Clinical Performance of Filled/Nanofilled Versus Nonfilled Adhesive Systems in Noncarious Cervical Lesions: A Systematic Review and Meta-analysis
The use of filled adhesive systems does not influence the clinical performance of the adhesive restoration in noncarious cervical lesions. The aim of this meta-analysis was to investigate the clinical performance of filled vs unfilled adhesive systems when applied in noncarious cervical lesions. A systematic search was performed in PubMed, Scopus, Web of Science, LILACS, BBO, Cochrane Library, and SIGLE. Gray literature was also screened. Only randomized controlled clinical trials were included. The risk of bias of the studies was evaluated using the Cochrane Collaboration’s tool. A random-effects meta-analysis was conducted to compare the retention rate, marginal discoloration, and secondary caries of noncarious cervical lesions restored with filled adhesives vs unfilled adhesives. The quality of the body of evidence was assessed using the GRADE approach. A total of 3662 studies were identified after removal of duplicates. Twenty-nine studies remained for qualitative analyses and 28 studies for the meta-analysis. Only one study was judged to have a low risk of bias, and the other 28 were considered to have unclear risk of bias. There was no statistically significant difference between filled adhesives compared with unfilled adhesives in relation to loss of retention, marginal discoloration, or secondary caries at any of the follow-up periods (12–18 months, 24–30 months, 3 years, and 5 years or longer). The quality of evidence was graded as moderate for most outcomes at the respective follow-ups, except when there was an explained heterogeneity, which occurred mainly for loss of retention at the 12-month to 3-year follow-up. The results did not depend on whether microfilled or nanofilled adhesives had been investigated. The addition of fillers into the composition of adhesive systems did not increase the clinical performance (retention rates, marginal discoloration, or secondary caries) of composite restorations placed in noncarious cervical lesions when compared with unfilled adhesives.Clinical Relevance
SUMMARY
Objective:
Methods and Materials:
Results:
Conclusions:
INTRODUCTION
In recent decades, because of an increasing demand for esthetic restorations, composite resins have gained a prominent role in modern restorative dentistry. Nowadays, composite resins are the most widely used dental material, representing 65% of the restorations currently placed in the United States.1,2 However, it is worth mentioning that 50% to 70% of newly placed restorations are the result of failure of preexisting restorations, which results in millions of dental care dollars spent annually on replacement of these restorations.2–4 Many of those replacements, however, are unnecessary as either the defects that led to the replacement of the restoration could be repaired adhesively with composite resins or the restorations are replaced due to economic reasons or false diagnosis by the dentist (eg, confusion of discolored margin with caries at the margins).5–7
Among several clinical problems of esthetic restorations, the bonding interface between the dentin and the direct restorative material is considered one of the Achilles’ heels of esthetic restorations. Recently published reviews have reported that although an improvement in the clinical performance of adhesive restorations has been observed, the retention rates of composite restorations placed in noncarious cervical lesions are still a clinical problem.8,9
Although the exact mechanism responsible for bond degradation is not completely understood,2 one contributing factor for debonding may arise from the low mechanical properties of the adhesive layer that bonds the composite resin material to the dental substrate. Indeed, among the substrates of this bonded interface, the adhesive layer has the lowest elastic modulus.10,11 When submitted to masticatory stresses, the adhesive layer suffers the greatest level of strain among the components. Stress that exceeds the inherent strength of the adhesive layer results in defects, cracks, or abrupt catastrophic failure of the resin-dentin bond.12,13
