhesion on dental cement is significantly influenced by the material composition 12,22,24 and the surface roughness.22 Biofilm formation was significantly lower on resin composite cement specimens having a surface roughness with an Ra value of 0.1 μm compared to those with an Ra value of 1.2 μm.12 However, it is currently unknown if the composition and roughness of resin composite cements affect the behavior of the fibroblasts, as was found for bacterial biofilm formation. Hence, the purpose of this comparative experimental in vitro study was to evaluate whether the material composition and surface roughness of composite cements influence the viability and morphology of gingival fibroblasts. The null hypothesis was that the viability of HGFs does not differ among resin composite cements of different composition and roughness.

METHODS AND MATERIALS

The viability and morphology of HGF-1 cells were investigated on three adhesive (Panavia V5 [PV5], Multilink Automix [MLA], RelyX Ultimate [RUL]) and three self-adhesive (Panavia SA plus [PSA], SpeedCem plus [SCP], RelyX Unicem 2 Automix [RUN]) resin composite cements with three different surface roughnesses. Cell viability assays and scanning electron microscopy (SEM) were performed after 24 hours of cell cultivation on the cement specimens. The cement materials were chosen in accordance with a previous study of biofilm formation 7 and are listed in Table 1.

Table 1: Composition of Resin Composite Cement Materials
Table 1:

Cement Specimens

Discs of each cement were produced using a ring-shaped Teflon mold with an inner diameter of 13 mm and a thickness of 1 mm. The dimension of the specimens was chosen to allow them to be fitted into a 24-well plate, where cells were later cultivated on the specimens. The mold was placed on Mylar foil located on a glass object slide. The cement was filled into the mold, which was again covered with a Mylar foil and a glass slide and fixed with clamps from two sides. The Mylar foil was used to obtain an even specimen surface and to simulate the clinical situation, in which the initial oxygen inhibition layer would be removed by polishing the cement margin.

The cement was light cured from both sides for 60 seconds each (Elipar DeepCure-S, 3M ESPE, Seefeld, Germany) and then stored in an incubator (CTS T-4025, CTS Clima Temperatur Systeme GmbH, Hechingen, Germany) at 37°C for 15 minutes according to ISO 4049 to await further polymerization. Cement specimens were then removed from the molds, and the surfaces were wet polished (Minitech 265, Presi, Hagen, Germany) with silica carbide paper (Presi). Three different surface structures were created to imitate the following clinical situations: 1) polishing the cement margin with a rough red proxoshape diamond bur (silica carbide paper P180), 2) polishing with a coarse polisher (P400), and 3) polishing with a fine polisher (P2500).12

After grinding, the specimens were cleaned with distilled water in an ultrasonic bath (TPC-15, Telsonic, Bronschhofen, Switzerland) for four minutes, followed by four minutes in 70% ethanol and another four minutes in distilled water; air dried; and stored in sterile 24-well plates. This cleaning process was required to avoid contamination of cement specimens used for cell experiments.

To determine the composition of the cement materials, one specimen per cement was polished with P1200/P4000 and observed with SEM followed by an energy-dispersive X-ray (EDX) spectroscopy mapping (FEI Nova NanoSEM230, Thermo Fisher Scientific, Waltham, MA, USA) at 15 kV and 5000× magnification over 12 hours. The surface roughness of three specimens of each cement type and roughness was measured three times using a tactile profilometer (T1000/TKK50, Hommelwerke, Schwenningen, Germany). Measurements were taken over a distance of 4.8 mm (T1E, tip 5 μm 90°, 1.6 mN, Hommel-Etamic/Jenoptik, Jena, Germany). Ra values were determined as the arithmetic average of the absolute values of the profile heights (peaks/valleys) over the evaluation length.

