Vertical Marginal Discrepancy Performance of a CAD-CAM System with Multiple Users

and
Page Range: E273 – E282
DOI: 10.2341/21-204-L
Save
Download PDF

SUMMARY

Purpose

The purpose of this evaluation was to evaluate the vertical marginal discrepancies of a computer-aided design-computer-aided manufacture (CAD-CAM) system used by different providers at separate time intervals.

Methods and Materials

Lithium disilicate monolithic crowns on mandibular third molars were fabricated by three different providers inexperienced in digital dentistry. Using a precision rotary stage mounted on a digital recording microscope, the crown vertical marginal discrepancy was assessed using 160× magnification at 5-degree intervals around the crown marginal circumference for a total of 72 measurements per specimen. In addition to mean vertical marginal discrepancy, the maximum vertical marginal discrepancy, and its location as well as the percent of closed marginal assessments, were assessed. Mean data was analyzed using Kruskal–Wallis and Dunn post hoc testing at a 95% level of confidence (α=0.05).

Results

The mean marginal vertical discrepancy for all specimens was 21.1 ± 5.5 μm and a significant difference (p=0.0016) existed between groups but with noted wide similarity overlap. No difference (p=0.65) was observed with the mean closed margin percentage, but a significant difference (p=0.0012) existed in the observed maximum marginal discrepancy between groups. The 2-mm axial wall height (AWH), 20-degree total occlusal convergence (TOC) had significantly less (p<0.017) mean vertical marginal discrepancies than the 4-mm AWH, 20-degree TOC, and the 3-mm AWH, 16-degree TOC groups with the remaining groups similar (p>0.147). The plotted location of the specimen’s maximum vertical discrepancy suggests a potential pattern amid the 360-degree margin circumference.

Conclusions

Under the conditions of this study, CAD-CAM-derived monolithic lithium disilicate ceramic crowns fabricated by different clinicians demonstrated mean vertical marginal discrepancy results that were less than the suggested maximum clinically acceptable values. A potential for patterns of marginal discrepancy results was identified and deserves further evaluation. Results should be interpreted with caution as in vitro methodologies vary and do not directly correlate with clinical conditions.

Copyright: 2022
Figure 1.
Figure 1.

Preparation surface area assessment example.


Figure 2.
Figure 2.

Total occlusal convergence assessment example.


Figure 3.
Figure 3.

Digital image of preparation within simulated quadrant archform.


Figure 4.
Figure 4.

Representative vertical margin discrepancy assessment example.


Figure 5.
Figure 5.

Locations of three or more similar-located greatest marginal discrepancies legend: zero degrees is located at the middle of mesial surface margin.


Contributor Notes

*Corresponding author: 770 Rose Street MN454, Lexington, KY 40356; e-mail: h.w.roberts@uky.edu

Clinical Relevance

Digital dentistry methods may possess the potential for producing crowns with mean vertical marginal discrepancies less than the suggested clinical maximum acceptable limits.