Adhesive systems traditionally do not contain filler particles.14 However, from a theoretical perspective and by analogy with resin composites, the addition of fillers increases the mechanical properties of the adhesive layer.15,16 This concept was called the elastic cavity wall concept.17,18 In the past, manufacturers added varying proportions of glass filler particles (microfiller 1–5 μm) in the hydrophobic bonding bottle of three-step etch-and-rinse adhesives.16,19,20 These filled adhesives were loaded up to 40–50 wt%,19 for example, of Optibond FL (Kerr Co, Orange, CA, USA) and PermaQuick (Ultradent, South Jordan, UT, USA). Because of the very good clinical performance in long-term clinical trials of these highly filled adhesives,21–24 the same strategy was used in simplified versions of two-step etch-and-rinse adhesives and in the self-etch adhesives.8
In simplified adhesives, hydrophobic resins are combined with priming and/or acidic monomers, which do not allow the addition of a large filler amount. For example, two-step etch-and-rinse adhesives contain about 8.5–15 wt% of fillers in their composition (OptiBond Solo, Kerr Co.; One-Step Plus, Bisco Inc, Schaumburg, IL, USA),16,25–27 which is less than half of the amount that is added in three-step etch-and-rinse systems. By adding large filler amounts, adhesives become more viscous, and this jeopardizes the wettability of the dental substrates.15,16
Instead of microfillers, nanofillers have been added into the adhesive systems.28 Apart from improving the strength of the adhesive layers, nanofillers can penetrate into dentin tubules and into the collagen network.16,27 Nanometer-sized silica (pure silicon dioxide) smaller than 20 nm are usually added.26,29 Some two-step etch-and-rinse systems (Prime & Bond NT and XP Bond, Dentsply Sirona and Adper Scotchbond 2 XT, 3M OralCare) and one-step self-etch adhesive systems (Clearfil S3 Bond, Kuraray and G-Bond, GC Corp) that contain nanofillers are available on the market; the amount usually ranges between 5 wt% and 10 wt%.16
Studies have shown that simplified adhesives with nanofillers may have better mechanical properties compared with unfilled adhesive systems; however, the improvement is material dependent.30,31 In addition, studies have also proven that the addition of nanofillers does not increase the bond strength to dentin.32–35 A closer view showed inconclusive results when clinical studies evaluating filled vs unfilled adhesives were evaluated.36–45 Therefore, the aim of this systematic review and meta-analysis was to answer the following focused PICO question-(P, participant; I, intervention; C, comparator; O, outcome): “Are the retention rates, marginal discoloration, and secondary caries of composite resin restorations placed in noncarious cervical lesions of patients superior when bonded with filled/nanofilled adhesives compared with unfilled adhesives?”
METHODS AND MATERIALS
The methodology described in the present study follows the PRISMA requirements (Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement).46
Protocol and Registration
The study was registered in the PROSPERO database (CRD42018093198) and performed from May to August 2018 at the State University of Ponta Grossa, Paraná, Brazil.
Information Sources and Search Strategy
The search strategy used in the PubMed database was developed based on the concepts of patient and intervention from the focused PICO question described at the end of the Introduction section. Within each concept, the controlled vocabulary (Medical Subject Headings terms) and free keywords were combined with the Boolean operator “OR.” Then, the concepts were combined with the Boolean operator “AND” to restrict the search. A filter for randomized clinical trials was also used for the PubMed database (Table 1). Table 1 also lists other electronic databases that were searched (Web of Science, Scopus, Cochrane Library, Latin American and Caribbean Health Sciences Literature database [LILACS] and Brazilian Library in Dentistry [BBO]). The reference lists of all primary studies were hand searched for additional relevant publications as well as links to related articles of each primary study in the PubMed database. No restrictions on publication date or languages were made.