Cell Cultivation

Human primary gingival fibroblast cells (HGF-1, ATCC American Type Culture Collection, Manassas, VA, USA) were cultivated in Dulbecco’s Modified Eagle Medium (DMEM high glucose, Sigma-Aldrich, Darmstadt, Germany) with 1% L-glutamine (Gibco, Thermo Fisher Scientific), 1% sodium-pyruvate (Gibco, Thermo Fisher Scientific), 1% penicillin-streptomycin (Sigma-Aldrich), and 1% amphotericin B solution (Sigma-Aldrich) as well as 10% fetal calf serum (bioswisstec, Schaffhausen, Switzerland) at 37°C with 5% CO2. The cultures were kept for an average of three weeks in the incubator (B5060 EK/CO2, Heraeus, Hanau, Germany) until confluence, while the culture medium was changed every second day. Cells were then washed twice with phosphate-buffered saline (PBS) solution (Gibco, Thermo Fisher Scientific) without calcium and magnesium and detached using 0.5% trypsin/0.2% EDTA solution (Sigma-Aldrich). In 24-well plates, 104 cells in a drop of 140 μL cell culture medium were seeded per specimen surface. To prevent cells from growing on well bottoms, the drops were carefully placed on each specimen. After one hour in the incubator, an additional 200 μL of cell culture medium was added, and cells were cultivated for another 23 hours in the incubator. Polystyrene discs (Thermanox, Faust Laborbedarf, Schaffhausen, Switzerland) served as the control.

Cell Viability Assay

To evaluate the effect of cement material and roughness on gingival fibroblasts, a WST-1 cell viability assay (cell proliferation reagent WST-1, Sigma Aldrich) was performed after 24 hours. In this assay, the stable water-soluble tetrazolium salt WST-1 is converted to a soluble formazan by a cellular mechanism, and the amount of formazan directly correlates to the number of metabolically active cells. Cells were seeded on all cements with three different roughnesses in triplicates, meaning three specimens per cement and roughness were seeded, and the experiments were repeated three times (n=9 per group; 162 specimens in total).

Polystyrene discs with a diameter of 13 mm served as control (n=9). In addition, one specimen per group and experiment was not seeded with cells and served as a blank (n=3 per group). After 24 hours, specimens were rinsed once with PBS, and 300 μL of WST-1 solution mixed with DMEM (1:3) was added to each well and incubated for two hours. Afterward, 200 μL of the supernatant was transferred to a 96-well plate, and the optical density (OD) was recorded at 490 nm with a microplate reader (RT-2100C Microplate Reader, Versamax, Molecular Devices LLC, San Jose, CA, USA). A cell viability of 100% was attributed to the cells grown on polystyrene control discs. The relative cell viability was calculated using the following equation:

Cell Morphology

Cell morphology after 24 hours was visualized on one additional specimen per group for three repetitions (n=3 per group) using SEM (FEI Nova Nano-SEM230, Thermo Fisher Scientific) at 15 kV. Cells on the specimens were rinsed with PBS, fixed with 2.5% glutaraldehyde (Sigma-Aldrich) for 20 minutes at room temperature, rinsed with PBS and distilled water, dehydrated with ethanol (30%, 50%, 70%, 80%, 90%, 96%, abs), critical point dried (Autosamdri-815, Tousimis Research Corporation, Rockville, MD, USA), and gold sputtered.

Statistical Analysis

Values of surface roughness and cell viability were tested for normal distribution using Shapiro-Wilk test. Two-way analysis of variance was applied afterward to determine the effect of roughness and material. Differences within subgroups were evaluated with post hoc Fisher least significant difference test. The level of significance was set to α = 0.05.

RESULTS

Cement Characterization

EDX mapping of the cements provided the weight% of the elements present on the surfaces of the specimens (Figure 1A). Based on the distribution of the elements displayed in the corresponding SEM images, the filler composition was determined (Figure 1B).

Figure 1.Figure 1.Figure 1.
Figure 1. (A): EDX analysis of elements present in weight% at resin composite cement surfaces. (B): SEM images of resin composite cement surfaces. Ceramic fillers determined with EDX mapping are indicated with black arrows. PV5, Panavia V5; PSA, Panavia SA plus; MLA, Multilink Automix; SCP, SpeedCem plus; RUL, RelyX Ultimate; RUN, RelyX Unicem 2 Automix.

