Effects of Catalyst Bioproducts on In-Office Whitening: A Randomized, Split-mouth Clinical Analysis
To compare conventional hydrogen peroxide (H2O2) whitening therapy (CT) applied for 45 minutes with a test therapy (TT) containing H2O2 whitening gel and catalyst bioproducts applied for 15 minutes. Thirty patients and their hemiarches were randomly divided into two groups: CT: application of 35% H2O2 three times for 15 minutes; test therapy (TT): based on the prior application of a polycaprolactone scaffold and the addition of 10 mg of peroxidase to the 35% whitening gel (3 drops of thickener, 9 drops of peroxide and 10 mg of peroxidase) for an exposure time of 15 minutes. The two treatments were carried out in three whitening sessions, 7 days apart. The chromatic change (ΔE00) and the bleaching index (ΔWID) were analyzed by spectrophotometry. Spontaneous sensitivity was assessed through a questionnaire, and thermal sensitivity was provoked through thermal stimuli after the three sessions and 14 days later. Esthetic self-perception was also measured using the Orofacial Esthetics Scale before and after each session. After the first session, CT exceeded TT in ΔE00 and ΔWID, whereas they were equal at the other time points. Greater intensity and occurrence of spontaneous sensitivity occurred in the first and second sessions with CT. The CT group experienced thermal sensitivity at higher temperatures than the TT group at all times analyzed. Esthetic self-perception was higher (66.6%) in the TT group. The test therapy can achieve the same whitening effect with less total exposure time and less tooth sensitivity than the conventional technique.SUMMARY
Objectives:
Methods:
Results:
Conclusion:

Protocol for the whitening session (A) patient's arch ready to receive the whitening treatment; (B) application of the light-cured gingival barrier on the entire upper arch; (C) positioning of the scaffold on the study hemi-arch; (D) application of the whitening gel on the entire arch according to the protocol; (E) removal of the scaffold and whitening gel from the test hemi-arch after 15 minutes and reapplication of the whitening gel on the conventional hemi-arch; (F) completion of the whitening session).

CONSORT flowchart of the study design.

Perceptibility and acceptability data for the ΔE00 differences between the treatment groups.

Perceptibility and acceptability data for the ΔWID differences between the treatment groups.

Differences in thermal sensation threshold values in relation to baseline (°C). Different uppercase letters between rows and lowercase letters across columns indicate statistically significant differences between treatment groups and times, respectively (p<0.05).
Contributor Notes