The gray literature was also inspected by looking up abstracts of the International Association for Dental Research and their regional divisions (1990–2016), the System for Information on Grey literature in Europe (SIGLE), dissertations and theses using the ProQuest Dissertations and Theses full-text database, as well as the Periodicos Capes Theses database. Ongoing trials were searched in the following clinical trials registries: Current Controlled Trials (www.controlled-trials.com), International Clinical trials registry platform (http://apps.who.int/trialsearch/), ClinicalTrials.gov (www.clinicaltrials.gov), Rebec (www.rebec.gov.br), and EU Clinical Trials Register (https://www.clinicaltrialsregister.eu).
Eligibility Criteria
We included randomized clinical trials (RCTs) with parallel and split-mouth designs that compared the retention rates or other secondary outcomes (caries at restorative margins and marginal discoloration) of filled/nanofilled adhesives vs unfilled adhesives for bonding composite resin restorations in noncarious cervical lesions. RCTs were excluded if they 1) compared the same type of adhesive, 2) compared the association among different adhesives in the same restorations, or 3) compared filled vs nanofilled adhesives.
Study Selection and Data Collection Process
After database screening, duplicates were removed and possible eligible articles were selected according to title and abstracts. Full-text articles were obtained by two authors (JLG and BMM), and they were classified according to the inclusion criteria. Pilot-tested, customized extraction forms were used to register details about the studies, such as study design, participants, interventions, and outcomes. Each study received an identification number (study ID), combining the first author name and the publication year. Authors were not contacted for further information to avoid recall bias.
Data Items
When there were multiple reports of the same study (ie, reports with different follow-ups), data from all reports were extracted directly into a single data collection form to avoid overlapping data. We collected data about retention rates, marginal discoloration, and secondary caries. Usually, clinical studies on restorative materials use USPHS criteria, which are classified as Alpha, Bravo, and Charlie. We dichotomized the ordinal data into Alpha+Bravo/Charlie. For clinical studies using World Dental Federation criteria, the ordinal data were dichotomized as clinically acceptable or clinically unacceptable. The data were collected into different follow-up evaluations: 12 to 18 months, 24 to 30 months, 3 years, and 5 years or longer. When more than one adhesive of each type was included in the study, their values were combined to make a single entry. In the case of data inconsistencies between reports of different follow-up evaluations of the same study, data were collected from the most recent article. Subgroup analysis based on the type of filler (regular or nanofillers) was performed whenever data were available.
Risk of Bias in Individual Studies
Two authors (JLG and BMM) independently assessed the risk of bias of the studies selected using the Cochrane Collaboration’s tool for assessing risk of bias in randomized trials.47 The risk of bias tool contains six domains: sequence generation, allocation concealment, blinding of the outcome assessors, incomplete outcome data, selective outcome reporting, and other possible sources of bias. Each domain was judged to be at low, unclear, or high risk of bias according to the Cochrane Handbook for Systematic Reviews of Interventions 5.1.0 (http://handbook.cochrane.org).
The key domains of this study were sequence generation, allocation concealment, and examiner blinding. At the study level, the study was at low risk of bias if all key domains were at low risk of bias. If one key domain was judged as having high risk of bias, the study was considered as having a high risk of bias. If at least one key domain was judged as at unclear risk among other low-risk of bias domains, the study was considered as having unclear risk of bias. During data selection and quality assessment, any disagreements between the reviewers were solved through discussion and if needed by consulting a third reviewer (ADL).
Summary Measures and Synthesis of the Results
Dichotomous data (loss of retention, marginal discoloration, and secondary caries) were meta-analyzed to obtain a combined estimate of the overall risk difference (RD) with a 95% confidence interval. This procedure was done in different follow-ups: 12 to 18 months, 24 to 30 months, 3 years, and 5 years or longer. Subgroup analysis based on the type of filler (microfillers or nanofillers) was performed whenever data were available in each follow-up. Random effect models were used for all meta-analyses, and we assessed heterogeneity (which represents any kind of variability among studies) by using the Cochran Q test and I2 statistics. We carried out the analyses by using the software RevMan 5.3 (Review Manager version 5, The Cochrane Collaboration, Copenhagen, Denmark). In case of heterogeneity, a sensitivity analysis was performed.
Assessment of the Quality of Evidence Using GRADE
The quality of the evidence was graded for each outcome variable across studies (body of evidence) using the Grading of Recommendations: Assessment, Development and Evaluation (GRADE; http://www.gradeworkinggroup.org/) to determine the overall strength of evidence. The GRADE approach is used to contextualize or justify intervention recommendations with four levels of evidence quality, ranging from high to very low.
The GRADE approach begins with the study design (RCTs or observational studies) and then addresses five reasons (risk of bias, imprecision, inconsistency, indirectness of evidence, and publication bias) to possibly rate down the quality of evidence (one or two levels) and three to possibly rate up the quality (large effect, management of confounding factors, dose-response gradient).48 Each one of these topics was assessed as “no limitation,” “serious limitations,” or “very serious limitations” to allow categorization of the quality of the evidence for each outcome into high, moderate, low, and very low. The “high-quality” level suggests that we are very confident that the true effect lies close to the estimate of the effect. On the other extreme, a study of “very low quality” suggests that we have very little confidence in the effect estimate and the estimate reported can be substantially different from what was measured.
RESULTS
Characteristics of Included Studies
After the database screening and removal of duplicates, 3662 articles were identified (Figure 1). After title screening, 363 articles remained, and this number was reduced to 75 articles after careful examination of the abstracts (Figure 1). Among these articles, 41 were excluded for the following reasons: 1) the studies compared the same type of adhesive system (n=19),40,49–66 2) the studies used the same type of adhesive system in both study groups (n=18),67–84 and 3) the studies compared filled vs nanofilled adhesive systems (n=4).85–88