Citation: Operative Dentistry 45, 5; 10.2341/19-113-L

There was no statistical difference in Ra values between the different cement types when polished to the same roughness (p=0.204). The three different polishing approaches resulted in significantly different Ra values, with Ra = 1.62 ± 0.34 μm for P180, which was significantly higher than Ra = 0.79 ± 0.20 μm for P400 (p<0.001), and significantly higher than Ra = 0.17 ± 0.08 μm for P2500 (p<0.001).

Cell viability

Cement material (p=0.002) and surface roughness (p<0.001) significantly affected the viability of HGF-1 cells. Cell viability was significantly highest for PSA ≥ RUN = MLA ≥ SCP = PV5 > RUL (p<0.05). Surface treatment with silica carbide paper grit 180 resulted in significantly lower cell viability (p<0.001) than treatment with grit 400 and 2500, which did not differ significantly (p=0.606). Mean cell viability varied between 73% ± 6% for RUL (P180) and 92% ± 13% for PSA (P400) and was smallest for P180 for all cements (Table 2). The correlation between cell viability and the surface roughness of the specimens on which the cells were cultured is displayed in Figure 2.

Table 2: Relative Cell Viability (%) of HGF-1 on Resin Composite Cements PV5, PSA, MLA, SCP, RUL, and RUN With Surface Pretreatment Grits P180, P400, and P2500a
Table 2:
Figure 2.Figure 2.Figure 2.
Figure 2. Correlation between surface roughness and relative cell viability for HGF-1 on all cements.

Citation: Operative Dentistry 45, 5; 10.2341/19-113-L

Cell Morphology

SEM images of cells on the specimens revealed no visible differences in cell morphology or growth pattern of the fibroblasts between the different cements with the same surface roughness. On rough specimens (P180 Ra=1.62 μm), fibroblast cells aligned themselves parallel to the direction of the grinding grooves and displayed an elongated morphology, while on smooth surfaces (P2500 Ra=0.17 μm), cells spread planar and without a specific orientation (Figure 3). On surfaces treated with silica paper grit P400 (Ra=0.79 μm), both cell morphologies were observed. Filopodia were formed by cells on all surfaces but most prominently by cells on surfaces treated with silica paper grit P2500.

Figure 3.Figure 3.Figure 3.
Figure 3. SEM images of HGF-1 cells on a randomly selected cement (MLA: Multilink Automix) surface with pretreatment of grit P180, P400, or P2500 (first row 200×, second row 3000×).

Citation: Operative Dentistry 45, 5; 10.2341/19-113-L

DISCUSSION

This in vitro study investigated the influence of different resin composite cements with varying surface roughnesses on the viability of gingival fibroblasts. The results demonstrated that cell viability was significantly higher on surfaces with a roughness Ra value of between 0.2 and 0.8 μm; hence, the null hypothesis was rejected. On these smoother surfaces, cells spread flat, and the formation of filopodia was observed.

Based on the composition given by the manufacturers in combination with the mapping images determined with SEM/EDX, the respective inorganic fillers of the resin composite cements could be identified. The characterization of the specimens’ filler contents and morphologies revealed that similar inorganic fillers were selected for the adhesive and self-adhesive cement by the same manufacturer, especially for RUL and RUN, which also presented identical surface structures. For PV5 barium glass, alumina and silica could be identified, while PSA was mainly composed of irregular-sized barium glass fillers. Barium glass and additionally ytterbium trifluoride were present in MLA and SCP. To MLA, zirconia fillers were added, while SCP contained chunks of silica fillers. Both RUN and RUL contained silica particles and aluminum fluoride fillers. The weight% of the analyzed elements corresponded to the fillers visible in the SEM images. Neither the type of cement, adhesive or self-adhesive, nor the cement composition correlated with cell viability among the investigated cements. Using EDX analysis, only inorganic compositions could be determined, and organic compositions are displayed as contents of carbon and partially oxygen.

In addition, elements present in very small amounts, such as copper, which may have affected cell behavior, could not be captured because of the limited sensitivity of the detector and the presence of heavier elements that potentially covered the signal from lighter elements. For the organic components, it was reported that monomer release induces toxic effects, especially for cements that are not sufficiently polymerized.25 The in vitro cytotoxicity of monomers to HGFs has been reported to be significantly highest for bisphenol A-glycidyl methacrylate (PV5, PSA, MLA) > urethane dimethacrylate (MLA, SCP) > triethylene glycol dimethacrylate (PV5, PSA, SCP) > 2-hydroxyethyl methacrylate (PSA, MLA).26,27 However, in the present study, the contents of those monomers in the cements as indicated by the manufacturers were not correlated with cell viability. The manufacturer of the RUL and RUN cements did not specify their monomer contents. It was demonstrated that effective polymerization of methacrylate-based materials improves their biocompatibility, physical properties, and clinical performance. 28 Measurements of the polymerization degree of the cement specimens and consequently an estimation of potential monomers leaking from the surfaces would have allowed further interpretation of the results.

On all cements—except RUL on the roughest surface—fibroblast viability values of HGF-1 were greater than 75% compared with the control cells grown on polystyrene, which is categorized as noncytotoxic according to ISO standard 10993-5.

The effect of surface roughness on the behavior of HGF-1 is controversial.2932 A surface roughness with an Ra value between 0.15 and 0.25 μm has been proposed to provide optimal conditions for growth of HGF-1 cells.31 The surface roughness of the specimens in the present study was chosen in accordance with the roughness relevant in a clinical situation by polishing the cement margin with a diamond bur (Ra=1.6 μm) or a coarse (Ra=0.8 μm) or fine intraoral polisher (Ra=0.2 μm).12 Since the viability of HGF-1 cells on cement surfaces with an Ra value of 1.6 μm was significantly lower than on smoother surfaces, the cement margin should be finished with rubber polishers, which agrees with previous findings for biofilm formation on resin composite cements.12

Interestingly, it has been proposed that cell attachment is influenced by surface roughness between Ra 0.5 μm and 0.2 μm and that wettability plays a major role in the surface roughness at an Ra value of 0.2 μm or less.33 It can be speculated that the cement’s microstructure, defined by the filler size and distribution, which are not considered within the Ra measurements, may have also affected the cell viability. Since the morphology of RUL and RUN was very similar while different cell viability was observed, it is more likely that the difference between those cements is due to the chemical composition of the surface.

HGFs spread more widely, and the formation of filopodia was increased, on smooth surfaces with an Ra value <0.8 μm than on the rough specimens with an Ra value of 1.6 μm. The behavior of HGFs on rough compared with smooth surfaces has been described in several studies on titanium.17,34,35 The current study confirms this behavior on all tested cements. HGFs were oriented on rougher surfaces along grooves, which is referred to as contact guidance.17,34,35 Cells on smooth surfaces were randomly distributed and not oriented. The cell size of HGF-1 (15 to 150 μm)36,37 was within the range of the width of the cement margin (20 to 373 μm).37 During cementation in a clinical situation, cement is often smeared over larger areas of the reconstruction and is difficult to be fully retrieved. Therefore, the surface structure and cytotoxic potential of cements are important factors influencing the adaption of gingival tissue around a tooth or an implant abutment.

The present results on how the inorganic composition and surface roughness potentially affect cell behavior highlights the complexity of material influencing cell behavior. Numerous other factors such as surface wettability, aging, and the formation of an oxygen inhibition layer, as well as the interaction with saliva and blood at the cement surfaces, may also affect the behavior of fibroblasts in a clinical situation and should be evaluated in further studies.

CONCLUSIONS

This study is the first to provide in vitro data on how the surface roughness and composition of resin composite cements affect HGF cell viability. A smooth surface increases viability after 24 hours. Hence, clinicians should finish the surface of the cement margin with rubber polishers to obtain an optimal substrate for fibroblast growth. With respect to viability, all tested resin composite cements displayed no cytotoxic reactions and can be recommended for clinical use.

Acknowledgements

The authors are grateful to Fredy Schmidli for performing the SEM imaging and to Martha Imholz for the cell laboratory support at the University of Basel.

    Regulatory Statement This study was conducted in accordance with all the provisions of the local human subjects oversight committee guidelines and policies of the University Center for Dental Medicine, University of Basel, Switzerland. Conflict of Interest In addition to his function as the head of the Division of Dental Materials and Engineering at the University of Basel, Switzerland, Jens Fischer is the manager of research and development at VITA Zahnfabrik, Bad Säckingen, Germany. All other authors declare no conflict of interest.