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L
A total of 32 articles remained for qualitative evaluation. From these 32 articles, 3 articles38,89,90 reported longer follow-ups of earlier studies. Therefore, there were 29 studies among 32 publications. Tables 2, 3, and 4 characterize the 29 included studies. The follow-up time of the studies varied from 12 months91–93 to 8 years.90 All studies placed multiple restorations per patient. In this design, any patient could receive as many restorations as possible, depending on the number of available noncarious cervical lesions.









The mean age of the participants was approximately 50 (±7) years.a Most of the studies (n=17, 59%) used cotton rolls and a saliva ejector to prevent contamination during the restorative protocol,b while 8 studies used a rubber dam.89,92,98,100,105–108
In few studies (n=6), the enamel was beveled.38,94,99,102,107,108 Different types of adhesive systems were used in the studies, varying from three-step etch-and-rinse adhesives (n=11)c to one-step self-etch adhesives (n=14).d The number of restorations per adhesive system used in the studies evaluated varied from 14 restorations93 to 189 restorations.107
The wet bonding technique was applied in 18 studies.e Some studies (n=8) mentioned that the application of the adhesive system was done while the adhesive was actively moved on the surface (agitation).f The time to evaporate the solvent was 5 seconds in most studies (n=14).g Adhesives were composed of different solvents such as water, ethanol, acetone, and tert-butanol. Most of the studies did not report on the operator experience (graduate, postgraduate, academic dentist, general practitioner), but for those for which this information was reported, most of the operators were academic dentists.89,90,95,99,102,105–108 Only one study reported that the operator was a graduate student.103 No study was conducted with general practitioners.
Meta-analysis
A meta-analysis was performed that included all studies with exception of one,98 which was considered at high risk of bias in the key domain examiner blinding. The risk of bias assessment is provided in Figure 2. Some follow-ups could not be integrated into the meta-analysis because of lack of information. If data were not available or could not be extracted, the study was not considered for the meta-analysis. No difference was observed between the subgroup analysis in any of the meta-analyses that had been conducted.



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L
Loss of Retention—This analysis was based on 27 studies.h In the overall analysis, which took into consideration both subgroups (filled vs unfilled and nanofilled vs unfilled), no significant difference between the two groups was detected in the follow-ups of 12 to 18 months (RD=−0.01; 95% confidence interval [CI], −0.03 to 0.02; p=0.60; Figure 3), 24 to 30 months (RD=0.00; 95% CI, −0.03 to 0.03; p=0.95; Figure 3), 3 years (RD=−0.04; 95% CI, −0.10 to 0.03; p=0.26; Figure 4), and 5 or more years (RD=−0.01; 95% CI, −0.10 to 0.07; p=0.77; Figure 4). Analysis of heterogeneity revealed that data were heterogeneous at 12 to 18 months, 24 to 30 months, and 3-year follow-ups (p<0.03; I2>45%; Figures 3 and 4) but not at the 5-year recall (p=0.28; I2=21%; Figure 4).



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L
Marginal Discoloration—This analysis was based on 22 studies.i In the overall analysis, which took into consideration both subgroups, no significant difference between the two groups was detected in the follow-ups of 12 to 18 months (RD=−0.02; 95% CI, −0.04 to 0.00; p=0.07; Figure 5), 24 to 30 months (RD=−0.04; 95% CI, −0.10 to 0.02; p=0.18; Figure 5), or 3 years (RD=0.01; 95% CI, −0.06 to 0.09; p=0.75; Figure 5). Analysis of heterogeneity revealed that data were heterogeneous at 12 to 18 months (p=0.16; I2=22%; Figure 5), and 3-year follow-up (p=0.84; I2=0%; Figure 6) but not at the 24 to 30 months recall (p,0.0002; I2=69%; Figure 5).



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L
Secondary Caries—This analysis was based on 17 studies.j In the overall analysis, which took into consideration both subgroups, no significant difference between groups was detected in the follow-ups of 12 to 18 months (RD=−0.00; 95% CI, −0.01 to 0.01; p=0.88; Figure 7), 24 to 30 months (RD=−0.00; 95% CI, −0.02 to 0.01; p=0.59; Figure 7), or 3 years (RD=−0.02; 95% CI, −0.06 to 0.01; p=0.16; Figure 8). Analysis of heterogeneity revealed that data were not heterogeneous at any given recall time (p>0.32; I2<13%; Figures 7 and 8).