REFERENCES

  • 1.
    White SN & YuZ( 1992) Film thickness of new adhesive luting agentsJournal of Prosthetic Dentistry67(
    6
    ) 782785.
  • 2.
    Fraga RC, Luca-Fraga LR, & PimentaLA( 2000) Physical properties of resinous cements: an in vitro studyJournal of Oral Rehabilitation27(
    12
    ) 10641067.
  • 3.
    Bindl A & MörmannWH( 2003) Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crownsEuropean Journal of Oral Sciences111(
    2
    ) 163169.
  • 4.
    Rojpaibool T & LeevailojC( 2017) Fracture resistance of lithium disilicate ceramics bonded to enamel or dentin using different resin cement types and film thicknessesJournal of Prosthodontics26(
    2
    ) 141149.
  • 5.
    Arena A, Baldissara P, Ciocca L, Scotti R, & MonacoC( 2019) Influence of preparation design and spacing parameters on the risk of chipping of crowns made with Cerec Bluecam before cementationJournal of Prosthodontic Research63(
    1
    ) 100104.
  • 6.
    Zaugg LK, Zehnder I, Rohr N, Fischer J, & ZitzmannNU( 2018) The effects of crown venting or pre-cementing of CAD/CAM-constructed all-ceramic crowns luted on YTZ implants on marginal cement excessClinical Oral Implants Research29(
    1
    ) 8290.
  • 7.
    Kokubo Y, Tsumita M, Kano T, Sakurai S, & FukushimaS( 2011) Clinical marginal and internal gaps of zirconia all-ceramic crownsJournal of Prosthodontic Research55(
    1
    ) 4043.
  • 8.
    Rohr N & FischerJ( 2017) Tooth surface treatment strategies for adhesive cementationJournal of Advanced Prosthodontics9(
    2
    ) 8592.
  • 9.
    Edelhoff D & OzcanM( 2007) To what extent does the longevity of fixed dental prostheses depend on the function of the cement? Working group 4 materials: cementation. Clinical Oral Implants Research18(
    Supplement 3
    ) 193204.
  • 10.
    Sancho-Puchades M, Crameri D, Özcan M, Sailer I, Jung RE, Hämmerle CHF, & ThomaDS( 2017) The influence of the emergence profile on the amount of undetected cement excess after delivery of cement-retained implant reconstructionsClinical Oral Implants Research28(
    12
    ) 15151522.
  • 11.
    Anami LC, Pereira CA, Guerra E, Assunção e Souza RO, Jorge AO, & BottinoMA( 2012) Morphology and bacterial colonisation of tooth/ceramic restoration interface after different cement excess removal techniquesJournal of Dentistry40(
    9
    ) 742749.
  • 12.
    Glauser S, Astasov-Frauenhoffer M, Müller JA, Fischer J, Waltimo T, & RohrN( 2017) Bacterial colonization of resin composite cements: influence of material composition and surface roughnessEuropean Journal of Oral Sciences125(
    4
    ) 294302.
  • 13.
    Staubli N, Walter C, Schmidt JC, Weiger R, & ZitzmannNU( 2017) Excess cement and the risk of peri-implant disease—a systematic reviewClinical Oral Implants Research28(
    10
    ) 12781290.
  • 14.
    Pieralli S, Kohal RJ, Jung RE, Vach K, & SpiesBC( 2017) Clinical outcomes of zirconia dental implants: a systematic reviewJournal of Dental Research96(
    1
    ) 3846.
  • 15.
    Balmer M, Spies BC, Vach K, Kohal RJ, Hämmerle CHF, & JungRE( 2018) Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: a prospective multicenter studyClinical Oral Implants Research29(
    3
    ) 290299.
  • 16.
    Lopes ACO, Machado CM, Bonjardim LR, Bergamo ETP, Ramalho IS, Witek L, Coelho PG, & BonfanteEA( 2019) The effect of CAD/CAM crown material and cement type on retention to implant abutmentsJournal of Prosthodontics28(
    2
    ) 552556.
  • 17.
    Ferraris S, Truffa Giachet F, Miola M, Bertone E, Varesano A, Vineis C, Cochis A, Sorrentino R, Rimondini L, & SprianoS( 2017) Nanogrooves and keratin nanofibers on titanium surfaces aimed at driving gingival fibroblasts alignment and proliferation without increasing bacterial adhesionMaterials Science and Engineering C Materials for Biological Applications76112.
  • 18.
    Yang Y, Zhou J, Liu X, Zheng M, Yang J, & TanJ( 2015) Ultraviolet light-treated zirconia with different roughness affects function of human gingival fibroblasts in vitro: the potential surface modification developed from implant to abutmentJournal of Biomedical Materials Research—Part B: Applied Biomaterials103(
    1
    ) 116124.
  • 19.
    Raffaelli L, Rossi Iommetti P, Piccioni E, Toesca A, Serini S, Resci F, Missori M, De Spirito M, Manicone PF, & CalvielloG( 2008) Growth, viability, adhesion potential, and fibronectin expression in fibroblasts cultured on zirconia or feldspatic ceramics in vitroJournal of Biomedical Materials Research Part B: Applied Biomaterials86(
    4
    ) 959968.
  • 20.
    Neunzehn J, Lüttenberg B, & WiesmannHP( 2018) Investigation of biomaterials by human epithelial gingiva cells: an in vitro studyHead & Face Medicine835.
  • 21.
    Grenade C, De Pauw-Gillet MC, Gailly P, Vanheusden A, & MainjotA( 2016) Biocompatibility of polymer-infiltrated-ceramic-network (PICN) materials with human gingival fibroblasts (HGFs)Dental Materials39(
    2
    ) 11521164.
  • 22.
    Rodriguez LC, Saba JN, Chung KH, Wadhwani C, & RodriguesDC( 2017) In vitro effects of dental cements on hard and soft tissues associated with dental implantsJournal of Prosthetic Dentistry118(
    1
    ) 3135.
  • 23.
    Mehl C, Kern M, Schütte AM, Kadem LF, & Selhuber-UnkelC( 2016) Adhesion of living cells to abutment materials, dentin, and adhesive luting cement with different surface qualitiesDental Materials32(
    12
    ) 15241535.
  • 24.
    Raval NC, Wadhwani CP, Jain S, & DarveauRP( 2015) The interaction of implant luting cements and oral bacteria linked to peri-implant disease: an in vitro analysis of planktonic and biofilm growth—a preliminary studyClinical Implant Dentistry and Related Research17(
    6
    ) 10291035.
  • 25.
    Lin-Gibson S, Sung L, Forster AM, Hu H, Cheng Y, & LinNJ( 2009) Effects of filler type and content on mechanical properties of photopolymerizable composites measured across two-dimensional combinatorial arraysActa Biomaterialia5(
    6
    ) 20842094.
  • 26.
    Reichl FX, Esters M, Simon S, Seiss M, Kehe K, Kleinsasser N, Folwaczny M, Glas J, & HickelR( 2006) Cell death effects of resin-based dental material compounds and mercurials in human gingival fibroblastsArchives of Toxicology80(
    6
    ) 370377.
  • 27.
    Gupta SK, Saxena P, Pant VA, & PantAB( 2012) Release and toxicity of dental resin composite.Toxicology International19(
    3
    ) 225234.
  • 28.
    Ergun G, Egilmez F, & YilmazS( 2011) Effect of reduced exposure times on the cytotoxicity of resin luting cements cured by high-power LEDJournal of Applied Oral Sciences19(
    3
    ) 286292.
  • 29.
    Nothdurft FP, Fontana D, Ruppenthal S, May A, Aktas C, Mehraein Y, Lipp P, & KaestnerL( 2015) Differential behavior of fibroblasts and epithelial cells on structured implant abutment materials: a comparison of materials and surface topographiesClinical Implant Dentistry and Related Research17(
    6
    ) 12371249.
  • 30.
    Rutkunas V, Bukelskiene V, Sabaliauskas V, Balciunas E, Malinauskas M, & BaltriukieneD( 2015) Assessment of human gingival fibroblast interaction with dental implant abutment materialsJournal of Materials Science: Materials in Medicine26(
    4
    ) 169.
  • 31.
    Gómez-Florit M, Ramis JM, Xing R, Taxt-Lamolle S, Haugen HJ, Lyngstadaas SP, & MonjoM( 2014) Differential response of human gingival fibroblasts to titanium- and titanium-zirconium-modified surfacesJournal of Periodontal Research49(
    4
    ) 425436.
  • 32.
    Mustafa K, Silva Lopez B, Hultenby K, Wennerberg A, & ArvidsonK( 1998) Attachment and proliferation of human oral fibroblasts to titanium surfaces blasted with TiO2 particles: a scanning electron microscopic and histomorphometric analysisClinical Oral Implants Research9(
    3
    ) 195207.
  • 33.
    Kim YS, Shin SY, Moon SK, & YangSM( 2015) Surface properties correlated with the human gingival fibroblasts attachment on various materials for implant abutments: a multiple regression analysisActa Odontologica Scandinavica73(
    1
    ) 3847.
  • 34.
    Guillem-Marti J, Delgado L, Godoy-Gallardo M, Pegueroles M, Herrero M, & GilFJ( 2013) Fibroblast adhesion and activation onto micro-machined titanium surfacesClinical Oral Implants Research24(
    7
    ) 770780.
  • 35.
    Pae A, Lee H, Kim HS, Kwon YD, & WooYH( 2009) Attachment and growth behaviour of human gingival fibroblasts on titanium and zirconia ceramic surfacesBiomedical Materials4(
    2
    ) 025005.
  • 36.
    Qin Z, Worthen CA, & QuanT( 2017) Cell-size-dependent upregulation of HGF expression in dermal fibroblasts: impact on human skin connective tissue agingJournal of Dermatological Science88(
    3
    ) 289297.
  • 37.
    Herráez-Galindo C, Rizo-Gorrita M, Luna-Oliva I, Serrera-Figallo MÁ, Castillo-Oyagüe R, & Torres-LagaresD( 2019) In vitro comparative study of fibroblastic behaviour on polymethacrylate (PMMA) and lithium disilicate polymer surfacesPolymers11(
    4
    ) E744.
Copyright: 2020
Figure 1.
Figure 1.