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L



Citation: Operative Dentistry 46, 1; 10.2341/19-252-L
Assessment of the Quality of Evidence—In the summary of findings in Table 4, we can observe that for the outcome variable loss of retention, most of the follow-ups were graded as having a low quality of evidence, except for 5 or more year recalls, which were graded as moderate. Unclear risk of bias and unexplained heterogeneity were the reasons for downgrading the level of evidence. For the outcome variable marginal discoloration, the 12- to 18-month recall and the 3-year recall were graded as moderate (unclear risk of bias of the eligible studies) and the 24- to 30-month recall was graded as having a low quality of evidence (unclear risk of bias and unexplained heterogeneity). All meta-analyses of the outcome variable secondary caries were graded as moderate because of the unclear risk of bias of the studies.
DISCUSSION
Systematic reviews and meta-analyses are important for resolving controversies between clinical trials and to provide clinical input for guidelines that address adequate clinical care delivered by oral health personnel, especially general practitioners.110 According to the results of the present study, the addition of fillers or nanofillers in adhesive systems does not significantly improve the clinical performance of the retention rate, marginal discoloration, or secondary caries.
When the first filled adhesive systems emerged in the market, the theoretical concept was that filled adhesive systems act as thickening agents within the adhesive layer. The formation of a thick layer of adhesive interface will improve the mechanical properties, and15,16 according to the so-called elastic bonding concept,17,18 the adhesive layer should absorb the compression produced by the tooth-flexure stress, thus reducing interfacial stresses and preserving the marginal integrity,17,18,111 which eventually should result in better retention rate of the adhesively bonded restorations.12,13
There are, however, options to increase the thickness of the adhesive layer: first, to apply two layers of adhesive, and second, to use a separate hydrophobic layer such as the three-step etch-and-rinse or two-step self-etch adhesive systems.8,112 Some systematic reviews came to the conclusion that simplified adhesive systems such as the one-step self-etch systems reduce the retention rates and increase marginal discoloration of Class V composite resin restorations.8,113 However, a closer view of the RCTs of the present study showed that although 16 studies evaluated filled vs unfilled adhesives, only a few compared a filled or unfilled adhesive within the same adhesive system group.k This prevented us from investigating this variable by a subgroup analysis or meta-regression.
It is worthwhile to mention that flowable composites are also used with the goal of absorbing occlusal stress (“elastic bonding concept”).17,18 However, several systematic reviews have shown that the use of flowable resin composite compared with high-viscous resin composites did not affect the retention rate or marginal discoloration of Class V restorations.8,113,116 Microfillers in adhesive systems (1–5 μm) do not penetrate into the interfibrillar spaces but are observed within the adhesive layer.117 Therefore, there are adhesive systems with glass particles of 20-nm size or lower (pure silicon dioxide, from either colloidal or pyrogenic origin).26,29 According to the manufacturers, the nanofillers are small enough to penetrate into dentin tubules and infiltrate the interfibrillar spaces of demineralized dentin. Furthermore, it was suggested that infiltration of the interfibrillar channels could provide a strengthening element for demineralized dentin.16,27
However, the nanofillers must be physically and chemically stabilized to prevent them from aggregating during storage and/or during the application of the adhesive, which makes these “filler clusters” too large to infiltrate the interfibrillar spaces.27,118 However, several studies showed that no nanofiller had been found inside the hybrid layer or the demineralized dentin.27,119,120 Furthermore, it has been reported that exposed collagen may function as a filter121 that does not allow the nanofillers to penetrate. The molecular weight of the nanofillers and the resin monomers of the adhesives differ substantially. Therefore, the diffusion rate is very different, which inhibits the complete infiltration of the nanofillers into the interfibrillar space.27,122 Some authors claim that in demineralizing dentin, there is a formation of a hydrogel of residual substance, proteoglycans, and noncollagenous proteins that may physically impede the infiltration of nanofillers.123
Also due to the natural tendency to aggregate, micrometric electrodense filler clusters will form that are larger than the interfibrillar spaces.16,27 Osorio and others119 showed that in self-etch adhesive systems, large clusters were observed that were beyond the dimensions of the interfibrillar spaces of the collagen fibers. Some authors suggested that if the volume of the nanofillers within the adhesive was lower than 3.0 wt%, they did not aggregate that easily and would increase the bond strength to dentin.124 However, in commercial simplified etch-and-rinse and self-etch adhesives, more than 5 wt% is found.16 On the other hand, the lower amount of nanofillers did not significantly improve the mechanical properties of the adhesive layer.20,30,31 Other researchers used specific techniques to produce nonaggregated nanoparticles with high antimicrobial potential.125,126 These facts may also explain why no significant increase in the bond strength to dentin could be observed when nanofilled-containing simplified adhesives had been tested compared with unfilled simplified adhesives.32–35
The results of the present study should be interpreted with caution because they represent an overall comparison without taking into consideration specific variations in the products (monomer and solvent composition, application technique, evaporation solvent time, and moisture control). However, if one of these factors has an important role in the clinical performance of an adhesive, merging studies in a meta-analysis will increase the power to detect the role of such a variable. This would not be possible in primary studies with low sample sizes.
Also, the inadequate randomization of some clinical studies may have led to the fact that the chances of a patient being allocated to the test or control group were not the same for all patients, and known and unknown prognostic factors had not been balanced out among the groups.47,110,127 The random sequence should be protected until implementation127 (allocation concealment). Most of the eligible studies that had been included in this systematic review were classified as having unclear risk of bias. This judgment was based on the lack of clear description of the randomization and allocation concealment process. This is in accordance with what was recently published by Reis and others in 2018,128 who reported that more than 60% of RCTs about adhesive systems that had been tested in noncarious cervical lesions had a high or unclear risk of bias for randomization and allocation concealment.
Therefore, long-term and well-conducted RCTs that comply with the requirements of an RCT are needed to evaluate possible technological improvements of adhesive systems such as the addition of nanofillers to improve the longevity of the bonding interface to dentin.
CONCLUSIONS
The addition of micro or nanofillers to the composition of adhesive systems did not increase the clinical performance (retention rates, marginal discoloration, or secondary caries) in noncarious cervical lesions compared with unfilled adhesive systems.