(A): EDX analysis of elements present in weight% at resin composite cement surfaces. (B): SEM images of resin composite cement surfaces. Ceramic fillers determined with EDX mapping are indicated with black arrows. PV5, Panavia V5; PSA, Panavia SA plus; MLA, Multilink Automix; SCP, SpeedCem plus; RUL, RelyX Ultimate; RUN, RelyX Unicem 2 Automix.


Figure 2.
Figure 2.

Correlation between surface roughness and relative cell viability for HGF-1 on all cements.


Figure 3.
Figure 3.

SEM images of HGF-1 cells on a randomly selected cement (MLA: Multilink Automix) surface with pretreatment of grit P180, P400, or P2500 (first row 200×, second row 3000×).


Contributor Notes

*†Nadja Rohr, Dr Med Dent, Biomaterials and Technology, Clinic for Reconstructive Dentistry, University Center for Dental Medicine Basel, Basel, Switzerland

Nadine Bertschinger, Med Dent, Clinic for Reconstructive Dentistry, University Center for Dental Medicine Basel, Basel, Switzerland

Jens Fischer, Prof Dr Dr, Biomaterials and Technology, Clinic for Reconstructive Dentistry, University Center for Dental Medicine Basel, Basel, Switzerland

Andreas Filippi, Prof Dr, Department of Oral Surgery, University Center for Dental Medicine Basel, Basel, Switzerland

Nicola Ursula Zitzmann, Prof Dr PhD, Clinic for Reconstructive Dentistry, University Center for Dental Medicine Basel, Basel, Switzerland

*Corresponding author: Mattenstrasse 40, CH-4058 Basel, Switzerland; e-mail: nadja.rohr@unibas.ch

Authors contributed equally to this work.

Accepted: 31 Aug 2019
  • Download PDF