Flowchart diagram showing the number of articles obtained in the different phases of the study.

Summary of the risk of bias assessment for the 27 studies included in the meta-analysis according to the Cochrane Collaboration tool. The risk of bias tool contains six domains: sequence generation, allocation concealment, blinding of the outcome assessors, incomplete outcome data, selective outcome reporting, and other possible sources of bias. Each domain was judged to be at low, unclear, or high risk of bias according to the Cochrane Handbook for Systematic Reviews of Interventions 5.1.0

Forest plot of restorations that suffered retention loss comparing filled/nanofilled vs unfilled adhesives at 12 to 18 months and 24 to 30 months.

Forest plot of restorations that suffered retention loss comparing filled vs unfilled adhesives at 3 and 5 or more years.

Forest plot of restorations with marginal discoloration comparing filled/nanofilled vs unfilled adhesives at 12 to 18 months and 24 to 30 months.

Forest plot of restorations with marginal discoloration comparing filled vs unfilled adhesives at 3 years.

Forest plot of restorations with secondary caries comparing filled/nanofilled vs unfilled adhesives at 12 to 18 months and 24 to 30 months.

Forest plot of restorations with secondary caries comparing filled vs unfilled adhesives at 3 years.
Contributor Notes
Juliana L de Geus, Department of Dentistry, Paulo Picanço School of Dentistry, Fortaleza, CE, Brazil
Bianca M Maran, Department of Dentistry, State University of Ponta Grossa, PR, Brazil
Karla A Cabral, Department of Dentistry, Paulo Picanço School of Dentistry, Fortaleza, CE, Brazil
Andres Dávila-Sánchez, Professor, Departamento de Odontología Restauradora y Biomateriales, Colegio de Ciencias de la Salud, Escuela de Odontología, Universidad San Francisco de Quito USFQ, Quito, Ecuador
Chane Tardem, School of Dentistry, Federal Fluminense University, Rio de Janeiro, RJ, Brazil
Marcos O Barceleiro, School of Dentistry, Federal Fluminense University, Rio de Janeiro, RJ, Brazil
Siegward D Heintze, Research & Development, Ivoclar Vivadent, Schaan, Liechtenstein
Alessandra Reis, Department of Dentistry, State University of Ponta Grossa, PR, Brazil
*Alessandro D Loguercio, Department of Dentistry, State University of Ponta Grossa, PR, Brazil